Exploration of comprehensive two-dimensional liquid chromatography : Theoretical aspects and practical considerations-A tutorial

被引:0
作者
Arena, Katia [1 ]
Cacciola, Francesco [1 ]
Vinci, Roberto Lagana
Dugo, Paola [1 ,2 ]
Mondello, Luigi [1 ,2 ]
机构
[1] Univ Messina, Messina Inst Technol MeIT, Former Vet Sch, Dept Chem Biol Pharmaceut & Environm Sci, I-98168 Messina, Italy
[2] Univ Messina, Former Vet Sch, Chromaleont srl, Dept Chem Biol Pharmaceut & Environm Sci, I-98168 Messina, Italy
来源
JOURNAL OF CHROMATOGRAPHY OPEN | 2025年 / 7卷
关键词
LCxLC; Multidimensional chromatography; Complex samples; method optimization; EFFECTIVE PEAK-CAPACITY; REVERSED-PHASE SEPARATIONS; TANDEM MASS-SPECTROMETRY; ORTHOGONALITY; COLUMN; RESOLUTION; SYSTEMS; MODULATION; IDENTIFICATION; 2ND-DIMENSION;
D O I
10.1016/j.jcoa.2025.100222
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Comprehensive two-dimensional liquid chromatography (LCxLC) is a valuable tool for the analysis of very complex samples. LCxLC, which involves the coupling of two or more orthogonal separation systems, is a potential alternative to the conventional liquid-chromatography (1D-LC) approach. The profits of such a technique, compared to the 1D-LC approach, are the increased resolving power along with significant reduced ion enhancement or suppression phenomena in the MS source. This tutorial aims to provide detailed information on theoretical and practical aspects of the LCxLC approach with a particular focus on column combination, method optimization and separation performance. In addition, future perspectives and new trends are highlighted.
引用
收藏
页数:16
相关论文
共 97 条
[1]   Two-dimensional liquid chromatography with reversed phase in both dimensions: A review [J].
Aly, Alshymaa A. ;
Gorecki, Tadeusz .
JOURNAL OF CHROMATOGRAPHY A, 2024, 1721
[2]   Enhancing detectability of anabolic-steroid residues in bovine urine by actively modulated online comprehensive two-dimensional liquid chromatography - high-resolution mass spectrometry [J].
Baglai, Anna ;
Blokland, Marco H. ;
Mol, Hans G. J. ;
Gargano, Andrea F. G. ;
van der Wal, Sjoerd ;
Schoenmakers, Peter J. .
ANALYTICA CHIMICA ACTA, 2018, 1013 :87-97
[3]   A theoretical basis for parameter selection and instrument design in comprehensive size-exclusion chromatography x liquid chromatography [J].
Bedani, Filippo ;
Kok, Wim Th. ;
Janssen, Hans-Gerd .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1133 (1-2) :126-134
[4]   Kinetic plot based comparison of the efficiency and peak capacity of high-performance liquid chromatography columns: Theoretical background and selected examples [J].
Broeckhoven, Ken ;
Cabooter, Deirdre ;
Eeltink, Sebastiaan ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1228 :20-30
[5]  
Buckenmaier S., 2015, Chromatogr Today, P20, DOI [10.1002/mas.21845, DOI 10.1002/MAS.21845]
[6]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[7]   Reversed phase versus hydrophilic interaction liquid chromatography as first dimension of comprehensive two-dimensional liquid chromatography systems for the elucidation of the polyphenolic content of food and natural products [J].
Cacciola, Francesco ;
Arena, Katia ;
Mandolfino, Filippo ;
Donnarumma, Danilo ;
Dugo, Paola ;
Mondello, Luigi .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1645
[8]   Comprehensive two-dimensional liquid chromatography as a powerful tool for the analysis of food and food products [J].
Cacciola, Francesco ;
Rigano, Francesca ;
Dugo, Paola ;
Mondello, Luigi .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 127
[9]   Multidimensional liquid chromatography in food analysis [J].
Cacciola, Francesco ;
Dugo, Paola ;
Mondello, Luigi .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 96 :116-123
[10]   Comprehensive Liquid Chromatography and Other Liquid-Based Comprehensive Techniques Coupled to Mass Spectrometry in Food Analysis [J].
Cacciola, Francesco ;
Donato, Paola ;
Sciarrone, Danilo ;
Dugo, Paola ;
Mondello, Luigi .
ANALYTICAL CHEMISTRY, 2017, 89 (01) :414-429