Interactions of contact force, impedance, and power during repeated atrial arrhythmia ablation after previous atrial fibrillation ablation

被引:0
作者
Alken, Fares-Alexander [1 ]
Scherschel, Katharina [1 ,2 ]
Zhu, Ernan [1 ]
Wafaisade, Bahram [1 ]
Kahle, Ann-Kathrin [1 ,3 ]
Meyer, Christian [1 ,2 ]
机构
[1] EVK Dusseldorf, Div Cardiol Angiol Intens Care, Cardiac Neuroand Electrophysiol Res Grp, cNEP, Dusseldorf, Germany
[2] Heinrich Heine Univ Dusseldorf, Inst Neural & Sensory Physiol, CNEP Cardiac Neuro & Electrophysiol Res Consortium, Med Fac, Dusseldorf, Germany
[3] Univ Hosp Duesseldorf, Fac Med, Dept Med, Div Cardiol Pulmonol & Vasc Med, D-40225 Dusseldorf, Germany
关键词
Atrial arrhythmia; Atrial fibrillation; Atrial tachycardia; Catheter ablation; Contact force; Local impedance; Power; PULSED-FIELD; RADIOFREQUENCY; TRANSMURALITY;
D O I
10.1016/j.hrthm.2024.09.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Acutely effective repeated radiofrequency catheter ablation (RFCA) after previous atrial fibrillation ablation depends on several parameters including local impedance (LI), contact force (CF), and power. Objective We aimed to investigate the relationship of LI, CF, and power to the LI drop in a repeated atrial RFCA environment. Methods Consecutive patients undergoing repeated atrial RFCA were studied. High-quality local electrograms were analyzed for morphology changes indicating effective RFCA and associated LI dynamics. The influence of baseline LI, mean CF, and power on the LI drop was analyzed. Investigated power levels included <= 25 W, 30 W, and >= 40 W. Results A total of 1390 RFCA points from 48 patients (48% female; median age, 70 years) were analyzed. Of 309 analyzed electrograms, 40.5% showed effective RFCA morphology changes with an elevated median LI drop (effective, 19.7 Omega; partially effective, 14.1 Omega; P < .001). CF showed the highest correlation to the LI drop within high baseline LI and when applying >= 40 W (low baseline LI, R = 0.39; intermediate, R = 0.66; high, R = 0.72). Within low baseline LI regions, CF levels showed a lower correlation to the LI drop (<= 25 W, R = 0.30; 30 W, R = 0.35; >= 40 W, R = 0.39). A mean CF >= 10 g resulted in elevated LI drops with higher power compared with lower power within all baseline LI tertiles (P < .001 each). Conclusion Within high baseline LI regions, CF plays a greater role for the maximum LI drop when higher power is chosen. A mean CF >= 10 g ensures elevated LI drops with increasing power levels.
引用
收藏
页码:1411 / 1420
页数:10
相关论文
共 21 条
[1]   Combined contact force and local impedance dynamics during repeat atrial fibrillation catheter ablation [J].
Alken, Fares-Alexander ;
Scherschel, Katharina ;
Kahle, Ann-Kathrin ;
Masjedi, Mustafa ;
Meyer, Christian .
FRONTIERS IN PHYSIOLOGY, 2022, 13
[2]   Contemporary management of patients undergoing atrial fibrillation ablation: in-hospital and 1-year follow-up findings from the ESC-EHRA atrial fibrillation ablation long-term registry [J].
Arbelo, Elena ;
Brugada, Josep ;
Blomstrom-Lundqvist, Carina ;
Laroche, Cecile ;
Kautzner, Josef ;
Pokushalov, Evgeny ;
Raatikainen, Pekka ;
Efremidis, Michael ;
Hindricks, Gerhard ;
Barrera, Alberto ;
Maggioni, Aldo ;
Tavazzi, Luigi ;
Dagres, Nikolaos .
EUROPEAN HEART JOURNAL, 2017, 38 (17) :1303-1316
[3]   The influence of electrode-tissue-coverage on RF lesion formation and local impedance: Insights from an ex vivo model [J].
Bahlke, Fabian ;
Wachter, Andreas ;
Erhard, Nico ;
Englert, Florian ;
Krafft, Hannah ;
Popa, Miruna ;
Risse, Elena ;
Kottmaier, Marc ;
Telishevska, Marta ;
Lengauer, Sarah ;
Lennerz, Carsten ;
Reents, Tilko ;
Hessling, Gabriele ;
Deisenhofer, Isabel ;
Bourier, Felix .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (10) :1170-1181
[4]   Determinants of left atrial local impedance: Relationships with contact force, atrial fibrosis, and rhythm [J].
Bates, Alexander P. ;
Paisey, John ;
Yue, Arthur ;
Banks, Phil ;
Roberts, Paul R. ;
Ullah, Waqas .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (06) :1061-1068
[5]  
Calkins H, 2018, EUROPACE, V20, P157, DOI [10.1093/europace/eux275, 10.1093/europace/eux274, 10.1016/j.hrthm.2017.05.012]
[6]   Combined local impedance and contact force for radiofrequency ablation assessment [J].
Garrott, Kara ;
Laughner, Jacob ;
Gutbrod, Sarah ;
Sugrue, Alan ;
Shuros, Allan ;
Sulkin, Matt ;
Yasin, Omar ;
Bush, Jamie ;
Pottinger, Nathan ;
Meyers, Jason ;
Kapa, Suraj .
HEART RHYTHM, 2020, 17 (08) :1371-1380
[7]   A novel assessment of local impedance during catheter ablation: initial experience in humans comparing local and generator measurements [J].
Gunawardene, Melanie ;
Muenkler, Paula ;
Eickholt, Christian ;
Akbulak, Ruken Oe ;
Jularic, Mario ;
Klatt, Niklas ;
Hartmann, Jens ;
Dinshaw, Leon ;
Jungen, Christiane ;
Moser, Julia M. ;
Merbold, Lydia ;
Willems, Stephan ;
Meyer, Christian .
EUROPACE, 2019, 21 :34-42
[8]   Improved Ablation Efficiency in PVI Guided by Contact Force and Local Impedance: Chronic Canine Model [J].
Gutbrod, Sarah R. ;
Shuros, Allan ;
Koya, Vijay ;
Alexander-Curtis, Michelle ;
Lehn, Lauren ;
Miklos, Kimberly ;
Mounsey, John Paul ;
Meyers, Jason D. .
FRONTIERS IN PHYSIOLOGY, 2022, 12
[9]  
HAINES D E, 1991, Journal of Cardiovascular Electrophysiology, V2, P509, DOI 10.1111/j.1540-8167.1991.tb01353.x
[10]   Pulsed Field Ablation of Left Ventricular Myocardium in a Swine Infarct Model [J].
Im, Sung Il ;
Higuchi, Satoshi ;
Lee, Adam ;
Stillson, Carol ;
Buck, Eric ;
Morrow, Blake ;
Schenider, Kit ;
Speltz, Molly ;
Gerstenfeld, Edward P. .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (06) :722-731