Ultrasonography can be more informative than computed tomography for diagnosing radial head fractures: An illustrative case series

被引:1
作者
Scholl, Eckehart [1 ,2 ]
Jakob, Marcel [3 ]
Vach, Werner [3 ]
机构
[1] Merian Iselin Klin Orthopadie Chirurg, ORTHO NOTFALL, Basel, Switzerland
[2] Merian Iselin Forsch AG, Forsch, Basel, Switzerland
[3] Basel Acad Qual & Res Med, Res Dept, Basel, Switzerland
来源
ULTRASCHALL IN DER MEDIZIN | 2024年
关键词
ultrasound; Computed tomography; Radial head fracture; OF-CARE ULTRASOUND; ELBOW;
D O I
10.1055/a-2445-3611
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose Ultrasonography is increasingly being discussed as an alternative to X-rays in emergency department settings. Systematic comparisons of the 2 modalities are often based on the use of computed tomography as a reference. When diagnosing patients with elbow trauma, the physicians at our emergency department experienced that ultrasonography can be more informative than cone beam computed tomography for identifying radial head fractures. Our goal is to share this experience with the scientific community. Materials and Methods All patients diagnosed with a radial head fracture in our emergency department between January 2021 and November 2022 were identified. The images of 18 cases in which both point-of-care ultrasonography and cone beam computed tomography had been used were reviewed by us. Eight examples were selected illustrating the variation in coincidence or discrepancy between ultrasonography and computed tomography. Results The 8 examples illustrate that ultrasonography can be more informative than cone beam computed tomography or vice versa. Conclusion The joint application of ultrasonography and computed tomography is advisable if a correct diagnosis of the extent and components of radial head fractures is of uttermost importance.
引用
收藏
页数:10
相关论文
共 17 条
[11]   Diagnostic Performance of Ultrasonography for Detection of Pediatric Elbow Fracture: A Meta-analysis [J].
Lee, Sun Hwa ;
Yun, Seong Jong .
ANNALS OF EMERGENCY MEDICINE, 2019, 74 (04) :493-502
[12]  
Malahias MA, 2018, ARCH BONE JT SURG-AB, V6, P539
[13]   Diagnosis of occult radial head and neck fracture in adults [J].
Pavic, Roman ;
Margetic, Petra ;
Hnatesen, Dijana .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 :S119-S124
[14]   Diagnostic accuracy of point-of-care ultrasound in detecting upper and lower extremity fractures: An evidence-based approach [J].
Pourmand, A. ;
Shokoohi, H. ;
Maracheril, R. .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (01) :134-136
[15]   Diagnostic accuracy of ultrasound for upper extremity fractures in children: A systematic review and meta-analysis* [J].
Tsou, Po-Yang ;
Ma, Yu-Kun ;
Wang, Yu-Hsun ;
Gillon, Jason T. ;
Rafael, John ;
Deanehan, Julia K. .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 44 :383-394
[16]   Artificial Intelligence (AI) for Fracture Diagnosis: An Overview of Current Products and Considerations for Clinical Adoption, From the AJR Special Series on AI Applications [J].
Zech, John R. ;
Santomartino, Samantha M. ;
Yi, Paul H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (06) :869-878
[17]   Diagnostic Accuracy of 3D Ultrasound and Artificial Intelligence for Detection of Pediatric Wrist Injuries [J].
Zhang, Jack ;
Boora, Naveenjyote ;
Melendez, Sarah ;
Rakkunedeth Hareendranathan, Abhilash ;
Jaremko, Jacob .
CHILDREN-BASEL, 2021, 8 (06)