Pollution Flashover Characteristics of Hydrophilic Surface Under Superimposed AC/DC Voltage

被引:1
作者
Chen, Sirui [1 ]
Luo, Yang [2 ]
Tu, Yanxin [1 ]
Wen, Lu [1 ]
Dong, Hongchuan [3 ]
Wang, Liming [1 ]
Cao, Bin [1 ]
机构
[1] Tsinghua Univ, Tsinghua Shenzhen Int Grad Sch, Engn Lab Power Equipment Reliabil Complicated Coas, Shenzhen 518055, Peoples R China
[2] Shenzhen Power Supply Co Ltd, China Southern Power Grid, Shenzhen 518000, Peoples R China
[3] State Grid Econ & Technol Res Inst Co Ltd, Res Inst Econ & Technol, Beijing 102209, Peoples R China
基金
中国国家自然科学基金;
关键词
Flashover; Pollution; Voltage; Surface contamination; Power supplies; High-voltage techniques; Discharges (electric); Surface treatment; Leakage currents; HVDC transmission; Arc development; artificial pollution test; pollution flashover; superimposed voltage; ARC;
D O I
10.1109/TDEI.2024.3521881
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Insulation devices in the flexible high-voltage direct current (HVdc) transmission system couple a specific ac component. To reveal the pollution flashover characteristics of hydrophilic surfaces under superimposed ac/dc voltage, this article designs a power supply system capable of generating superimposed voltage and conducts artificial pollution flashover tests on glass specimens. Under superimposed voltage, the arc development speed before flashover is faster, and the arc extinguishing and reignition phenomena occur even without a zero-crossing point. The ac component of the pollution flashover voltage decreases with the dc component superimposition, and this impact diminishes as pollution increases. When described as a peak value, the difference in flashover voltage under the same pollution degree is within 6.7% for different voltage configurations, while in terms of root-mean-square (rms) value, the difference ranges from 13.8% to 19.8%. The difference in flashover voltage under superimposed ac/dc voltage is also related to power supply characteristics, especially for heavily polluted surfaces. These results provide references for external insulation configuration in flexible HVdc projects.
引用
收藏
页码:1777 / 1784
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 2013, Standard IEC 60507
[2]  
[Anonymous], 2008, Standard GB/T 22707-2008
[3]  
Bessedik SA, 2011, C ELECT INSUL DIEL P, P550, DOI 10.1109/CEIDP.2011.6232716
[4]  
Bi J., 2023, P IEEE 4 INT C EL MA, P1, DOI [10.1109/ICEMPE57831.2023.10139739, DOI 10.1109/ICEMPE57831.2023.10139739]
[5]   Flashover characteristics of a hydrophobic surface covered by water [J].
Cao, Bin ;
Shao, Shichao ;
Wu, Xiaohan ;
Yin, Fanghui ;
Wang, Liming ;
Farzaneh, Masoud .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2021, 54 (07)
[6]   Influence of Partial Electric Arc on the Contamination Degree Monitoring System in View of Leakage Current [J].
Cao, Bin ;
Wang, Liming ;
Li, Xu ;
Guan, Zhicheng .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (04) :1545-1552
[7]  
Chi MH, 2013, C ELECT INSUL DIEL P, P817, DOI 10.1109/CEIDP.2013.6747458
[8]   An Experimental Study of AC Arc Propagation over a Contaminated Surface [J].
Li, Jian ;
Guan, Zhicheng ;
Wang, Liming ;
Yang, Hailong ;
Zhou, Jun .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (04) :1360-1368
[9]  
Li Jian, 2010, C ELECT INSULATION D
[10]  
Liu Q. L., 2013, P 2 IET REN POW GEN, P1, DOI [10.1049/cp.2013.1780, DOI 10.1049/CP.2013.1780]