Reliability and Accuracy of Linear Position Transducers During the Bench Press and Back Squat: Implications for Velocity-Based Training

被引:0
作者
Montoro-Bombu, Raynier [1 ,2 ,3 ]
Costa, Armando [3 ]
Sousa, Paulo Malico [3 ,4 ]
Pinheiro, Valter [3 ,4 ]
Forte, Pedro [5 ,6 ,7 ]
Monteiro, Luis [8 ,9 ,10 ]
Ribeiro, Alex S. [1 ,2 ]
Rama, Luis [1 ,2 ]
机构
[1] Univ Coimbra, Fac Sport Sci & Phys Educ, P-3040256 Coimbra, Portugal
[2] Univ Lisbon, Fac Human Kinet, Ctr Interdisciplinar Performance Humana CIPER, P-1499002 Cruz Quebrada, Portugal
[3] Univ Lisbon & Tagus Valley, ISCE Polytech, Sports Sci Lab LAB ISCE, Dept Sport Sci, P-2620379 Lisbon, Portugal
[4] Live Quat Res Ctr LQRC, Complexo Andaluz,Apartado 279, P-2001904 Santarem, Portugal
[5] Higher Inst Educ Sci Douro, Dept Sports, P-4560708 Penafiel, Portugal
[6] Inst Politecn Braganca, Dept Sports Sci, P-5300253 Braganca, Portugal
[7] Inst Politecn Braganca, Res Ctr Act Living & Wellbeing Livewell, P-5300253 Braganca, Portugal
[8] Lusofona Univ, Ctr Invest Desporto Educ Fis & Exercicio & Saude C, P-1749024 Lisbon, Portugal
[9] Castilla La Mancha Univ, Fac Sport Sci, Toledo 45071, Spain
[10] Higher Inst Police Sci & Internal Secur, ICPOL, P-1300663 Lisbon, Portugal
关键词
biomechanics; velocity-based training; force; monitoring training and testing; strength; performance; VALIDITY; PHASE; LOAD;
D O I
10.3390/jfmk10020109
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: Selecting the right linear position transducer (LPT) for velocity-based training monitoring sometimes presents uncertainties for coaches. Objectives: This study rigorously examined the test-retest reliability of three LPT-Cs using a simultaneous triangulation method of the same device during bench press (BP) and back squat (SQ) exercises performed on a Smith machine. Methods: Forty university students-13 females (23 +/- 2 years) and 27 males (31.5 +/- 6 years)-voluntarily participated in a randomized repeated-measures study. LPTs were randomly assigned numbers and placed at 5 cm apart to measure and collect bar displacement (triangle S), mean propulsive velocity (MPV), peak velocity (PV), and time to peak velocity (T-PV). Each volunteer performed three BP and SQ attempts with pre-standardized loads (males: BP >= 40 kg and SQ >= 60 kg; females: BP >= 25 kg and SQ >= 40 kg). Results: The main findings of this study support a high degree of reliability for LPTs. For all variables, the absolute reliability presented significant values (p <= 0.05), with an intraclass correlation coefficient >= 0.995, a 95% confidence interval between 0.992-0.999, a coefficient of variation <= 10%, and a standard error of the mean <= 0.031. Conclusions: Scientists and coaches can use the LPT device as a reliable tool for monitoring velocity-based training by providing rigorous measurements of triangle S, MPV, PV, and T-PV during BP and SQ exercises. In addition, the smallest real difference reported may be useful in identifying minimal changes in triangle S within a single set (BP = 0.10 cm; SQ = 0.13 cm).
引用
收藏
页数:14
相关论文
共 40 条
[1]   Analysis of Wearable and Smartphone-Based Technologies for the Measurement of Barbell Velocity in Different Resistance Training Exercises [J].
Balsalobre-Fernandez, Carlos ;
Marchante, David ;
Baz-Valle, Eneko ;
Alonso-Molero, Ivan ;
Jimenez, Sergio L. ;
Munoz-Lopez, Mario .
FRONTIERS IN PHYSIOLOGY, 2017, 8
[2]   RELIABILITY AND VALIDITY OF THE LOAD-VELOCITY RELATIONSHIP TO PREDICT THE 1RM BACK SQUAT [J].
Banyard, Harry G. ;
Nosaka, Kazunori ;
Haff, G. Gregory .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (07) :1897-1904
[3]   Smallest real difference, a link between reproducibility and responsiveness [J].
Beckerman, H ;
Roebroeck, ME ;
Lankhorst, GJ ;
Becher, JG ;
Bezemer, PD ;
Verbeek, ALM .
QUALITY OF LIFE RESEARCH, 2001, 10 (07) :571-578
[4]   Are physical activity levels, cardiorespiratory fitness and peak power associated with Parkinson's disease severity? [J].
Bonde-Jensen, Frederik ;
Dalgas, Ulrik ;
Langeskov-Christensen, Martin .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2024, 460
[5]   Reproducibility and Repeatability of Five Different Technologies for Bar Velocity Measurement in Resistance Training [J].
Courel-Ibanez, Javier ;
Martinez-Cava, Alejandro ;
Moran-Navarro, Ricardo ;
Escribano-Penas, Pablo ;
Chavarren-Cabrero, Javier ;
Gonzalez-Badillo, Juan Jost ;
Pallares, Jesus G. .
ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (07) :1523-1538
[6]  
DIETZ V, 1978, PFLUG ARCH EUR J PHY, pR71
[7]   Reliability, measurement error and minimum detectable change in mobility measures: a cohort study of community-dwelling adults aged 50 years and over in Ireland [J].
Donoghue, Orna A. ;
Savva, George M. ;
Boersch-Supan, Axel ;
Kenny, Rose Anne .
BMJ OPEN, 2019, 9 (11)
[8]   Validity and reliability of a linear positional transducer across commonly practised resistance training exercises [J].
Dorrell, Harry F. ;
Moore, Joseph M. ;
Smith, Mark F. ;
Gee, Thomas I. .
JOURNAL OF SPORTS SCIENCES, 2019, 37 (01) :67-73
[9]   Measures of reliability in sports medicine and science [J].
Hopkins, WG .
SPORTS MEDICINE, 2000, 30 (01) :1-15
[10]   Test-Retest and Minimal Detectable Change in the Assessment of Muscle Strength and Muscle Power in Upper and Lower Extremity Exercises in 9-to 14-Year-Old Children [J].
Horta-Gim, Mario A. ;
Romero-Perez, Ena Monserrat ;
Medina-Perez, Carlos ;
Tanori-Tapia, Jose Manuel ;
Nunez-Othon, Gabriel ;
Novo, Andre ;
de Paz, Jose Antonio .
APPLIED SCIENCES-BASEL, 2021, 11 (05) :1-14