Quasi-3-D Hybrid Analytical Method of Open-Circuit Stray Magnetic Field Considering Unsaturated Magnetic Permeability and End Leakage Flux

被引:0
作者
Wei, Yuhui [1 ]
Ma, Conggan [1 ]
Zhou, Shengsen [1 ]
Zhang, Xingxing [1 ]
An, Yuansheng [1 ]
Zhao, Liang [1 ]
Xu, Dongsheng [2 ]
机构
[1] Harbin Inst Technol Weihai, Weihai 264209, Peoples R China
[2] Shunyi Motor Co Ltd, Weihai 264209, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic cores; Magnetic fields; Permeability; Magnetic flux; Electromagnetic compatibility; Attenuation; Rotors; Motors; Magnetic circuits; Iron; End leakage flux; quasi-3-D hybrid analytical model; stray magnetic field (SMF); unsaturated magnetic permeability; AIR-GAP; SYNCHRONOUS MOTORS; DENSITY; TORQUE; FORCE; MODEL;
D O I
10.1109/TMECH.2025.3550503
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Motor fault diagnosis based on stray magnetic field (SMF) has broad prospects due to its noninvasive advantages. Rapid and accurate acquisition of SMF is crucial for fault diagnosis and mechanism analysis. However, unsaturated magnetic permeability of the iron core and end leakage flux are ignored in existing analytical models (AMs) of SMF, resulting in the inability to accurately calculate the three-dimensional (3-D) distribution of SMF. Motivated by this, this article proposes a quasi-3-D hybrid analytical method (HAM) of open-circuit stray magnetic field of external rotor permanent magnet motor (ERPMM). First, a quasi-3-D equivalent magnetic circuit model is established to calculate the air-gap magnetic field and end leakage flux at different axial positions. Second, the EMC models and iterative convergence algorithm are synergistically integrated to predict the unsaturated magnetic permeability at different axial positions of the rotor. Finally, a quasi-3-D virtual equivalent subdomain model is developed to calculate the 3-D distribution of SMF. The accuracy and efficiency of the proposed quasi-3-D HAM are verified through experiment and finite element model, respectively. This article provides a new approach for the analytical modeling of SMF of ERPMM.
引用
收藏
页数:12
相关论文
共 37 条
[1]   Stray Electromagnetic Field Distribution around Permanent Magnet Synchronous Motor Drive [J].
Adam, Ali Ahmed ;
Korolu, Selim ;
Gulez, Kayhan .
IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, :1669-+
[2]   Stray magnetic field distributed around a PMSM [J].
Adam, Ali Ahmed ;
Gulez, Kayhan ;
Koroglu, Selim .
TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2011, 19 (01) :119-131
[3]   Calculation Model of Armature Reaction Magnetic Field of Interior Permanent Magnet Synchronous Motor With Segmented Skewed Poles [J].
An, Yuansheng ;
Ma, Conggan ;
Zhang, Nic ;
Guo, Yue ;
Degano, Michele ;
Gerada, Chris ;
Bu, Feifei ;
Yin, Xiangrui ;
Li, Qiongyao ;
Zhou, Shengsen .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (02) :1115-1123
[4]   Open-Circuit Air-Gap Magnetic Field Calculation of Interior Permanent Magnet Synchronous Motor With V-Shaped Segmented Skewed Poles Using Hybrid Analytical Method [J].
An, Yuansheng ;
Ma, Conggan ;
Zhang, Nic ;
Guo, Yue ;
Degano, Michele ;
Gerada, Chris ;
Li, Qiongyao ;
Zhou, Shengsen .
IEEE TRANSACTIONS ON MAGNETICS, 2021, 57 (12)
[5]   An Improved Subdomain Model for Predicting the Magnetic Field of a Motor Containing Non-Orthogonal Boundaries [J].
Dong, Lieyi ;
Li, Wanyou ;
Shuai, Zhi-Jun .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (03) :2048-2057
[6]  
Fang L, 2005, ICEMS 2005: PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, P2124
[7]   A Stray Magnetic Flux-Based Robust Diagnosis Method for Detection and Location of Interturn Short Circuit Fault in PMSM [J].
Gurusamy, Vigneshwaran ;
Bostanci, Emine ;
Li, Chen ;
Qi, Yuan ;
Akin, Bilal .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
[8]   A New External Search Coil Based Method to Detect Detailed Static Air-Gap Eccentricity Position in Nonsalient Pole Synchronous Generators [J].
He, Yu-Ling ;
Zhang, Zhi-Jie ;
Tao, Wen-Qiang ;
Wang, Xiao-Long ;
Gerada, David ;
Gerada, Chris ;
Gao, Peng .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (08) :7535-7544
[9]   Analysis and Minimization of Detent End Force in Linear Permanent Magnet Synchronous Machines [J].
Hu, Hengzai ;
Liu, Xiangdong ;
Zhao, Jing ;
Guo, Youguang .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (03) :2475-2486
[10]   Rotor Fault Detection in Induction Motors Based on Time-Frequency Analysis Using the Bispectrum and the Autocovariance of Stray Flux Signals [J].
Iglesias-Martinez, Miguel E. ;
Alfonso Antonino-Daviu, Jose ;
Fernandez de Cordoba, Pedro ;
Alberto Conejero, J. .
ENERGIES, 2019, 12 (04)