Predicting blood pressure without a cuff using a unique multi-modal wearable device and machine learning algorithm

被引:1
作者
Hsiao, Chin-To [1 ]
Hong, Sungcheol [1 ,4 ]
Branan, Kimberly L. [1 ]
McMurray, Justin [1 ]
Coté, Gerard L. [1 ,2 ,3 ]
机构
[1] Department of Biomedical Engineering, Texas A&M University, College Station, 77843, TX
[2] Texas A&M Engineering Experiment Station, Center for Remote Health Technologies and Systems, College Station, 77843, TX
[3] Department of Electrical and Computer Engineering, Texas A&M University, College Station, 77843, TX
[4] Electrical and Electronic Convergence Department, Hongik University, Sejong
基金
美国国家科学基金会;
关键词
Bioimpedance; Cuffless blood pressure; Machine learning; PPG; Wearable devices;
D O I
10.1016/j.compbiomed.2025.110357
中图分类号
学科分类号
摘要
Blood pressure is a critical risk factor for cardiovascular diseases (CVDs), yet most adults do not monitor it frequently enough to prevent serious complications. This is in part because the traditional cuff-based method is inconvenient, uncomfortable, and does not allow for continuous monitoring. To address these constraints, we developed a unique multi-modal wearable device and used a random forest regression (RFR) algorithm that resulted in a model capable of accurate cuffless blood pressure prediction. This multi-modal device features two photoplethysmography (PPG) sensors and two bioimpedance (BioZ) sensors to measure pulse wave propagation along the radial artery on the wrist. The redundancy in the design enhances prediction accuracy. To validate the device, a novel human subject study protocol was also developed that allows an individual's blood pressure to rise safely and repeatably by more than 40 mmHg (systolic pressure) from baseline measurements. In this study, using multiple pulsatile waveforms from the PPG and BioZ sensors as inputs into the machine learning prediction algorithm, showed that the model had higher accuracy than models using a single sensor. Specifically, the training, validation, and leaving one subject out of data sets all showed mean absolute errors of less than 3.3 mmHg for both systolic and diastolic blood pressures (BPs). While results from this test were promising, a subject-wise evaluation showed variability depending on how well an individual's BP distribution matched the training set. These findings demonstrate the potential for a universal model for cuffless BP estimation, with further validation needed in more diverse populations. Thus, the accompaniment of the RFR model with the multi-modal wearable device offers the potential for robust and continuous blood pressure monitoring, providing a unique and practical solution for long-term cardiovascular health management. © 2025
引用
收藏
相关论文
共 68 条
[1]  
Di Cesare M., Perel P., Taylor S., Kabudula C., Bixby H., Gaziano T.A., McGhie D.V., Mwangi J., Pervan B., Narula J., Pineiro D., Pinto F.J., The heart of the world, Glob Heart, 19, (2024)
[2]  
Lindstrom M., DeCleene N., Dorsey H., Fuster V., Johnson C.O., LeGrand K.E., Mensah G.A., Razo C., Stark B., Varieur Turco J., Roth G.A., Global burden of cardiovascular diseases and risks collaboration, 1990-2021, J. Am. Coll. Cardiol., 80, pp. 2372-2425, (2022)
[3]  
Wu C.Y., Hu H.Y., Chou Y.J., Huang N., Chou Y.C., Li C.P., High blood pressure and all-cause and cardiovascular disease mortalities in community-dwelling older adults, Medicine (Baltim.), 94, (2015)
[4]  
Malik R., Georgakis M.K., Vujkovic M., Damrauer S.M., Elliott P., Karhunen V., Giontella A., Fava C., Hellwege J.N., Shuey M.M., Edwards T.L., Rogne T., Asvold B.O., Brumpton B.M., Burgess S., Dichgans M., Gill D., Relationship between blood pressure and incident cardiovascular disease: linear and nonlinear mendelian randomization analyses, Hypertension, 77, pp. 2004-2013, (2021)
[5]  
Gulec S., Early diagnosis saves lives: focus on patients with hypertension, Kidney Int. Suppl., 3, pp. 332-334, (2011)
[6]  
Schutte A.E., Kollias A., Stergiou G.S., Blood pressure and its variability: classic and novel measurement techniques, Nat. Rev. Cardiol., 19, pp. 643-654, (2022)
[7]  
Hu J.R., Park D.Y., Agarwal N., Herzig M., Ormseth G., Kaushik M., Giao D.M., Turkson-Ocran R.N., Juraschek S.P., The promise and illusion of continuous, cuffless blood pressure monitoring, Curr. Cardiol. Rep., 25, pp. 1139-1149, (2023)
[8]  
Tan I., Gnanenthiran S.R., Chan J., Kyriakoulis K.G., Schlaich M.P., Rodgers A., Stergiou G.S., Schutte A.E., Evaluation of the ability of a commercially available cuffless wearable device to track blood pressure changes, J. Hypertens., 41, pp. 1003-1010, (2023)
[9]  
Mukkamala R., Yavarimanesh M., Natarajan K., Hahn J.O., Kyriakoulis K.G., Avolio A.P., Stergiou G.S., Evaluation of the accuracy of cuffless blood pressure measurement devices: challenges and proposals, Hypertension, 78, pp. 1161-1167, (2021)
[10]  
Falter M., Scherrenberg M., Driesen K., Pieters Z., Kaihara T., Xu L., Caiani E.G., Castiglioni P., Faini A., Parati G., Dendale P., Smartwatch-based blood pressure measurement demonstrates insufficient accuracy, Front. Cardiovasc. Med., 9, (2022)