Comparative studies on blast resistance of precast concrete composite and cast-in-place slabs

被引:0
作者
Chen, G. Q. [1 ]
Wu, H. [1 ]
Cheng, Y. H. [1 ]
Lu, J. X. [1 ]
机构
[1] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Blast resistance; Precast concrete composite slab; RC slab; Field explosion test; Numerical simulation; DYNAMIC-RESPONSE; RC SLABS;
D O I
10.1016/j.jobe.2025.113077
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Precast concrete composite (PCC) slabs with truss rebars have been widely applied in modern civil engineering attributed to their advantages over traditional cast-in-place reinforced concrete (RC) slabs in constructional industrialization and environmental protection. With the increasing aggravations of blast-induced catastrophic incidents, there is a lack of understanding on the blast resistance of PCC slabs. This study aims to perform a comprehensive evaluation on the dynamic behaviors of both PCC and RC slabs against blast loadings. Firstly, by designing a blast loading test apparatus, the field explosion test was conducted on six PCC and RC slabs with three identical scaled distances of TNT explosive. The incident and reflected overpressures-time histories, as well as damage patterns and deflection-time histories of slabs were recorded. Secondly, by adopting the Multi-Material Arbitrary Lagrangian-Eulerian and Fluid-Structure Interaction algorithms, a finite element analysis approach was proposed and fully validated by comparison to the overpressures of blast wave, deflections and failure modes of slabs in both the present and existing explosion tests. Finally, the prototype PCC and RC slabs in frame building structures were designed, and the corresponding blast resistance against three typical design-based threats of explosion specified by the U.S. Federal Emergency Management Agency was examined. It indicates that, under the near-range explosion of briefcase bomb (23 kg TNT), the maximum deflection at the 1/4 span of the prototype PCC slab is 36 % less than that of the RC slab. Considering the superior blast resistance of PCC slabs, the traditional RC slabs could be replaced by PCC slabs for the prefabricated blast-resistant buildings.
引用
收藏
页数:19
相关论文
共 34 条
[1]  
American Concrete Institute, 2005, Building Code Requirements for Structural Concrete (ACI 318-05) and Commentary (ACI 318R-05)
[2]   Size effect on reinforced concrete slabs under direct contact explosion [J].
Cai, Runze ;
Li, Yanzhao ;
Zhang, Chunxiao ;
Cao, Hai ;
Qi, Hui ;
Mao, Jize .
ENGINEERING STRUCTURES, 2022, 252
[3]   Air blast resistance of full-scale slabs with different compositions: Numerical modeling and field validation [J].
Castedo, R. ;
Segarra, P. ;
Alanon, A. ;
Lopez, L. M. ;
Santos, A. P. ;
Sanchidrian, J. A. .
INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2015, 86 :145-156
[4]  
China Association for Engineering Construction Standardization, 2020, T/CECS 715-2020
[5]  
China Concrete and Cement-based Products Association, 2018, China precast concrete industry steps into "a new era
[6]  
Euro-International Committee for Concrete, 1990, CEB-FIP MODEL CODE
[7]  
Federal Emergency Management Agency (FEMA), 1996, FEMA-277
[8]   Experimental research on blast-resistance of one-way concrete slabs reinforced by BFRP bars under close-in explosion [J].
Feng, Jiang ;
Zhou, Yinzhi ;
Wang, Peng ;
Wang, Bo ;
Zhou, Jiannan ;
Chen, Hailong ;
Fan, Hualin ;
Jin, Fengnian .
ENGINEERING STRUCTURES, 2017, 150 :550-561
[9]  
Guo J.J., 2003, Study on Mechanics Performance of Adherence of Young on Old Concrete after High Temperature
[10]  
Hallquist J.Q., 2007, LS-DYNA Keyword User's Manual, V970