Deep learning-based cone-beam CT motion compensation with single-view temporal resolution

被引:0
作者
Maier, Joscha [1 ]
Sawall, Stefan [1 ,2 ]
Arheit, Marcel [3 ]
Paysan, Pascal [3 ]
Kachelriess, Marc [1 ,2 ]
机构
[1] German Canc Res Ctr, Div X Ray Imaging & Comp Tomog, Heidelberg, Germany
[2] Heidelberg Univ, Med Fac Heidelberg, Heidelberg, Germany
[3] Varian Med Syst Imaging Lab GmbH, Baden Daettwil, Switzerland
关键词
4D CBCT; deep learning; motion compensation; IMAGE-RECONSTRUCTION; MICRO-CT; REGISTRATION; RADIOTHERAPY;
D O I
10.1002/mp.17911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundCone-beam CT (CBCT) scans that are affected by motion often require motion compensation to reduce artifacts or to reconstruct 4D (3D+time) representations of the patient. To do so, most existing strategies rely on some sort of gating strategy that sorts the acquired projections into motion bins. Subsequently, these bins can be reconstructed individually before further post-processing may be applied to improve image quality. While this concept is useful for periodic motion patterns, it fails in case of non-periodic motion as observed, for example, in irregularly breathing patients.PurposeTo address this issue and to increase temporal resolution, we propose the deep single angle-based motion compensation (SAMoCo).MethodsTo avoid gating, and therefore its downsides, the deep SAMoCo trains a U-net-like network to predict displacement vector fields (DVFs) representing the motion that occurred between any two given time points of the scan. To do so, 4D clinical CT scans are used to simulate 4D CBCT scans as well as the corresponding ground truth DVFs that map between the different motion states of the scan. The network is then trained to predict these DVFs as a function of the respective projection views and an initial 3D reconstruction. Once the network is trained, an arbitrary motion state corresponding to a certain projection view of the scan can be recovered by estimating DVFs from any other state or view and by considering them during reconstruction.ResultsApplied to 4D CBCT simulations of breathing patients, the deep SAMoCo provides high-quality reconstructions for periodic and non-periodic motion. Here, the deviations with respect to the ground truth are less than 27 HU on average, while respiratory motion, or the diaphragm position, can be resolved with an accuracy of about 0.75 mm. Similar results were obtained for real measurements where a high correlation with external motion monitoring signals could be observed, even in patients with highly irregular respiration.ConclusionsThe ability to estimate DVFs as a function of two arbitrary projection views and an initial 3D reconstruction makes deep SAMoCo applicable to arbitrary motion patterns with single-view temporal resolution. Therefore, the deep SAMoCo is particularly useful for cases with unsteady breathing, compensation of residual motion during a breath-hold scan, or scans with fast gantry rotation times in which the data acquisition only covers a very limited number of breathing cycles. Furthermore, not requiring gating signals may simplify the clinical workflow and reduces the time needed for patient preparation.
引用
收藏
页数:16
相关论文
共 46 条
[1]   VoxelMorph: A Learning Framework for Deformable Medical Image Registration [J].
Balakrishnan, Guha ;
Zhao, Amy ;
Sabuncu, Mert R. ;
Guttag, John ;
Dalca, Adrian, V .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (08) :1788-1800
[2]   Motion compensation for cone-beam CT using Fourier consistency conditions [J].
Berger, M. ;
Xia, Y. ;
Aichinger, W. ;
Mentl, K. ;
Unberath, M. ;
Aichert, A. ;
Riess, C. ;
Hornegger, J. ;
Fahrig, R. ;
Maier, A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17) :7181-7215
[3]   Marker-free motion correction in weight-bearing cone-beam CT of the knee joint [J].
Berger, M. ;
Mueller, K. ;
Aichert, A. ;
Unberath, M. ;
Thies, J. ;
Choi, J. -H. ;
Fahrig, R. ;
Maier, A. .
MEDICAL PHYSICS, 2016, 43 (03) :1235-1248
[4]   Artifact-resistant motion estimation with a patient-specific artifact model for motion-compensated cone-beam CT [J].
Brehm, Marcus ;
Paysan, Pascal ;
Oelhafen, Markus ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2013, 40 (10)
[5]   Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy [J].
Brehm, Marcus ;
Paysan, Pascal ;
Oelhafen, Markus ;
Kunz, Patrik ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2012, 39 (12) :7603-7618
[6]   Deformable motion compensation for interventional cone-beam CT [J].
Capostagno, S. ;
Sisniega, A. ;
Stayman, J. W. ;
Ehtiati, T. ;
Weiss, C. R. ;
Siewerdsen, J. H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05)
[7]   Dedicated Cone-Beam CT System for Extremity Imaging [J].
Carrino, John A. ;
Al Muhit, Abdullah ;
Zbijewski, Wojciech ;
Thawait, Gaurav K. ;
Stayman, J. Webster ;
Packard, Nathan ;
Senn, Robert ;
Yang, Dong ;
Foos, David H. ;
Yorkston, John ;
Siewerdsen, Jeffrey H. .
RADIOLOGY, 2014, 270 (03) :816-824
[8]   Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm [J].
Chen, Guang-Hong ;
Theriault-Lauzier, Pascal ;
Tang, Jie ;
Nett, Brian ;
Leng, Shuai ;
Zambelli, Joseph ;
Qi, Zhihua ;
Bevins, Nicholas ;
Raval, Amish ;
Reeder, Scott ;
Rowley, Howard .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (04) :907-923
[9]   Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment [J].
Choi, Jang-Hwan ;
Maier, Andreas ;
Keil, Andreas ;
Pal, Saikat ;
McWalter, Emily J. ;
Beaupre, Gary S. ;
Gold, Garry E. ;
Fahrig, Rebecca .
MEDICAL PHYSICS, 2014, 41 (06)
[10]   Evaluating reconstruction algorithms for respiratory motion guided acquisition [J].
Dillon, Owen ;
Keall, Paul J. ;
Shieh, Chun-Chien ;
O'Brien, Ricky T. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17)