Research on a risk assessment model for dense urban cable channels based on fuzzy mathematics

被引:0
作者
Nie, Yongjie [1 ]
Chen, Daoyuan [1 ]
Zheng, Shuai [2 ]
Xu, Xiaowei [1 ]
Wang, Xilian [2 ]
Wu, Zhensheng [2 ]
机构
[1] Yunnan Power Grid Co Ltd, Elect Power Res Inst, Kunming, Peoples R China
[2] Beijing Jiaotong Univ, Sch Elect Engn, Beijing, Peoples R China
关键词
dense urban cable channels; risk assessment model; fuzzy mathematics; membership function; fuzzy comprehensive evaluation method; FAULT; DEFECTS;
D O I
10.3389/fbuil.2025.1565348
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With the acceleration of urbanization, the safe and stable operation of dense urban cable channels is of great importance to the guarantee of urban power and communication systems. Cable channels face many sources of risk that bring great challenges to urban power supplies. Most existing risk assessment methods are based on accurate mathematical models, which require clear and deterministic boundaries of assessment indicators. These methods have difficulty in dealing with the fuzziness and uncertainty of cable channel risk factors, such as the challenge of determining the degree of aging of cable insulation or the degree of influence of external environmental factors that cannot be simply quantified. This paper presents a risk assessment model of a dense urban cable passage based on fuzzy mathematics. The model combines a membership function with a fuzzy comprehensive evaluation method to analyze and classify the risk factors of a dense urban cable passage. Eight risk factors were identified, including external damage, facility defects, and non-standard cable laying, and the importance of each factor was evaluated by constructing a membership matrix based on historical data and expert scoring methods. A typical dense cable trench and cable tunnel in actual operation in a region of China Southern Power Grid are analyzed, and the risk level is calculated by MATLAB 2021a programming. The results show that the model can effectively assess the level of risk and clearly show the impact of individual risk factors on the overall risk. For example, in the cable trench risk assessment, the model accurately identifies that external damage and cable overheating risk factors lead to moderate risk, and the remaining six factors are low risk. In the cable tunnel assessment, the corresponding risk level of each risk factor is also accurately determined. This indicates that the evaluation method based on fuzzy mathematics can not only quantify the uncertainty of risk factors but also improve the rationality of the evaluation results and provide a scientific decision basis for the safety management and maintenance of cable channels. The model has significant advantages over traditional evaluation methods.
引用
收藏
页数:12
相关论文
共 27 条
[1]   Energy-based coupling risk assessment (CRA) model for urban underground utility tunnels [J].
Bai, Yiping ;
Wu, Jiansong ;
Liu, Kunqi ;
Sun, Yuxin ;
Shen, Siyao ;
Cao, Jiaojiao ;
Cai, Jitao .
RELIABILITY ENGINEERING & SYSTEM SAFETY, 2024, 250
[2]   BN-RA: A Hybrid Model for Risk Analysis of Overload-Induced Early Cable Fires [J].
Chen, Xiaolong ;
Huang, Guozhong ;
Gao, Xuehong ;
Ou, Shengnan ;
Li, Yatao ;
Hezam, Ibrahim M. .
APPLIED SCIENCES-BASEL, 2021, 11 (19)
[3]   An Analytical Approach to Locate Short Circuit Fault in a Cable Using Sweep Frequency Response Analysis [J].
Das, Aritra ;
Reddy, Chakradhar C. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (05) :5235-5244
[4]   Identification of appropriate risk analysis techniques for railway turnout systems [J].
Dindar, Serdar ;
Kaewunruen, Sakdirat ;
An, Min .
JOURNAL OF RISK RESEARCH, 2018, 21 (08) :974-995
[5]   Traveling-wave-based fault-location scheme for multiend-aged underground cable system [J].
Gilany, Mahmoud ;
Ibrahim, Doaa Khalil ;
Eldin, El Sayed Tag .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) :82-89
[6]   Research on Accident Prediction of Cable Tunnel Based on FT-GS-SVR Algorithm [J].
Ji, Chao ;
Wang, Liang ;
Hou, Wei ;
Huang, Xinbo ;
Gao, Mingjiang .
JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2025, 20 (01) :889-902
[7]   Research on fault location algorithm of TPSS based on PSOA [J].
Jia, Yunqian .
PEERJ COMPUTER SCIENCE, 2023, 9
[8]  
Khan Y, 2024, ENVIRON DEV SUSTAIN, V26, P14981, DOI 10.1007/s10668-023-03231-y
[9]   Investigation on the stability of HTS power cable under fault current considering stabilizer [J].
Kim, Seokho ;
Kim, Jae-Ho ;
Cho, Jeonwook ;
Sim, Kideok ;
Lee, Su-Gil ;
Jang, Hyun-Man .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) :1676-1679
[10]   A Novel Fault Location Method for a Cross-Bonded HV Cable System Based on Sheath Current Monitoring [J].
Li, Mingzhen ;
Zhou, Chengke ;
Zhou, Wenjun ;
Wang, Chunlin ;
Yao, Leiming ;
Su, Mengting ;
Huang, Xiaojun .
SENSORS, 2018, 18 (10)