Improved Efficiency of Magnetic Field Contactless Power Transfer using Relay Circuit with Resonant Frequency Different from Power Supply Frequency

被引:0
作者
Masaru I. [1 ]
Masashi O. [2 ]
机构
[1] Graduate School of Engineering, Chiba Institute of Technology, 2-17-1, Tsudanuma, Narashino
[2] Faculty of Engineering, Chiba Institute of Technology, 2-17-1, Tsudanuma, Narashino
关键词
magnetic field coupling type contactless power supply; resonant circuit; sensor network;
D O I
10.1541/ieejfms.144.237
中图分类号
学科分类号
摘要
In this study, a relay resonance circuit is used transmitted power to the sensor module using four-parallel cubic coils, and the efficiency decrease with the change in the transmission distance is investigated experimentally. The relay resonant circuit used was examined for resonant frequencies that were near the usable frequency. A square coil was used as the receiving coil. Using Vector Network Analyzer (VNA), the S-parameters were measured with the transmitting and receiving coils as 2 ports, and after converting the S-parameters to Z-parameters, the theoretical maximum efficiency ηmax was calculated. The distance variation characteristics using each relay resonance circuit were investigated. As a result, it was found that the theoretical maximum efficiency was improved when relay coils were used, and that the theoretical maximum efficiency tended to increase when the resonance frequency was slightly larger than the frequency of the power supply circuit. © 2024 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:237 / 244
页数:7
相关论文
共 13 条
[1]  
Zeng Y., Qiu D., Meng X., Zhang B., Tang S.C., Optimized Design of Coil for Wireless Power Transfer in Inimplant Medical Devices, IEEE J. Electromag., RF and Microwaves in Medicine and Biology, 2, 4, pp. 277-285, (2018)
[2]  
Li W., Zhu J., Wang Y., Liu B., Modeling and Characteristic Analysis of Magnetic Coupling Mechanism in Seawater Environment, IEEE Trans. Magn, 58, 9, pp. 1-6, (2022)
[3]  
Drozd S., Smid R., Short-Range Wirelessly Powered Sensor Network: Concept and Initial Measurement, 2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), pp. 1-5, (2020)
[4]  
Ohchi M., Muramatsu R., Furukawa T., Fukumoto H., Numerical Electromagnetic Analysis of Magnetic Coupling Type Non-contact Power Supply Using Cylindrical 3 Axis Basket Coil, IEICE, J105-B, 3, pp. 355-361, (2022)
[5]  
Ikuma N., Ohchi M., Experimental Study of Transmission Coil Configuration for Omnidirectional Power Transfer in Magnetic Field Coupling Type Contactless Power Transfer, IEEJ Trans. FM, 143, 4, pp. 115-122, (2023)
[6]  
Koh K.E., Beh T.C., Imura T., Hori Y., Impedance Matching and Power Division Using Impedance Inverter for Wireless Power Transfer via Magnetic Resonant Coupling, IEEE Trans. Industr. Applic, 50, 3, pp. 2061-2070, (2014)
[7]  
Imura T., Equivalent Circuits of Repeater Antennas for Wireless Power Transfer via Magnetic Resonant Coupling, IEEJ Trans. IA, 131, 12, pp. 1373-1382, (2011)
[8]  
ROHDE&SCHWARZ ZNL/ZNLE Vector Network Analyzers User Manual
[9]  
Ohira T., Maximum available efficiency formulation based on a black-box model of linear two-port power transfer systems, 11, 13, (2014)
[10]  
(2017)