Effects of local enemal matrix protein on osseointegration of different surface Titanium implants

被引:0
作者
Istek, Ozmen [1 ]
Sokmen, Kevser [2 ]
Ozcan, Erhan Cahit [3 ]
Tanrisever, Murat [4 ]
Gelic, Turker [4 ]
Can, Umit Koray [5 ]
Bozoglan, Alihan [6 ]
Dundar, Serkan [6 ,7 ]
机构
[1] Mus Alparslan Univ, Fac Hlth Sci, Dept Nursing, Mus, Turkiye
[2] Alanya Alaaddin Keykubat Univ, Fac Dent, Dept Periodontol, Antalya, Turkiye
[3] Firat Univ, Fac Med, Dept Estet Plast & Reconstruct Surg, Elazig, Turkiye
[4] Firat Univ, Fac Vet, Dept Surg, Elazig, Turkiye
[5] Turkish Jockey Club, Elazig, Turkiye
[6] Firat Univ, Fac Dent, Dept Periodontol, Elazig, Turkiye
[7] Firat Univ, Inst Sci, Dept Stat, Elazig, Turkiye
来源
REVISTA CIENTIFICA-FACULTAD DE CIENCIAS VETERINARIAS | 2025年 / 35卷 / 02期
关键词
Local enamel matrix protein; titanium implant; osseointegration; bone implant connection; bone implant contact; DRIED BONE ALLOGRAFT; INTRABONY PERIODONTAL DEFECTS; OSSEOUS DEFECTS; COMBINATION; ACID;
D O I
10.52973/rcfcv-e35625
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The aim of this study is to investigate the osseointegration levels of implants with different surfaces locally applied with enamel matrix protein by biomechanical methods. Thirty adult female Spraque Dawley rats weighing 300-350 g were included in the study as subjects. The rats were divided into 3 groups with 10 rats in each group: Machined Surface Group (n = 10), Sandblasted Large Acid Grid (SLA) Surface Group (n = 10) and Resorbable Blasting Material (RBM) Surface Group (n = 10). Titanium implants were surgically placed in the right tibias of the rats with sterile physiological serum cooling. Immediately before the implants were placed, local enamel matrix protein was applied to the prepared sockets and then the implants were placed. The rats were euthanized after waiting for osseointegration for four weeks and the implants were taken with the surrounding bone tissues after the soft tissues were removed. The bone-implant contact of all implants was analyzed by biomechanical method and recorded in Newton<middle dot>cm-1(N<middle dot>cm-1). When the obtained biomechanical data were examined, the average bone-implant contact value was found to be 2.24 +/- 0.67 (N<middle dot>cm-1) in machined surface implants, 4.5 +/- 1.36 (N<middle dot>cm-1) in SLA surface implants and 3.24 +/- 0.94 (N<middle dot>cm-1) in RBM surface implants. A statistically difference was detected between machined surface implants and SLA surface implants (P<0.05; P=0.02). It can be stated that local enamel matrix protein application may increase bone-implant connection in SLA surface implants.
引用
收藏
页数:6
相关论文
共 30 条
[1]   Effects of the Application Local Zoledronic Acid On Different Dental Implants in Rats On Osseointegration [J].
Bingul, Muhammet Bahattin ;
Gul, Mehmet ;
Dundar, Serkan ;
Bozoglan, Alihan ;
Kirtay, Mustafa ;
Ozupek, Muhammet Fatih ;
Ozcan, Erhan Cahit ;
Habek, Osman ;
Tasdemir, Ismail .
DRUG DESIGN DEVELOPMENT AND THERAPY, 2024, 18 :2249-2256
[2]   Porcine fetal enamel matrix derivative enhances bone formation induced by demineralized freeze dried bone allograft in vivo [J].
Boyan, BD ;
Weesner, TC ;
Lohmann, CH ;
Andreacchio, D ;
Carnes, DL ;
Dean, DD ;
Cochran, DL ;
Schwartz, Z .
JOURNAL OF PERIODONTOLOGY, 2000, 71 (08) :1278-1286
[3]  
BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
[4]   Long-term follow-up of turned single implants placed in periodontally healthy patients after 16-22 years: radiographic and peri-implant outcome [J].
Dierens, M. ;
Vandeweghe, S. ;
Kisch, J. ;
Nilner, K. ;
De Bruyn, H. .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (02) :197-204
[5]   Effects of restraint stress and high-fat diet on osseointegration of titanium implants: an experimental study [J].
Dundar, Serkan ;
Bozoglan, Alihan ;
Bulmus, Ozgur ;
Tekin, Samet ;
Yildirim, Tuba Talo ;
Kirtay, Mustafa ;
Toy, Vesile Elif ;
Gul, Mehmet ;
Bozoglan, Merve Yilmaz .
BRAZILIAN ORAL RESEARCH, 2020, 34
[6]   Comparison of Osseointegration of Five Different Surfaced Titanium Implants [J].
Dundar, Serkan ;
Yaman, Ferhan ;
Bozoglan, Alihan ;
Yildirim, Tuba Talo ;
Kirtay, Mustafa ;
Ozupek, Muhammet Fatih ;
Artas, Gokhan .
JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (07) :1991-1995
[7]  
Elkhaweldi A, 2014, J. Oral Bio. Internet, V1, P8, DOI pmw7
[8]   Combination of Enamel Matrix Derivatives with Bone Graft vs Bone Graft Alone in the Treatment of Periodontal Intrabony and Furcation Defects: A Systematic Review and Meta-Analysis [J].
Fidana, Ibrahim ;
Labreucheb, Julien ;
Huck, Olivier ;
Agossad, Kevimy .
ORAL HEALTH & PREVENTIVE DENTISTRY, 2024, 22 (01) :655-664
[9]   Multifactorial Evaluation of Implant Failure: A 19-year Retrospective Study [J].
Han, Hyun-Jin ;
Kim, Sungtae ;
Han, Dong-Hoo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (02) :303-310
[10]   Prospective assessment of the use of enamel matrix proteins with minimally invasive surgery [J].
Harrel, SK ;
Wilson, TG ;
Nunn, ME .
JOURNAL OF PERIODONTOLOGY, 2005, 76 (03) :380-384