Large Scale, data driven, Digital Twin Models: Outlier Detection and Imputation

被引:0
作者
Wieser, Raymond [1 ]
Fan, Yangxin [1 ]
Yu, Xuanji [1 ]
Braid, Jennifer [2 ]
Shaton, Avishai [3 ]
Hoffma, Adam [4 ]
Ben Spurgeon [5 ]
Gibbons, Daniel [6 ]
Bruckman, Laura S. [1 ]
Wu, Yinghui [1 ]
French, Roger H. [1 ]
机构
[1] Case Western Reserve Univ, SDLE Res Ctr, Cleveland, OH 44106 USA
[2] Sandia Natl Labs, Albuquerque, NM USA
[3] SolarEdge, Herzliyya, Israel
[4] Maxeon Solar Technol, Singapore, Singapore
[5] Brookfield Renewable, Toronto, ON, Canada
[6] Bay4 Energy, Tucson, AZ USA
来源
2024 IEEE 52ND PHOTOVOLTAIC SPECIALIST CONFERENCE, PVSC | 2024年
关键词
data-driven Digital Twin; Outlier Detection; Maintenance; Graph Neural Network; Imputation; Timeseries Analysis; Timeseries; Statistical Analysis; Deep Learning;
D O I
10.1109/PVSC57443.2024.10748985
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Precise and comprehensive records of system performance is imperative for the efficient monitoring and prediction of Photovoltaic (PV) power generation. Nonetheless, the inevitable failure of real-world sensors and monitoring devices results in information loss. Additionally, the high variability in production data can obfuscate erroneous measurements as nominal values. The occurrence of such "missingness" significantly impacts the stability and precision of performance estimation. By leveraging the inherent value dependencies present in PV production data, graph data driven Digital Twin models can be created for individual sites that capture the high frequency spatial weather patterns that determine the precise performance for that specific instance in time. Through varying the graph structure, the same model architecture can target both outlier detection, and imputation of missing values. st-GAE, an existing spatio-temporal graph autoencoder, was used to detect and impute outliers for a collection of 98 inverters with 5 minute interval data for a period of two years. Outlier detection was compared against existing maintenance logs which were available for all of the systems. stGAE was shown to correctly identify 90% of maintenance events and was able to reconstruct those missing values with a MAE of less than 1.5W.
引用
收藏
页码:0902 / 0905
页数:4
相关论文
共 18 条
[1]  
Cini A, 2022, Arxiv, DOI arXiv:2108.00298
[2]  
Diao ZL, 2019, AAAI CONF ARTIF INTE, P890
[3]   Assessing the outdoor operating temperature of photovoltaic modules [J].
Faiman, David .
PROGRESS IN PHOTOVOLTAICS, 2008, 16 (04) :307-315
[4]  
Fan Yangxin, 2023, P 2023 ACM SIGMOD IN
[5]  
Karimi AM, 2021, AAAI CONF ARTIF INTE, V35, P15323
[6]  
King D. L., 2004, Tech. Rep. SAND2004-3535
[7]  
King DL, 2004, Photovoltaic array performance model
[8]   Best practices for photovoltaic performance loss rate calculations [J].
Lindig, Sascha ;
Theristis, Marios ;
Moser, David .
PROGRESS IN ENERGY, 2022, 4 (02)
[9]   Outdoor PV System Monitoring-Input Data Quality, Data Imputation and Filtering Approaches [J].
Lindig, Sascha ;
Louwen, Atse ;
Moser, David ;
Topic, Marko .
ENERGIES, 2020, 13 (19)
[10]  
Livera A., 2020, Progress in Photovoltaics: Research and Applications, P3349