The incidence of atrial fibrillation detected by implantable loop recorders: a comparison between patients with and without embolic stroke of undetermined source

被引:0
作者
Chousou, Panagiota A. [1 ,2 ]
Chattopadhyay, Rahul K. [1 ,2 ]
Matthews, Gareth [1 ,3 ]
Clark, Allan [1 ]
Vassiliou, Vassilios S. [1 ,3 ]
Pugh, Peter J. [1 ,2 ]
机构
[1] Univ East Anglia, Norwich Med Sch, Norwich NR4 7TJ, Norfolk, England
[2] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Dept Cardiol, Hills Rd, Cambridge CB2 0QQ, England
[3] Norfolk & Norwich Univ Hosp NHS Fdn Trust, Dept Cardiol, Norwich NR4 7UY, England
来源
EUROPEAN HEART JOURNAL OPEN | 2024年 / 4卷 / 05期
关键词
Atrial fibrillation; Stroke; Incidence; Syncope; Palpitations; Implantable loop recorder; INSERTABLE CARDIAC MONITORS; HIGH-RATE EPISODES; CRYPTOGENIC STROKE; RISK; PREVENTION; PREVALENCE; MANAGEMENT;
D O I
10.1093/ehjopen/oeae061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Stroke is the most debilitating outcome of atrial fibrillation (AF). The use of implantable loop recorders increases the detection of AF episodes among patients with embolic stroke of undetermined source. The significance of device-detected AF, or subclinical AF, is unknown. This study aimed to compare the incidence of AF detected by implantable loop recorder in patients with and without embolic stroke of undetermined source. Methods and results We retrospectively studied all patients without known AF who were referred to our institution for implantable loop recorder implantation following embolic stroke of undetermined source, syncope, or palpitations from March 2009 to November 2019. The primary endpoint was any detection of AF or atrial flutter by implantable loop recorder. Seven hundred and fifty patients were included and followed up for a mean duration of 731 days (SD 443). An implantable loop recorder was implanted following embolic stroke of undetermined source in 323 and for assessment of syncope, palpitations, or another reason in 427 patients. The incidence of AF was significantly (P < 0.001) higher among patients with embolic stroke of undetermined source compared with the non-embolic stroke of undetermined source group; 48.6% vs. 13.8% (for any duration of AF) and 32.2% vs. 12.4% (for AF lasting >= 30 s) both P < 0.001. Kaplan-Meier analysis showed significantly higher incidence of AF for incremental durations of AF up to >5.5 h, but not >24 h. This was driven by longest AF durations of <6 min and between 5.5 h and 24 h, suggesting a bimodal distribution. In a multivariable Cox regression analysis, embolic stroke of undetermined source independently conferred an almost 5-fold increase in the hazard for any duration of AF. Conclusion The incidence of AF is significantly higher amongst embolic stroke of undetermined source vs. non-embolic stroke of undetermined source patients monitored constantly by an implantable loop recorder. A high number of embolic stroke of undetermined source survivors have short-duration AF episodes. Further work is needed to determine the optimal treatment strategy of these AF episodes in embolic stroke of undetermined source. [GRAPHICS] .
引用
收藏
页数:10
相关论文
共 43 条
[1]   Prevalence of atrial fibrillation with insertable cardiac monitors in cryptogenic stroke: A single-center experience [J].
Asaithambi, Ganesh ;
Monita, Jane E. ;
Annamalai, M. Ramu ;
Ho, Bridget M. ;
Marino, Emily H. ;
Hanson, Sandra K. .
JOURNAL OF ELECTROCARDIOLOGY, 2018, 51 (06) :973-976
[2]   Device-detected atrial fibrillation and risk for stroke: an analysis of &gt; 10 000 patients from the SOS AF project (Stroke preventiOn Strategies based on Atrial Fibrillation information from implanted devices) [J].
Boriani, Giuseppe ;
Glotzer, Taya V. ;
Santini, Massimo ;
West, Teena M. ;
De Melis, Mirko ;
Sepsi, Milan ;
Gasparini, Maurizio ;
Lewalter, Thorsten ;
Camm, John A. ;
Singer, Daniel E. .
EUROPEAN HEART JOURNAL, 2014, 35 (08) :508-516
[3]   Temporal Relationship Between Subclinical Atrial Fibrillation and Embolic Events [J].
Brambatti, Michela ;
Connolly, Stuart J. ;
Gold, Michael R. ;
Morillo, Carlos A. ;
Capucci, Alessandro ;
Muto, Carmine ;
Lau, Chu P. ;
Van Gelder, Isabelle C. ;
Hohnloser, Stefan H. ;
Carlson, Mark ;
Fain, Eric ;
Nakamya, Juliet ;
Mairesse, Georges H. ;
Halytska, Marta ;
Deng, Wei Q. ;
Israel, Carsten W. ;
Healey, Jeff S. .
CIRCULATION, 2014, 129 (21) :2094-2099
[4]  
Calkins H, 2017, HEART RHYTHM, V14, pE275, DOI [10.1093/europace/eux275, 10.1093/europace/eux274, 10.1016/j.hrthm.2017.05.012]
[5]   Atrial high-rate episodes and stroke prevention [J].
Camm, A. John ;
Simantirakis, Emmanuel ;
Goette, Andreas ;
Lip, Gregory Y. H. ;
Vardas, Panos ;
Calvert, Melanie ;
Chlouverakis, Gregory ;
Diener, Hans-Christoph ;
Kirchhof, Paulus .
EUROPACE, 2017, 19 (02) :169-179
[6]   The predictive value of abnormal P-wave axis for the detection of incident atrial fibrillation: A systematic review with meta-analysis [J].
Chattopadhyay, Rahul Kumar ;
Chousou, Panagiota Anna ;
Mukherjee, Trisha ;
Pugh, Peter John ;
Vassiliou, Vassilios S. .
PLOS ONE, 2022, 17 (12)
[7]   Atrial fibrillation in embolic stroke of undetermined source: role of advanced imaging of left atrial function [J].
Chousou, Panagiota Anna ;
Chattopadhyay, Rahul ;
Ring, Liam ;
Khadjooi, Kayvan ;
Warburton, Elizabeth A. ;
Mukherjee, Trisha ;
Bhalraam, U. ;
Tsampasian, Vasiliki ;
Potter, John ;
Perperoglou, Aris ;
Pugh, Peter John ;
Vassiliou, Vassilios S. .
EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2023, 30 (18) :1965-1974
[8]   Electrocardiographic Predictors of Atrial Fibrillation [J].
Chousou, Panagiota Anna ;
Chattopadhyay, Rahul ;
Tsampasian, Vasiliki ;
Vassiliou, Vassilios S. ;
Pugh, Peter John .
MEDICAL SCIENCES, 2023, 11 (02)
[9]   Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke [J].
Cotter, Paul E. ;
Martin, Peter J. ;
Ring, Liam ;
Warburton, Elizabeth A. ;
Belham, Mark ;
Pugh, Peter J. .
NEUROLOGY, 2013, 80 (17) :1546-1550
[10]   Ultra-early continuous cardiac monitoring improves atrial fibrillation detection and prognosis of patients with cryptogenic stroke [J].
Cuadrado-Godia, E. ;
Benito, B. ;
Ois, A. ;
Valles, E. ;
Rodriguez-Campello, A. ;
Giralt-Steinhauer, E. ;
Cabrera, S. ;
Alcalde, O. ;
Jimenez-Lopez, J. ;
Jimenez-Conde, J. ;
Marti-Almor, J. ;
Roquer, J. .
EUROPEAN JOURNAL OF NEUROLOGY, 2020, 27 (02) :244-250