Gait assessment using a 2D video-based motion analysis app in healthy subjects and subjects with lower limb amputation - A pilot study

被引:0
作者
Doerks, Frithjof [1 ]
Harms, Fenna [1 ]
Schwarze, Michael [1 ,2 ]
Jakubowitz, Eike [1 ]
Welke, Bastian [1 ]
机构
[1] Hannover Med Sch, Dept Orthopaed Surg, Lab Biomech & Biomat, DIAKOVERE Annastift, Hannover, Germany
[2] Bremerhaven Univ Appl Sci, Dept Med Technol, Bremerhaven, Germany
关键词
LOWER-EXTREMITY; WALKING; PERFORMANCE; TECHNOLOGY; KINEMATICS;
D O I
10.1371/journal.pone.0324499
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction Although three-dimensional marker-based motion analysis is the gold standard for biomechanical investigations, it is time-consuming and cost-intensive. The conjunction of monocular video recordings with pose estimation algorithms addresses this gap. With the Orthelligent VISION app (OPED GmbH) a commercial and easy-to-use tool is now available for implementation in everyday clinical practice. The study investigates the accuracy of the 2D video-based system in measuring joint kinematics, expressed as range of motion, compared to an optoelectronic 3D motion analysis system as the gold standard.Materials and methods Its accuracy was determined by synchronously measuring ten healthy subjects with Orthelligent and the optoelectronic 3D motion analysis system Qualisys (Qualisys AB) during level walking and at different treadmill walking speeds (1 m/s; 1.4 m/s; 1.8 m/s). Range of motion (RoM) of lower limb joints and time-distance parameters were compared using Bland-Altman plots, t-tests, and correlations between systems. Kinematic outputs of two subjects with a lower limb amputation were also analyzed.Results The mean RoM deviation was smaller for the knee (3.8 degrees) and hip joints (3.7 degrees) than for the ankle joint (5.4 degrees), but differed significantly between systems in most conditions. The correlation range was 0.36 <= r <= 0.83, with best results for 1 m/s treadmill walking (mean r = 0.71 across joints). While the accuracy was affected by high inter-subject variability, individual RoM changes from slow to fast walking did not differ between the systems. The kinematics of the prosthetic and sound leg of individuals with an amputation exhibited characteristic patterns in the video-based system, even though side differences were smaller compared to the optoelectronic measurement.Conclusions The rather high inter-subject variability would make future comparisons between individuals challenging. Nonetheless, the app shows potential for intra-subject progress monitoring.
引用
收藏
页数:13
相关论文
共 43 条
[1]   Normal walking speed: a descriptive meta-analysis [J].
Bohannon, Richard W. ;
Andrews, A. Williams .
PHYSIOTHERAPY, 2011, 97 (03) :182-189
[2]   Position paper on how technology for human motion analysis and relevant clinical applications have evolved over the past decades: Striking a balance between accuracy and convenience [J].
Bonato, Paolo ;
Feipel, Veronique ;
Corniani, Giulia ;
Arin-Bal, Gamze ;
Leardini, Alberto .
GAIT & POSTURE, 2024, 113 :191-203
[3]   Knee Kinematic and Clinical Outcomes Evolution Before, 3 Months, and 1 Year After Total Knee Arthroplasty [J].
Bonnefoy-Mazure, Alice ;
Armand, Stephane ;
Sagawa, Yoshisama, Jr. ;
Suva, Domizio ;
Miozzari, Hermes ;
Turcot, Katia .
JOURNAL OF ARTHROPLASTY, 2017, 32 (03) :793-800
[4]   A comparison of lower body gait kinematics and kinetics between Theia3D markerless and marker-based models in healthy subjects and clinical patients [J].
D'Souza, Sonia ;
Siebert, Tobias ;
Fohanno, Vincent .
SCIENTIFIC REPORTS, 2024, 14 (01)
[5]   Relationship Between Transverse -plane Kinematic Deviations of Lower Limbs and Gait Performance in Children with Unilateral Cerebral Palsy: A Descriptive Analysis [J].
Elnaggar, Ragab K. .
GAIT & POSTURE, 2020, 79 :224-228
[6]   Sampling rate influences the regularity analysis of temporal domain measures of walking more than spatial domain measures [J].
Fallahtafti, Farahnaz ;
Wurdeman, Shane R. ;
Yentes, Jennifer M. .
GAIT & POSTURE, 2021, 88 :216-220
[7]  
Greitemann B, 2017, Z ORTHOP UNFALLCHIR, V155, P737, DOI 10.1055/s-0043-110774
[8]   Establishing the Minimal Clinically Important Differences for Sagittal Hip Range of Motion in Chronic Stroke Patients [J].
Guzik, Agnieszka ;
Druzbicki, Mariusz ;
Perenc, Lidia ;
Wolan-Nieroda, Andzelina ;
Turolla, Andrea ;
Kiper, Pawel .
FRONTIERS IN NEUROLOGY, 2021, 12
[9]   Estimating Minimal Clinically Important Differences for Knee Range of Motion after Stroke [J].
Guzik, Agnieszka ;
Druzbicki, Mariusz ;
Wolan-Nieroda, Andzelina ;
Turolla, Andrea ;
Kiper, Pawel .
JOURNAL OF CLINICAL MEDICINE, 2020, 9 (10) :1-14
[10]  