Implementation of a novel pencil beam scanning Bragg peak FLASH technique to a commercial treatment planning system

被引:1
作者
Bookbinder, Alexander [1 ,2 ]
Krieger, Miriam [3 ]
Lansonneur, Pierre [3 ]
Magliari, Anthony [3 ]
Zhao, Xingyi [1 ]
Choi, J. Isabelle [1 ]
Simone II, Charles B. [1 ]
Lin, Haibo [1 ]
Folkerts, Michael [3 ]
Kang, Minglei [1 ,4 ]
机构
[1] New York Proton Ctr, New York, NY 10035 USA
[2] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY USA
[3] Varian Med Syst, Palo Alto, CA USA
[4] Univ Wisconsin, Dept Human Oncol, Madison, WI USA
关键词
Bragg peak FLASH Radiotherapy; proton pencil beam scanning; stereotactic body radiation therapy; treatment planning system; PROTON THERAPY; QUALITY; RT;
D O I
10.1002/mp.17876
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundUltra-high dose rate, or FLASH, radiotherapy has shown promise in preclinical experiments of sparing healthy tissue without compromising tumor control. This "FLASH effect" can compound with dosimetric sparing of the proton Bragg peak (BP) using a method called Single Energy Pristine Bragg Peak (SEPBP) FLASH. However, this and other proposed FLASH techniques are constrained by lack of familiar treatment planning systems (TPSs). Creating modules to implement SEPBP FLASH into a commercial TPS opens up the possibility of more widespread investigation of FLASH and lays the groundwork for future clinical translation.PurposeTo implement, investigate, and benchmark the capacity of a commercial TPS research extension for BP FLASH SBRT treatment planning by studying the dosimetric properties and FLASH ratio for critical organs-at-risk (OARs) at several sites.MethodsA 250 MeV clinical proton beam model was commissioned in the Eclipse TPS (Varian Medical Systems, Palo Alto, USA). BP FLASH fields were single-layer maximum-energy beams with a universal range shifter (URS) and field-specific range compensators (RCs). RCs for each beam angle were included as contours within the structure set, while the URS was modeled in the PBS beamline. Spotmaps were created using Lloyd's algorithm with minimum monitor units (MU)-based spacing to ensure plan quality and preserve FLASH coverage for critical OARs. Inverse optimization while preserving minimum MU constraints was done with scorecard-based optimization. Fifteen SBRT cases from three anatomical sites (liver, lung, base-of-skull [BOS]) previously treated at the New York Proton Center were re-optimized using this method, and dosimetric characteristics of BP plans were compared to clinically treated plans. FLASH ratios for critical OARs were evaluated for BP FLASH plans.ResultsThe dose distributions, including target uniformity, conformity index (CI), and DVHs, showed no significant difference in clinically-used metrics between BP FLASH and clinically delivered plans across all anatomical sites. Mean 40 Gy/s FLASH ratios for critical OARs were above 84% for all but one OAR with 2 Gy threshold and above 98% for all OARs with 5 Gy threshold. Dmax for liver and BOS cases was 111.3 +/- 2.68 and 112.88 +/- 1.29, respectively, and D2% for lung cases was 112.04 +/- 1.09. All Dmax remained below 115%.ConclusionsInverse planning using a single-energy BP FLASH technique based on sparse spots and ultra-high minimum MU/spot can achieve intensity-modulated proton therapy (IMPT)-equivalent quality and sufficient FLASH coverage. This successful prototype brings us closer to commercial implementation and may increase the availability of proton FLASH dosimetry studies.
引用
收藏
页数:12
相关论文
共 62 条
[1]   Whole Abdominal Pencil Beam Scanned Proton FLASH Increases Acute Lethality [J].
Bell, Brett I. ;
Velten, Christian ;
Pennock, Michael ;
Kang, Minglei ;
Tanaka, Kathryn E. ;
Selvaraj, Balaji ;
Bookbinder, Alexander ;
Koba, Wade ;
Vercellino, Justin ;
English, Jeb ;
Malachowska, Beata ;
Pandey, Sanjay ;
Duddempudi, Phaneendra K. ;
Yang, Yunjie ;
Shajahan, Shahin ;
Hasan, Shaakir ;
Choi, J. Isabelle ;
Simone, Charles B. ;
Yang, Weng-Lang ;
Tome, Wolfgang A. ;
Lin, Haibo ;
Guha, Chandan .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2025, 121 (02) :493-505
[2]  
Bookbinder A, 2024, INT J RADIAT ONCOL, V120, pE103, DOI 10.1016/j.ijrobp.2024.07.2008
[3]   FLASH Radiotherapy: Expectations, Challenges, and Current Knowledge [J].
Borghini, Andrea ;
Labate, Luca ;
Piccinini, Simona ;
Panaino, Costanza Maria Vittoria ;
Andreassi, Maria Grazia ;
Gizzi, Leonida Antonio .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (05)
[4]   Treatment of a first patient with FLASH-radiotherapy [J].
Bourhis, Jean ;
Sozzi, Wendy Jeanneret ;
Jorge, Patrik Goncalves ;
Gaide, Olivier ;
Bailat, Claude ;
Duclos, Frederic ;
Patin, David ;
Ozsahin, Mahmut ;
Bochud, Francois ;
Germond, Jean-Francois ;
Moeckli, Raphael ;
Vozenin, Marie-Catherine .
RADIOTHERAPY AND ONCOLOGY, 2019, 139 :18-22
[5]   Biological effects in normal cells exposed to FLASH dose rate protons [J].
Buonanno, Manuela ;
Grilj, Veljko ;
Brenner, David J. .
RADIOTHERAPY AND ONCOLOGY, 2019, 139 :51-55
[6]   Travel-Time Disparities in Access to Proton Beam Therapy for Cancer Treatment [J].
Burus, Todd ;
Vanhelene, Alexander D. ;
Rooney, Michael K. ;
Lang Kuhs, Krystle A. ;
Christian, W. Jay ;
Mcnair, Christopher ;
Mishra, Sanjay ;
Paulino, Arnold C. ;
Smith, Grace L. ;
Frank, Steven J. ;
Warner, Jeremy L. .
JAMA NETWORK OPEN, 2024, 7 (05) :E2410670
[7]   FLASH Proton Pencil Beam Scanning Irradiation Minimizes Radiation-Induced Leg Contracture and Skin Toxicity in Mice [J].
Cunningham, Shannon ;
McCauley, Shelby ;
Vairamani, Kanimozhi ;
Speth, Joseph ;
Girdhani, Swati ;
Abel, Eric ;
Sharma, Ricky A. ;
Perentesis, John P. ;
Wells, Susanne I. ;
Mascia, Anthony ;
Sertorio, Mathieu .
CANCERS, 2021, 13 (05) :1-15
[8]   FLASH radiotherapy for the treatment of symptomatic bone metastases in the thorax (FAST-02): protocol for a prospective study of a novel radiotherapy approach [J].
Daugherty, E. c ;
Zhang, Y. ;
Xiao, Z. ;
Mascia, A. e ;
Sertorio, M. ;
Woo, J. ;
Mccann, C. ;
Russell, K. j ;
Sharma, R. a ;
Khuntia, D. ;
Bradley, J. d ;
Simone, C. b ;
Breneman, J. c ;
Perentesis, J. p .
RADIATION ONCOLOGY, 2024, 19 (01)
[9]   FLASH Radiotherapy for the Treatment of Symptomatic Bone Metastases (FAST-01): Protocol for the First Prospective Feasibility Study [J].
Daugherty, Emily C. ;
Mascia, Anthony ;
Zhang, Yong ;
Lee, Eunsin ;
Xiao, Zhiyan ;
Sertorio, Mathieu ;
Woo, Jennifer ;
McCann, Claire ;
Russell, Kenneth ;
Levine, Lisa ;
Sharma, Ricky ;
Khuntia, Deepak ;
Bradley, Jeffrey ;
Simone, Charles B. ;
Perentesis, John ;
Breneman, John .
JMIR RESEARCH PROTOCOLS, 2023, 12 (01)
[10]   Design, Implementation, and in Vivo Validation of a Novel Proton FLASH Radiation Therapy System [J].
Diffenderfer, Eric S. ;
Verginadis, Ioannis I. ;
Kim, Michele M. ;
Shoniyozov, Khayrullo ;
Velalopoulou, Anastasia ;
Goia, Denisa ;
Putt, Mary ;
Hagan, Sarah ;
Avery, Stephen ;
Teo, Kevin ;
Zou, Wei ;
Lin, Alexander ;
Swisher-McClure, Samuel ;
Koch, Cameron ;
Kennedy, Ann R. ;
Minn, Andy ;
Maity, Amit ;
Busch, Theresa M. ;
Dong, Lei ;
Koumenis, Costas ;
Metz, James ;
Cengel, Keith A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 106 (02) :440-448