Temperature-guided high and very high-power short duration ablation for atrial fibrillation treatment: the peQasus multicentre study

被引:1
作者
Heeger, Christian-Hendrik [1 ,2 ,3 ]
Almorad, Alexandre [4 ,5 ]
Scherr, Daniel [6 ]
Szegedi, Nandor [7 ]
Seidl, Sebastian [8 ]
Baran, Jakub [9 ,10 ]
Duytschaever, Mattias
Gupta, Dhiraj [12 ]
Linz, Dominik [13 ]
Lyan, Evgeny [14 ]
Rocca, Domenico Della [4 ]
Geller, Laszlo [7 ]
Knecht, Sebastien [11 ]
Calvert, Peter [12 ]
Meilak, Samuel [15 ,16 ]
Leventopoulos, Georgios [17 ]
Popescu, Sorin Stefan [2 ]
Rauber, Martin [6 ,18 ]
Kollias, Georgios [19 ]
Niedzwiedz, Michal [10 ]
Sarkozy, Andrea [4 ,5 ]
Badoz, Marc [20 ]
Manninger-Wuenscher, Martin [6 ]
Sciacca, Vanessa [21 ]
Sohns, Christian [21 ]
Ginks, Matthew R. [22 ]
Puererfellner, Helmut
Tilz, Roland R. [2 ,3 ]
机构
[1] Asklepios Klin Hamburg Altona, Dept Rhythmol Cardiol & Internal Med, Paul Ehrlich Str 1, D-22763 Hamburg, Germany
[2] Univ Hosp Schleswig Holstein, Univ Heart Ctr Lubeck, Dept Rhythmol, Ratzeburger Allee 160, D-23538 Lubeck, Germany
[3] German Ctr Cardiovasc Res, Partner Site Hamburg Kiel Luebeck, Lubeck, Germany
[4] Vrije Univ Brussel, Univ Ziekenhuis Brussel, Heart Rhythm Management Ctr, Postgrad Program Cardiac Electrophysiol & Pacing, Brussels, Belgium
[5] European Reference Networks Guard Heart, Laarbeeklaan 101, B-1090 Brussels, Belgium
[6] Karl Franzens Univ Graz, Dept Cardiol, Graz, Austria
[7] Semmelweis Univ, Heart & Vasc Ctr, Budapest, Hungary
[8] Ordensklinikum Linz Elisabethinen, Linz, Austria
[9] Med Univ Warsaw, Univ Clin Ctr, Dept Internal Med & Cardiol, Warsaw, Poland
[10] Grochowski Hosp, Ctr Postgrad Med Educ, Dept Cardiol, Div Clin Electrophysiol, Warsaw, Poland
[11] AZ St Jan Hosp, Dept Cardiol, Brugge, Belgium
[12] Univ Liverpool, Liverpool Heart & Chest Hosp, Fac Hlth & Life Sci, Liverpool, England
[13] Maastricht Univ, Med Ctr, Dept Cardiol, Maastricht, Netherlands
[14] Univ Hosp Schleswig Holstein, Univ Heart Ctr Kiel, Kiel, Germany
[15] Oxford Univ Hosp NHS Fdn Trust, Oxford, England
[16] John Radcliffe Hosp, Oxford, England
[17] Univ Hosp Patras, Dept Cardiol, Patras, Greece
[18] Med Univ Ljubljana, Dept Cardiol, Ljubljana, Slovenia
[19] Ordensklinikum Linz Elisabethinen, Abt Innere Med Kardiol Angiol & Intens Med 2, Linz, Austria
[20] Univ Hosp Besancon, Dept Cardiol, Besancon, France
[21] Ruhr Univ Bochum, Univ Klin, Herz & Diabet Zentrum NRW, Bad Oeynhausen, Germany
[22] Oxford Univ Hosp NHS Fdn Trust, Dept Cardiol, Oxford, England
来源
EUROPACE | 2025年 / 27卷 / 06期
关键词
Atrial fibrillation; High-power short duration; Pulmonary vein isolation; Radiofrequency; Acute efficacy; PULMONARY VEIN ISOLATION; RADIOFREQUENCY ABLATION; CRYOBALLOON; SINGLE;
D O I
10.1093/europace/euae284
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Temperature-controlled high-power short-duration (HPSD) radiofrequency catheter ablation for pulmonary vein isolation (PVI) utilizing a novel ablation catheter (QDOT Micro) with real-time assessment of catheter tip temperature aims for safer, more effective, and faster procedures. Methods and results The peQasus study is a large European multicentre study set up to assess safety, acute efficacy, and outcomes of temperature-controlled HPSD-based PVI. The primary endpoints were safety, efficacy, and 12-month freedom from atrial tachyarrhythmias. Additionally, two strategies namely very HPSD (90 W for 4 s) only and a hybrid approach (HPSD with maximum of 50 W and vHPSD) were compared. A total of 1023 AF patients in 15 centres from nine European countries received PVI with the QDOT. Complete PVI was successfully achieved in all patients. In 699/1023 (68.3%), the vHPSD-only approach (vHPSD group) and in 324/ (31.7%) patients, the hybrid approach (hybrid group) was utilized. The mean procedure duration was 98.4 +/- 37.4 min (vHPSD: 88.2 +/- 34.9 min, hybrid: 117.4 +/- 32.7 min, P < 0.001). The first-pass isolation rate of all PVs was 64% (vHPSD: 62.6%, hybrid: 67.1%, P = 0.187). Severe adverse events were observed in 1.7% (vHPSD: 1.6%, hybrid: 1.9%, P = 0.746). Twelve-month arrhythmia-recurrence-free survival was 77.1% (vHPSD: 76.8%, hybrid: 77.8%, P = 0.241). Conclusion In this large multicentre study, temperature-controlled HPSD and vHPSD ablation via a novel ablation catheter provides safe and effective PVI with a relatively short procedure duration. Despite a shorter procedure time, no differences in terms of safety and freedom from arrhythmia recurrence were found irrespective of utilizing vHPSD or the hybrid approach.
引用
收藏
页数:11
相关论文
共 38 条
[1]   High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability [J].
Barkagan, Michael ;
Contreras-Valdes, Fernando M. ;
Leshem, Eran ;
Buxton, Alfred E. ;
Nakagawa, Hiroshi ;
Anter, Elad .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (09) :1287-1296
[2]   Progress in atrial fibrillation ablation during 25 years of Europace journal [J].
Boersma, Lucas ;
Andrade, Jason G. ;
Betts, Tim ;
Duytschaever, Mattias ;
Purerfellner, Helmut ;
Santoro, Francesco ;
Tzeis, Stylianos ;
Verma, Atul .
EUROPACE, 2023, 25 (09)
[3]   Incidence and predictors of stroke and silent cerebral embolism following very high-power short-duration atrial fibrillation ablation [J].
Boga, Marton ;
Suhai, Ferenc Imre ;
Orban, Gabor ;
Sallo, Zoltan ;
Nagy, Klaudia Vivien ;
Szegedi, Levente ;
Jokkel, Zsofia ;
Csore, Judit ;
Osztheimer, Istvan ;
Perge, Peter ;
Gupta, Dhiraj ;
Merkely, Bela ;
Geller, Laszlo ;
Szegedi, Nandor .
EUROPACE, 2023, 25 (11)
[4]   High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics [J].
Bourier, Felix ;
Duchateau, Josselin ;
Vlachos, Konstantinos ;
Lam, Anna ;
Martin, Claire A. ;
Takigawa, Masateru ;
Kitamura, Takeshi ;
Frontera, Antonio ;
Cheniti, Ghassen ;
Pambrun, Thomas ;
Klotz, Nicolas ;
Denis, Arnaud ;
Derval, Nicolas ;
Cochet, Hubert ;
Sacher, Frederic ;
Hocini, Meleze ;
Haissaguerre, Michel ;
Jais, Pierre .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (11) :1570-1575
[5]   Catheter ablation of atrial fibrillation using ablation index-guided high-power technique: Frankfurt AI high-power 15-month follow-up [J].
Chen, Shaojie ;
Schmidt, Boris ;
Bordignon, Stefano ;
Tohoku, Shota ;
Urban, Verena C. ;
Schulte-Hahn, Britta ;
Chun, K. R. Julian .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (03) :616-624
[6]   Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-Ttrial [J].
Chun, K. R. Julian ;
Stich, Marie ;
Fuernkranz, Alexander ;
Bordignon, Stefano ;
Perrotta, Laura ;
Dugo, Daniela ;
Bologna, Fabrizio ;
Schmidt, Boris .
HEART RHYTHM, 2017, 14 (04) :495-500
[7]   Pulmonary Vein Reconnection No Longer Occurs in the Majority of Patients After a Single Pulmonary Vein Isolation Procedure [J].
De Pooter, Jan ;
Strisciuglio, Teresa ;
El Haddad, Milad ;
Wolf, Michael ;
Phlips, Thomas ;
Vandekerckhove, Yves ;
Tavernier, Rene ;
Knecht, Sebastien ;
Duytschaever, Mattias .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (03) :295-305
[8]   Accessory pathway ablation with a new ablation catheter containing microelectrodes and facilitating very-high-power short-duration ablation [J].
Eitel, Charlotte ;
Heeger, Christian-Hendrik ;
Vogler, Julia ;
Tilz, Roland Richard .
EUROPEAN HEART JOURNAL-CASE REPORTS, 2022, 7 (01)
[9]   Optimized lesion geometry using very high-power short-duration ablation in catheter ablation adjacent to the phrenic nerve [J].
Fink, Thomas ;
Sohns, Christian ;
Sciacca, Vanessa ;
Sommer, Philipp ;
Bergau, Leonard .
EUROPACE, 2022, 24 (10) :1568
[10]   Safety of very high-power short-duration radiofrequency ablation for pulmonary vein isolation: a two-centre report with emphasis on silent oesophageal injury [J].
Halbfass, Philipp ;
Wielandts, Jean-Yves ;
Knecht, Sebastien ;
de Waroux, Jean-Benoit Le Polain ;
Tavernier, Rene ;
De Wilde, Vincent ;
Sonne, Kai ;
Nentwich, Karin ;
Ene, Elena ;
Berkovitz, Artur ;
Mueller, Julian ;
Lehmkuhl, Lukas ;
Reichart, Amelie ;
Lusebrink, Ulrich ;
Duytschaever, Mattias ;
Deneke, Thomas .
EUROPACE, 2022, 24 (03) :400-405