Objective Versus Subjective Depth of Focus Correlation in Pseudophakic Eyes

被引:0
作者
Nanavaty, Mayank A. [1 ,2 ]
Safir, Margarita [3 ]
Alwindi, Muhanned [4 ]
机构
[1] Brighton & Sussex Univ Hosp NHS Trust, Sussex Eye Hosp, Eastern Rd, Brighton BN2 5BF, England
[2] Univ Sussex, Brighton & Sussex Med Sch, Brighton, England
[3] Rabin Med Ctr, Ophthalmol Dept, Petah Tiqwa, Israel
[4] Tracey Technol, Houston, TX USA
关键词
INTERMEDIATE VISION; INTRAOCULAR LENSES; OPTICAL-QUALITY; EXTENDED DEPTH; OF-FOCUS; ABERRATIONS; IOL;
D O I
10.3928/1081597X-20250207-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To develop a method for quantifying objective depth of focus (DOF) from the visual Strehl ratio based on the optical transfer function (VSOTF), measured on a ray-tracing aberrometer (iTrace; Tracey Technologies) and to compare it to the subjective clinical DOF in two groups of pseudophakic eyes with varying asphericity of the intraocular lenses (IOLs). METHODS: In this cross-sectional study, two groups with negatively aspheric (Eyhance; Johnson & Johnson) and aspherically neutral (RayOne; Rayner) IOLs were assessed 3 to 9 months postoperatively. The patient assessments included: logarithm of the minimum angle of resolution visual acuity, refraction, defocus curves, and iTrace assessments. The primary outcome was to determine the threshold of VSOTF (%) corresponding to subjective DOF. Secondary outcomes were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, keratometry, and wavefront aberrometry. The specific threshold of VSOTF matching the subjective DOF was determined. RESULTS: Forty-two eyes (21 patients in each IOL group) were analyzed. For the primary outcome, in the Eyhance versus the RayOne IOL group and all eyes together there was no significant difference between 25% (P = .10 vs .28; P = .07) and 30% (P = .55 vs .73; P = .58) VSOTF and subjective DOF, respectively. For secondary outcomes, UDVA was better in the Eyhance group (P = .02). There was no difference in CDVA, manifest refraction, and keratometry. There was a significant difference in total and internal spherical aberration between the two groups, although it was not clinically significant. CONCLUSIONS: This study showed that a 25% to 30% threshold of VSOTF values on iTrace measurements (Nanavaty Threshold) gives an objective DOF estimate, equivalent to clinical DOF derived from the defocus curve irrespective of the IOL's optical profiles.
引用
收藏
页码:e310 / e317
页数:8
相关论文
共 28 条
[1]   Enhancing the Intermediate Vision of Monofocal Intraocular Lenses Using a Higher Order Aspheric Optic [J].
Alarcon, Aixa ;
Canovas, Carmen ;
Koopman, Bram ;
Weeber, Henk ;
Auffarth, Gerd U. ;
Piers, Patricia A. .
JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (08) :520-+
[2]   Visual Strehl Performance of IOL Designs with Extended Depth of Focus [J].
Arias Gallego, Augusto ;
Bara, Salvador ;
Jaroszewicz, Zbigniew ;
Kolodziejczyk, Andrzej .
OPTOMETRY AND VISION SCIENCE, 2012, 89 (12) :1702-1707
[3]   Noticeable, troublesome and objectionable limits of blur [J].
Atchison, DA ;
Fisher, SW ;
Pedersen, CA ;
Ridall, PG .
VISION RESEARCH, 2005, 45 (15) :1967-1974
[4]   Wavefront measurements of diffractive and refractive multifocal intraocular lenses in an artificial eye [J].
Campbell, Charles E. .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :308-311
[5]   Problems in the measurement of wavefront aberration for eyes implanted with diffractive bifocal and multifocal intralocular lenses [J].
Charman, W. Neil ;
Montes-Mico, Robert ;
Radhakrishnan, Hema .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :280-286
[6]   Biomechanical properties of cornea and ocular aberrations in myopic eyes [J].
Dhiman, Rebika ;
Singh, Divya ;
Vanathi, Murugesan ;
Tandon, Radhika ;
Mahalingam, Karthikeyan .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (04) :538-543
[7]   Intermediate addition multifocals provide safe stair ambulation with adequate 'short-term' reading [J].
Elliott, David B. ;
Hotchkiss, John ;
Scally, Andrew J. ;
Foster, Richard ;
Buckley, John G. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2016, 36 (01) :60-68
[8]   Optimizing measurement of subjective amplitude of accommodation with defocus curves [J].
Gupta, Navneet ;
Wolffsohn, James S. W. ;
Naroo, Shehzad A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (08) :1329-1338
[9]   Comparison of visual performance with iTrace analyzer following femtosecond laser-assisted cataract surgery with bilateral implantation of two different trifocal intraocular lenses [J].
Ju, Rui-Hong ;
Qu, Hao-Kun ;
Wu, Zhe-Ming ;
Chen, Yun ;
Wu, Li-Nan ;
Long, Yuan ;
Wang, Zheng .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2023, 16 (11) :1773-1781
[10]   Comparison of two swept-source optical coherence tomography devices, a Scheimpflug camera system and a ray-tracing aberrometer in the measurement of corneal power in patients with cataract [J].
Ma, Shan ;
Gao, Rongyu ;
Sun, Jing ;
Yang, Jun ;
Wen, Kai ;
Chen, Xiteng ;
Zhao, Fangyu ;
Xu, Xinyan ;
Tian, Fang .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (05) :1567-1578