Efficacy of Using a Vessel Dilator during Surgery to Evaluate Vein Diameter and Predict Radiocephalic Arteriovenous Fistula Maturation and Patency

被引:0
作者
Takai, Kanako [1 ]
Nojima, Takehisa [2 ]
Taguchi, Hidehiko [3 ]
Hasegawa, Kosei [4 ]
Yamauchi, Takashi [5 ]
机构
[1] Higashiosaka City Med Ctr, Dept Cardiovasc Surg, Higashiosaka, Osaka 5788588, Japan
[2] Nojima Vasc Access Clin, Kobe, Hyogo 6512273, Japan
[3] Higashiosaka City Med Ctr, Dept Radiol, Higashiosaka, Osaka 5788588, Japan
[4] Sapporo Makomanai Hosp, Dept Cardiovasc Surg, Sapporo, Hokkaido 0050013, Japan
[5] Osaka Univ, Dept Cardiovasc Surg, Grad Sch Med, Suita, Osaka 5650871, Japan
来源
SURGERIES | 2024年 / 5卷 / 04期
关键词
arteriovenous fistula creation; vein diameter; vessel dilator; patency; maturation; CEPHALIC VEIN; HEMODIALYSIS; AVF;
D O I
10.3390/surgeries5040076
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: We use vessel dilators to assess the diameter of the target vein during surgery for arteriovenous fistula (AVF) creation in hemodialysis patients. This study investigates the efficacy of using vein diameter as measured using dilators (surgical diameter; SD) versus that as measured by preoperative ultrasonography (ultrasonographic diameter; UD) to predict postoperative complications and patency. Methods: Sixty-three patients who underwent radiocephalic AVF creation and had measurements of UD and SD were retrospectively analyzed. Cutoff values for UD and SD regarding complications were used to dichotomize the patients into high and low groups for comparisons. Results: The 2-year primary and secondary patency rates overall were 66.5% and 88.9%, respectively. The optimal UD and SD cutoff values were 2.4 and 3.5 mm, respectively. The 2-year primary patency rate was higher in the high-SD group than the low-SD group (88.2% vs. 58.6%; p = 0.0426). The 2-year secondary patency rate was significantly higher in the high-UD/high-SD group than the low-UD/low-SD group (91.7% vs. 68.4%; p = 0.0067). Conclusions: Intraoperative measurement of vein diameter using dilators during AVF creation might be a useful method of predicting patency, particularly when SD is used in combination with UD.
引用
收藏
页码:948 / 955
页数:8
相关论文
共 22 条
[1]   The role of venous diameter in predicting arteriovenous fistula maturation: When not to expect an AVF to mature according to pre-operative vein diameter measurements? A best evidence topic [J].
Bashar, K. ;
Clarke-Moloney, M. ;
Burke, P. E. ;
Kavanagh, E. G. ;
Walsh, S. R. .
INTERNATIONAL JOURNAL OF SURGERY, 2015, 15 :95-99
[2]   Arteriovenous fistula in dialysis patients: Factors implicated in early and late AVF maturation failure [J].
Bashar, Khalid ;
Conlon, Peter J. ;
Kheirelseid, Elrasheid A. H. ;
Aherne, Thomas ;
Walsh, Stewart R. ;
Leahy, Austin .
SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2016, 14 (05) :294-300
[3]   Arteriovenous Fistulae for Haemodialysis: A Systematic Review and Meta analysis of Efficacy and Safety Outcomes [J].
Bylsma, L. C. ;
Gage, S. M. ;
Reichert, H. ;
Dahl, S. L. M. ;
Lawson, J. H. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2017, 54 (04) :513-522
[4]   Routine Preoperative Vascular Ultrasound Improves Patency and Use of Arteriovenous Fistulas for Hemodialysis: A Randomized Trial [J].
Ferring, Martin ;
Claridge, Martin ;
Smith, Steven A. ;
Wilmink, Teun .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2010, 5 (12) :2236-2244
[5]   Preoperative point-of-care ultrasound and its impact on arteriovenous fistula maturation outcomes [J].
Hossain, Sajjid ;
Sharma, Amit ;
Dubois, Luc ;
DeRose, Guy ;
Duncan, Audra ;
Power, Adam H. .
JOURNAL OF VASCULAR SURGERY, 2018, 68 (04) :1157-1165
[6]   The clinical utility of vascular mapping with Doppler ultrasound prior to arteriovenous fistula construction for hemodialysis access [J].
Ilhan, Gokhan ;
Esi, Ertap ;
Bozok, Sahin ;
Yurekli, Ismail ;
Ozpak, Berkan ;
Ozelci, Ahmet ;
Destan, Bugra ;
Gurbuz, Ali .
JOURNAL OF VASCULAR ACCESS, 2013, 14 (01) :83-88
[7]   The anastomosis of the arteriovenous fistula - common errors and their avoidance [J].
Konner, K .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2002, 17 (03) :376-379
[8]   Comparative Analysis of Cellular Phenotypes Within the Neointima From Vein Segments Collected Prior to Vascular Access Surgery and Stenotic Arteriovenous Dialysis Accesses [J].
Lee, Timmy ;
Wang, Yang ;
Arend, Lois ;
Cornea, Virgilius ;
Campos, Begona ;
Munda, Rino ;
Roy-Chaudhury, Prabir .
SEMINARS IN DIALYSIS, 2014, 27 (03) :303-309
[9]   KDOQI CLINICAL PRACTICE GUIDELINE FOR VASCULAR ACCESS: 2019 UPDATE [J].
Lok, Charmaine E. ;
Huber, Thomas S. ;
Lee, Timmy ;
Shenoy, Surendra ;
Yevzlin, Alexander S. ;
Abreo, Kenneth ;
Allon, Michael ;
Asif, Arif ;
Astor, Brad C. ;
Glickman, Marc H. ;
Graham, Janet ;
Moist, Louise M. ;
Rajan, Dheeraj K. ;
Roberts, Cynthia ;
Vachharajani, Tushar J. ;
Valentini, Rudolph P. .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2020, 75 (04) :S1-S164
[10]   Surveillance of arteriovenous accesses with the use of duplex Doppler ultrasonography [J].
Malik, Jan ;
Kudlicka, Jaroslav ;
Novakova, Ludmila ;
Adamec, Josef ;
Malikova, Hana ;
Kavan, Jan .
JOURNAL OF VASCULAR ACCESS, 2014, 15 :S28-S32