摘要
PurposeThis study aims to evaluate the accuracy of fit of full-arch implant titanium frameworks fabricated from a fully digital workflow using a novel micro-CT measurement technique.Materials and MethodsA 3D-printed model with four implant analogs was fabricated. A baseline micro-CT was obtained after placing temporary cylinders on the model. Next, the printed model was scanned with an intraoral scanner (TRIOS 5), and the STL files were used to fabricate 10 titanium frameworks. Each framework was placed back on the model, and another micro-CT was taken under two conditions: single screw test (SST-CT) and final fit test (FFT-CT), and the measurements were compared to the baseline. Framework passivity was evaluated using a single-screw test (SST) and a screw-resistance test (SRT). The accuracy of the intraoral scans was assessed by superimposing the 10 scans with a laboratory scan STL to determine if the misfit was due to scanning or milling and designing errors.ResultsNone of the frameworks was deemed acceptable using SST-CT, and only three had an acceptable fit using FFT-CT. SST and SRT non-passivity rates were 60% and 80%, respectively. Superimposition analysis revealed that only two intraoral scans used for framework fabrication fell within the acceptable deviation range of 150 microns, suggesting a high tendency for scanning errors and a possible milling or designing error in two samples.ConclusionThe results show a significant level of misfit. This suggests that the full-digital workflow for full-mouth rehabilitation can present some limitations. Due to the rapid advancement in intraoral scanning, further studies are required to validate these findings.
引用
收藏
页数:11
相关论文
共 72 条
[1]   Magnitude of misfit threshold in implant-supported restorations: A systematic review [J].
Abdelrehim, Aly ;
Etajuri, Enas Abdalla ;
Sulaiman, Eshamsul ;
Sofian, Hazrina ;
Salleh, Nosizana Mohd .
JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03) :528-535
[2]   Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors [J].
Abduo, Jaafar ;
Elseyoufi, Mohamed .
EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2018, 26 (03) :101-121
[3]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[4]   Accuracy of the Different Materials Used to Fabricate a Verification Jig of Implant-Supported Fixed Complete Dental Prostheses: An In Vitro Study [J].
Aljohani, Mawaddah S. ;
Bukhari, Heba A. ;
Alshehri, Mayar ;
Alamoudi, Ahmed .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
[5]   Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study [J].
Andriessen, Frank S. ;
Riikens, David R. ;
van der Meer, Wither J. ;
Wismeijer, Daniell W. .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) :186-194
[6]  
[Anonymous], Parallax
[7]   Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application: 3-D finite element analysis [J].
Bacchi, Atais ;
Xediek Consani, Rafael Leonardo ;
Mesquita, Marcelo Ferraz ;
Fernandes dos Santos, Mateus Bertolini .
ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) :1243-1249
[8]   Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis [J].
Basaki, Kinga ;
Alkumru, Hasan ;
De Souza, Grace ;
Finer, Yoav .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) :792-799
[9]   Trueness and precision of 5 intraoral scanners for scanning edentulous and dentate complete-arch mandibular casts: A comparative in vitro study [J].
Braian, Michael ;
Wennerberg, Ann .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (02) :129-136
[10]  
Buzayan Muaiyed Mahmoud, 2014, J Indian Prosthodont Soc, V14, P16, DOI 10.1007/s13191-013-0343-x