Numerical Study on Conjugate Heat and Mass Transfer Characteristics Around Thermosolutal Exchangers: Effect of Flow Parameters and Solid Block Arrangement

被引:0
作者
Shivli, Ameeya Kumar [1 ]
Nayak, Ameeya Kumar [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Math, Roorkee 247667, India
关键词
mixed convection; slot-ventilated enclosure; thermo-contaminated block; Sherwood number; Nusselt number; cooling efficiency; average temperature; Bejan number; performance evaluation criterion; boundary layer; AIRBORNE POLLUTANT REMOVALS; DIFFUSIVE MIXED CONVECTION; SOLAR CHIMNEY; VENTILATED CAVITY; ENTROPY GENERATION; AIR-FLOW; PERFORMANCE; ENCLOSURE; SIMULATION; TRANSPORT;
D O I
10.1115/1.4068023
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effect of airflow characteristics within a slot-ventilated enclosure is carried out numerically to optimize the heat and contaminants' removal rate where cold air is injected via an inlet port. The contaminated air is expelled by the chimney outlet port positioned along the left side of the top wall. Based on the structure dynamics, the flow governing equation is dealt with the Navier-Stokes equations coupled with the energy equation, where the maximum cooling efficiency is evaluated. A finite volume-based semi-implicit method for pressure-linked equations (SIMPLEs) method is utilized to deal with the nonlinear coupled partial differential equations to evaluate the flow variation with changing various physical parameters. Different thermosolutal block orientations are considered to investigate the effective interpretation of heat and mass transfer in a natural chamber. The effects of the inclination angle of the chimney, Richardson and Reynolds numbers on the average heat and mass transfer rate, average temperature, average Bejan number, and performance evaluation criterion (PEC) inside the system are evaluated. Boundary layer analysis is performed to examine the transient behavior of the boundary layer flow dominated by natural convection near the wall heater on the enclosure's left wall and results are found to agree with our numerical results.
引用
收藏
页数:26
相关论文
共 62 条
[1]   Experimental and numerical analysis of the influence of inlet configuration on the performance of a roof top solar chimney [J].
Al-Kayiem, Hussain H. ;
Sreejaya, K. V. ;
Chikere, Aja O. .
ENERGY AND BUILDINGS, 2018, 159 :89-98
[2]   On the natural convection heat transfer in a rectangular passage solar air heater [J].
Al-Kayiem, Hussain H. ;
Yassen, Tadahmun A. .
SOLAR ENERGY, 2015, 112 :310-318
[3]   Mixed convection heat transfer from two aligned horizontal heated cylinders in a vented square enclosure [J].
Ali, Omar Mohammed ;
Alomar, Omar Rafae .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 25
[4]   Mixed convection heat transfer and entropy generation of water inside a square vented enclosure with and without four vibrating cylinders in horizontal and vertical directions [J].
Almensoury, Mushtaq F. ;
Al-Srayyih, Basil Mahdi ;
Al-Amir, Qusay Rasheed ;
Hamzah, Hameed K. ;
Abed, Azher M. ;
Ali, Farooq H. ;
Bayraktar, Seyfettin ;
Arici, Muesluem ;
Hatami, Mohammad .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2024, 85 (13) :2069-2095
[5]   Effect of solar chimney inclination angle on space flow pattern and ventilation rate [J].
Bassiouny, Ramadan ;
Korah, Nader S. A. .
ENERGY AND BUILDINGS, 2009, 41 (02) :190-196
[6]  
Bejan A., 1985, International Journal of Heat and Fluid Flow, V6, P149, DOI 10.1016/0142-727X(85)90002-5
[7]  
BEJAN A., 2013, Wiley Chaper, V4th, DOI DOI 10.1002/9781118671627
[8]  
Bejan A., 2013, ENTROPY GENERATION M, DOI [10.1201/9781482239171, DOI 10.1201/9781482239171]
[9]   Oscillatory double-diffusive mixed convection in a two-dimensional ventilated enclosure [J].
Ben Beya, Brahim ;
Lili, Taieb .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (23-24) :4540-4553
[10]   MIXED CONVECTION IN A VERTICAL CHANNEL WITH DISCRETE HEAT SOURCES USING A POROUS MATRIX [J].
Bensouici, Moumtez ;
Bessaih, Rachid .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2010, 58 (07) :581-604