Polarization-independent ultra-sensitive graphene sensor for the detection of prostate-specific antigen

被引:0
作者
Rafighirani, Yousef [1 ]
Javidan, Javad [1 ]
Heidarzadeh, Hamid [1 ]
机构
[1] Department of Electrical and Computer Engineering, University of Mohaghegh Ardabili, Ardabil
来源
Optik | 2025年 / 322卷
关键词
Biosensor; Graphene heterogeneous structure; Metamaterial; Reflectivity index; Terahertz;
D O I
10.1016/j.ijleo.2024.172196
中图分类号
学科分类号
摘要
This study presents a three-band absorbent structure based on cut graphene, which has been used as a biosensor for the detection of prostate-specific antigen (PSA) due to the tunability of the resonance frequency of graphene and the polarization-independent capability of the proposed structure. The sensor is composed of three layers: a copper substrate with a conductivity of 5.831 ×107, a silicon dioxide (SiO₂) dielectric layer with a permittivity of 3.9, and a graphene layer with strategic cuts to enhance absorption. The performance of the proposed structure was evaluated by measuring its absorption at three terahertz frequency bands: 3.9 THz, 8.52 THz, and 11.83 THz, achieving absorption values of 99.65 %, 99.25 %, and 99.78 %, respectively. These high absorption rates make the sensor an excellent candidate for biosensing applications, particularly for detecting PSA in clinical samples. By testing the sensor with analytes containing PSA at 100, 200, 300, and 400 PM concentrations, the refractive index values were 1.3477, 1.3654, 1.3831, and 1.4008, respectively. When the analyte layer is placed on the three-band absorber structure, the peak shift is absorbed, enabling the detection of the desired analyte. The proposed structure demonstrated remarkable sensitivity, achieving 2638.4 GHz/RIU at a refractive index of 1.3831 and a frequency of 11.451 THz. This high sensitivity is particularly advantageous for detecting low concentrations of analytes. Such a sensor has great potential for enhancing the detection of biomarkers. These findings highlight the sensor's potential for high-sensitivity PSA detection, offering a valuable tool for early prostate cancer diagnosis and screening. © 2025 Elsevier GmbH
引用
收藏
相关论文
共 43 条
[1]  
Ilie G., Et al., A comprehensive 6-mo prostate cancer patient empowerment program decreases psychological distress among men undergoing curative prostate cancer treatment: a randomized clinical trial, Eur. Urol., 83, 6, pp. 561-570, (2023)
[2]  
Balk S.P., Ko Y.-J., Bubley G.J., Biology of prostate-specific antigen, J. Clin. Oncol., 21, 2, pp. 383-391, (2003)
[3]  
Siegel R.L., Miller K.D., Jemal A., Cancer statistics, 2019, CA A Cancer J. Clin., 69, 1, pp. 7-34, (2019)
[4]  
Khodaie A., Heidarzadeh H., Split ring resonator-based multimode plasmonic optical biosensors for comprehensive antigen detection, Sens Imaging, 25, 1, (2024)
[5]  
Angelis G.D., Rittenhouse H.G., Mikolajczyk S.D., Shamel L.B., Semjonow A., Twenty years of PSA: from prostate antigen to tumor marker, Rev. Urol., 9, 3, (2007)
[6]  
Abu-Bakr El-Bayoumy A.S., Hessien Keshta A.T., Sallam K.M., Ebeid N.H., Elsheikh H.M., Bayoumy B.E.-S., Extraction, purification of prostate-specific antigen (PSA), and establishment of radioimmunoassay system as a diagnostic tool for prostate disorders, J. Immunoass. Immunochem., 39, 1, pp. 12-29, (2018)
[7]  
McJimpsey E.L., Molecular form differences between prostate-specific antigen (PSA) standards create quantitative discordances in PSA elisa measurements, Sci. Rep., 6, 1, (2016)
[8]  
Sarkar P., Ghosh D., Bhattacharyay D., Setford S.J., Turner A.P.F., Electrochemical immunoassay for free prostate specific antigen (f-PSA) using magnetic beads, Electroanalysis, 20, 13, pp. 1414-1420, (2008)
[9]  
Du Y., Et al., Recyclable label-free SERS-based immunoassay of PSA in human serum mediated by enhanced photocatalysis arising from Ag nanoparticles and external magnetic field, Appl. Surf. Sci., 528, (2020)
[10]  
Jiang Z., Et al., The simultaneous detection of free and total prostate antigen in serum samples with high sensitivity and specificity by using the dual-channel surface plasmon resonance, Biosens. Bioelectron., 62, pp. 268-273, (2014)