Diagnostic Value of Superparamagnetic Iron Oxide Nanoparticles as a Tracer for Sentinel Lymph Node Mapping in Early-Stage Cervical Cancer: The Preliminary Clinical Experience

被引:0
作者
Jedryka, Marcin A. [1 ,2 ]
Czekanski, Andrzej [1 ,2 ]
Kryszpin, Marcin [2 ]
Poprawski, Tymoteusz [2 ]
Grobelak, Krzysztof [2 ]
Lepka, Piotr [1 ,2 ]
Matkowski, Rafal [1 ,3 ]
机构
[1] Wroclaw Med Univ, Fac Med, Dept Oncol, PL-50367 Wroclaw, Poland
[2] Lower Silesian Oncol Hematol & Pulmonol Ctr, Dept Oncol Gynecol, PL-53413 Wroclaw, Poland
[3] Lower Silesian Oncol Pulmonol & Hematol Ctr, Breast Canc Clin, PL-53413 Wroclaw, Poland
关键词
sentinel lymph node; tracer; mapping; lymphadenectomy; cervical cancer; superparamagnetic iron oxide; nanoparticle; RADICAL HYSTERECTOMY; BIOPSY; IDENTIFICATION; COMPLICATIONS; MULTICENTER; MANAGEMENT; SENTIMAG; WOMEN; TRIAL; RISK;
D O I
10.3390/jfb16060196
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Sentinel lymph node (SLN) mapping has been investigated as part of surgical staging in women with early-stage cervical cancer (CC); however, pelvic lymphadenectomy (PLND) remains the standard of care. This study aimed to assess feasibility and safety of SLN detection using superparamagnetic iron oxide (SPIO) nanoparticles as a tracer in CC. Thirty CC patients presumed to be stage I were included in this study with SPIO administered intracervically as a tracer for SLN mapping using a magnetometer and followed by PLND. The endpoints of the study included the proportion of successful SLN detection, the average number of SLNs per patient, and the proportion of pathologically positive results per patient and per node. The diagnostic accuracy of SPIO nanoparticles for detection of metastatic SLNs was evaluated by Receiver Operating Characteristic (ROC) curve analysis, with the area under the ROC curve (AUC) used to demonstrate the studied method's sensitivity. Safety endpoints were a summary of all reported adverse events. SLNs were detected in all cases, bilaterally in 27 patients (90%). The median number of SLNs per patient was 3.5. Four cases had metastatic SLNs. The general malignancy rate per patient was 13.3%, and per node, it was 0.8%. The malignancy detection rate of SLNs was 100% per patient and 80% per node. The AUC of 1.0 (p < 0.001) confirmed the diagnostic value of the SPIO technique for the detection of metastatic SLNs, with a sensitivity of 100%. No adverse events related to the SPIO administration were reported. SPIO nanoparticles, as a tracer for SLN mapping in early-stage CC patients, demonstrated satisfactory accuracy parameters and safety; however, these data need to be evaluated by further research.
引用
收藏
页数:14
相关论文
共 46 条
[41]   Sentinel lymph node biopsy in patients with breast cancer using superparamagnetic iron oxide and a magnetometer [J].
Shiozawa, Mikio ;
Lefor, Alan T. ;
Hozumi, Yasuo ;
Kurihara, Katsumi ;
Sata, Naohiro ;
Yasuda, Yoshikazu ;
Kusakabe, Moriaki .
BREAST CANCER, 2013, 20 (03) :223-229
[42]   Sentinel lymph node assessment in endometrial cancer: a systematic review and meta-analysis [J].
Smith, Anna Jo Bodurtha ;
Fader, Amanda Nickles ;
Tanner, Edward J. .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (05) :459-+
[43]   The sentinel node procedure in early stage cervical cancer, taking the next step; a diagnostic review [J].
Tax, Casper ;
Rovers, Maroeska M. ;
de Graaf, Corine ;
Zusterzeel, Petra L. M. ;
Bekkers, Ruud L. M. .
GYNECOLOGIC ONCOLOGY, 2015, 139 (03) :559-567
[44]   The Central-European SentiMag study: Sentinel lymph node biopsy with superparamagnetic iron oxide (SPIO) vs. radioisotope [J].
Thill, Marc ;
Kurylcio, Andrzej ;
Welter, Rebekka ;
van Haasteren, Viviana ;
Grosse, Britta ;
Berclaz, Gilles ;
Polkowski, Wojciech ;
Hauser, Nik .
BREAST, 2014, 23 (02) :175-179
[45]   Accuracy of Magnetometer-Guided Sentinel Lymphadenectomy after Intraprostatic Injection of Superparamagnetic Iron Oxide Nanoparticles in Prostate Cancer: The SentiMag Pro II Study [J].
Winter, Alexander ;
Engels, Svenja ;
Goos, Philipp ;
Sueykers, Marie-Christin ;
Gudenkauf, Stefan ;
Henke, Rolf-Peter ;
Wawroschek, Friedhelm .
CANCERS, 2020, 12 (01)
[46]   Magnetic resonance sentinel lymph node imaging and magnetometer-guided intraoperative detection in prostate cancer using superparamagnetic iron oxide nanoparticles [J].
Winter, Alexander ;
Kowald, Tobias ;
Paulo, Tina Susanne ;
Goos, Philipp ;
Engels, Svenja ;
Gerullis, Holger ;
Schiffmann, Onas ;
Chavan, Ajay ;
Wawroschek, Friedhelm .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2018, 13 :6689-6698