Biomechanical evaluation of the effect of varying humeral implant length in total elbow replacement: a finite element analysis

被引:0
作者
Low, Jomain [1 ]
Pareatumbee, Pivatidevi [2 ]
Yew, Andy [2 ,3 ]
Tay, Kenny [2 ,3 ,4 ]
Sen Howe, Tet [2 ,3 ,4 ]
Thoreson, Andrew [5 ]
An, Kai-Nan [5 ]
Morrey, Bernard F. [5 ]
Koh, Joyce Suang Bee [2 ,3 ,4 ]
机构
[1] Duke NUS Med Sch, Singapore, Singapore
[2] Singapore Gen Hosp, Singhealth Duke NUS Musculoskeletal Sci Acad Clin, Singapore, Singapore
[3] Singapore Gen Hosp, Div Musculoskeletal Sci, Singapore, Singapore
[4] Singapore Gen Hosp, Dept Orthopaed Surg, Singapore, Singapore
[5] Mayo Clin, Rochester, MN USA
关键词
Total elbow replacement; stress shielding; implant length variations; finite element analysis; optimal implant length; stress distribution; ARTHROPLASTY; VALIDATION; OUTCOMES; TRENDS; MODEL;
D O I
10.1016/j.jse.2024.09.046
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total elbow arthroplasty (TEA) is increasingly used for expanding indications but complications like aseptic loosening and periprosthetic fractures persist. Our objective is to examine the biomechanical behavior of the total elbow implant in response to varying implant lengths by investigating the stresses and the stress shielding effect in the bone-implant assembly using finite element Methods: A fourth-generation synthetic humerus sawbone and its corresponding digital model were used in this study. Total elbow implants are laser scanned to obtain the 3D implant models. FE models of 2-mm cemented bone-prosthesis assemblies of different implant lengths were generated. While fixing the mid-humerus, a compressive load of 400 N was applied at the distal humerus at varying flexion angles of 60 degrees, 90 degrees, and 150 degrees to represent activities of daily living. A validated intact model was used to compare the experimental and computational strains. The von Mises stress, a scalar quantity that represents the state of stress the object is in, was then evaluated and compared in all intact and implanted models. Results: Longer humeral implants demonstrated larger areas of reduced peak stress, despite similar maximum cortical stress locations and magnitude. Cortical bone stress was observed to be lower along the implant insertion length. Maximum implant stress was also consistently higher in the 8-in implant for all loading conditions. Significant stress shielding was observed in all implants, with maximum %D stress consistently falling within the 15%-20% region of humerus length from the distal end. Discussion: Longer implants displayed larger stress-shielding areas, emphasizing the potential for shorter prostheses to preserve more bone stock and limit stress shielding. Level of evidence: Basic Science Study; Computer Modeling (c) 2024 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:1783 / 1791
页数:9
相关论文
共 24 条
[1]  
Badre Armin, 2021, J Clin Orthop Trauma, V18, P66, DOI 10.1016/j.jcot.2021.04.015
[2]   Aseptic loosening of femoral components - A review of current and future trends in materials used [J].
Bahraminasab, Marjan ;
Sahari, B. B. ;
Edwards, K. L. ;
Farahmand, Farzam ;
Arumugam, Manohar ;
Hong, Tang Sai .
MATERIALS & DESIGN, 2012, 42 :459-470
[3]   Finite element model validation based on an experimental model of the intact shoulder joint [J].
Bola, Margarida ;
Simoes, Jose ;
Ramos, Antonio .
MEDICAL ENGINEERING & PHYSICS, 2021, 87 :1-8
[4]   Biomechanical analysis of total elbow replacement with unlinked iBP prosthesis: An in vitro and finite element analysis [J].
Completo, A. ;
Pereira, J. ;
Fonseca, F. ;
Ramos, A. ;
Relvas, C. ;
Simoes, J. .
CLINICAL BIOMECHANICS, 2011, 26 (10) :990-997
[5]   Long-term outcomes of total elbow arthroplasty: a systematic review of studies at 10-year follow-up [J].
Davey, Martin S. ;
Hurley, Eoghan T. ;
Gaafar, Mohamed ;
Molony, Diarmuid ;
Mullett, Hannan ;
Pauzenberger, Leo .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (06) :1423-1430
[6]   Results after 562 total elbow replacements: A report from the Norwegian Arthroplasty Register [J].
Fevang, Bjorg-Tilde S. ;
Lie, Stein A. ;
Havelin, Leif I. ;
Skredderstuen, Arne ;
Furnes, Ove .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (03) :449-456
[7]   Development and experimental validation of a three-dimensional finite element model of the human scapula [J].
Gupta, S ;
van der Helm, FCT ;
Sterk, JC ;
van Keulen, F ;
Kaptein, BL .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2004, 218 (H2) :127-142
[8]  
Hackl M, 2017, ORTHOPADE, V46, P990, DOI 10.1007/s00132-017-3493-4
[9]   Effect of elbow implant design parameters on loosening: A finite element analysis [J].
Heidari, Milad ;
Rahmanivahid, Pooyan ;
Sharifi, Sayyed Nabi Al-Din ;
Hashemi, Mehdi ;
Mohammadian, Erfan ;
Akbari, Amir ;
Razaviyan, Zahrapanah .
REVISTA INTERNACIONAL DE METODOS NUMERICOS PARA CALCULO Y DISENO EN INGENIERIA, 2020, 36 (01)
[10]  
Kholinne Erica, 2021, J Clin Orthop Trauma, V19, P42, DOI 10.1016/j.jcot.2021.05.008