Optimizing Radiation Dose in High-Resolution Chest CT: The Impact of Patient-Specific Factors and Size-Specific Dose Estimates

被引:3
作者
Abuzaid, Mohamed [1 ,2 ]
机构
[1] Univ Sharjah, Coll Hlth Sci, Med Diag Imaging Dept, POB 27272, Sharjah, U Arab Emirates
[2] Univ Sharjah, Res Inst Med & Hlth Sci, POB 27272, Sharjah, U Arab Emirates
关键词
HRCT; computed tomography; CT dose index; dose-length product; radiation dose; size-specific dose estimates; EXPOSURE; ADULT; ORGAN;
D O I
10.3390/diagnostics15060740
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: High-resolution chest computed tomography (HRCT) is a critical diagnostic tool, but radiation dose optimization remains a significant concern. Traditional dose metrics such as the volume CT dose index (CTDIvol) and dose-length product (DLP) do not adequately account for patient size variations. This study aimed to assess the radiation dose in HRCT using size-specific dose estimates (SSDEs) and evaluate the influence of patient-specific factors on key dosimetric parameters. Methods: This retrospective cohort study analyzed HRCT scans from 1970 adult patients conducted between September 2022 and February 2024. Radiation dose data, including the CTDIvol, DLP, SSDE, and effective dose, were extracted from the DoseWatch (TM) software. Patient demographics, scan protocols, and exposure parameters were collected. Descriptive statistics, correlation analyses, and significance testing were conducted using IBM SPSS (Version 26). Results: A significant positive correlation was found between the radiation dose parameters (CTDIvol, DLP, SSDE) and patient body size metrics, particularly BMI (rpb = 0.445, p < 0.01). The SSDE values ranged from 2.7 to 12.4 mGy, providing a more patient-specific dose assessment than traditional indices. Gender differences were observed, with male patients receiving higher radiation doses (p < 0.01). The scanning range exhibited a significant negative correlation with the CTDIvol and SSDE, suggesting dose variations with anatomical coverage. Conclusions: SSDEs provide a more accurate, patient-centered dose assessment in HRCT, allowing for optimized radiation safety strategies. These findings emphasize the need for size-adapted scan protocols to minimize exposure while maintaining diagnostic image quality. The routine integration of SSDE into clinical practice is recommended to enhance individualized dose management in HRCT.
引用
收藏
页数:10
相关论文
共 27 条
[1]  
Abuzaid Mohammed Mahmoud, 2024, 2024 Advances in Science and Engineering Technology International Conferences (ASET), P1, DOI 10.1109/ASET60340.2024.10708642
[2]   Optimizing CT Abdomen-Pelvis Scan Radiation Dose: Examining the Role of Body Metrics (Waist Circumference, Hip Circumference, Abdominal Fat, and Body Mass Index) in Dose Efficiency [J].
Almohammed, Huda I. ;
Elshami, Wiam ;
Hamd, Zuhal Y. ;
Abuzaid, Mohamed .
TOMOGRAPHY, 2024, 10 (05) :643-653
[3]   Investigating the Effect of Patient-Related Factors on Computed Tomography Radiation Dose Using Regression and Correlation Analysis [J].
Alshurbaji, Mohammad ;
El Haout, Sara ;
Chanchal, Akchunya ;
Dhou, Salam ;
Dalah, Entesar .
APPLIED SCIENCES-BASEL, 2024, 14 (03)
[4]   How to Appropriately Calculate Effective Dose for CT Using Either Size-Specific Dose Estimates or Dose-Length Product [J].
Brady, Samuel L. ;
Mirro, Amy E. ;
Moore, Bria M. ;
Kaufman, Robert A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (05) :953-958
[5]  
Brat H., 2019, EuroSafe Imaging, V2019, P1, DOI [10.26044/esi2019/ESI-0043, DOI 10.26044/ESI2019/ESI-0043]
[6]   High-resolution computed tomography manifestations of COVID-19 infections in patients of different ages [J].
Chen, Zuhua ;
Fan, Hongjie ;
Cai, Jian ;
Li, Yunjiang ;
Wu, Baoliang ;
Hou, Yanchun ;
Xu, Shufeng ;
Zhou, Fei ;
Liu, Yongguang ;
Xuan, Weiling ;
Hu, Hongjie ;
Sun, Jihong .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126
[7]   VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients [J].
Ding, Aiping ;
Gao, Yiming ;
Liu, Haikuan ;
Caracappa, Peter F. ;
Long, Daniel J. ;
Bolch, Wesley E. ;
Liu, Bob ;
Xu, X. George .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (14) :5601-5625
[8]   Patient-specific organ and effective dose estimates in pediatric oncology computed tomography [J].
Gao, Yiming ;
Quinn, Brian ;
Pandit-Taskar, Neeta ;
Behr, Gerald ;
Mahmood, Usman ;
Long, Daniel ;
Xu, X. George ;
St.Germain, Jean ;
Dauer, Lawrence T. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 :146-155
[9]   Dosimetric and radiation cancer risk evaluation of high resolution thorax CT during COVID-19 outbreak [J].
Ghetti, C. ;
Ortenzia, O. ;
Maddalo, M. ;
Altabella, L. ;
Sverzellati, N. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 :119-124
[10]   Relationships of Radiation Dose Indices with Body Size Indices in Adult Body Computed Tomography [J].
Inoue, Yusuke ;
Itoh, Hiroyasu ;
Nagahara, Kazunori ;
Hata, Hirofumi ;
Mitsui, Kohei .
TOMOGRAPHY, 2023, 9 (04) :1381-1392