Comparison of clinical efficacy between proximal femoral locking plate and cannulated compression screws for femoral neck fracture

被引:0
作者
Zhou, Xianglong [1 ]
Wei, Dongxuan [1 ]
Xiao, Jiheng [1 ]
Xia, Tianyi [1 ]
Zhou, Haoran [1 ]
Xiang, Jianhui [1 ]
Fang, Hanhong [1 ]
Song, Hui [1 ]
Xiong, Liming [1 ]
机构
[1] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Orthopaed, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
hip fracture; femoral neck fracture; internal fixation; proximal femoral locking plate; cannulated compression screws; INTRACAPSULAR HIP FRACTURE; INTERNAL-FIXATION; MANAGEMENT; ARTHROPLASTY; MULTICENTER;
D O I
10.3389/fsurg.2025.1546873
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The objective of this study is to investigate the clinical efficacy of proximal femoral locking plates in comparison to cannulated compression screws for the treatment of femoral neck fractures. Methods: A retrospective analysis of clinical data from 50 patients with femoral neck fractures treated at the Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology from September 2018 to June 2023. Patients were divided into 25 in the PFLP group and 25 in the CCS group. A comparison was made between the two groups in terms of the following variables: basic characteristics, perioperative information, and information during follow-up visits. Results: The basic characteristics of the two groups were found to exhibit no statistically significant differences (P > 0.05). The PFLP group had significantly longer surgical times and greater Intraoperative hemorrhage loss compared to the CCS group (P < 0.05). The statistical analysis revealed that there were no significant differences in intraoperative fluoroscopy times and Garden index between the two groups (P > 0.05). The PFLP group exhibited a markedly superior fracture healing time, femoral neck shortening, and Harris hip scores in comparison to the CCS group (P < 0.05). The postoperative complication rates were 12% in the PFLP group and 20% in the CCS group, with no statistically significant difference (P > 0.05). Conclusion: The results of this retrospective study suggest that the PFLP group demonstrated superior outcomes compared to the CCS group in several key areas, including fracture healing time, preservation of femoral neck length, recovery of hip function, and incidence of postoperative complications.
引用
收藏
页数:10
相关论文
共 41 条
[31]   A systematic review of undisplaced femoral neck fracture treatments for patients over 65 years of age, with a focus on union rates and avascular necrosis [J].
Xu, Dan-Feng ;
Bi, Fang-Gang ;
Ma, Chi-Yuan ;
Wen, Zheng-Fa ;
Cai, Xun-Zi .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
[32]   Arthroplasty versus Internal Fixation for Displaced Intracapsular Femoral Neck Fracture in the Elderly: Systematic Review and Meta-analysis of Short- and Long-term Effectiveness [J].
Ye, Chen-Yi ;
Liu, An ;
Xu, Ming-Yuan ;
Nonso, Nwofor Samuel ;
He, Rong-Xin .
CHINESE MEDICAL JOURNAL, 2016, 129 (21) :2630-2638
[33]   Is dynamic locking plate(Targon FN) a better choice for treating of intracapsular hip fracture? A meta-analysis [J].
Yin, Hao ;
Pan, Zhengjun ;
Jiang, Hua .
INTERNATIONAL JOURNAL OF SURGERY, 2018, 52 :30-34
[34]  
Yu X, 2020, Zhonghua Yi Xue Za Zhi, V100, P2628, DOI 10.3760/cma.j.cn112137-20200219-00364
[35]   Treatment of a femoral neck fracture combined with ipsilateral femoral head and intertrochanteric fractures: A case report [J].
Yu, Xiang ;
Li, Yu-Zhi ;
Lu, Hai-Jian ;
Liu, Bing-Li .
WORLD JOURNAL OF ORTHOPEDICS, 2024, 15 (10) :973-980
[36]   Efficacy of four internal fixation devices on femoral neck fractures in young adults: A systematic review and network meta-analysis [J].
Yuan, Daotong ;
Zhang, Zhimeng ;
Wang, Xu ;
Chang, Wenjie ;
Xie, Wenpeng ;
Zhang, Yongkui .
MEDICINE, 2024, 103 (45)
[37]   Incidence of and trends in hip fracture among adults in urban China: A nationwide retrospective cohort study [J].
Zhang, Chenggui ;
Feng, Jingnan ;
Wang, Shengfeng ;
Gao, Pei ;
Xu, Lu ;
Zhu, Junxiong ;
Jial, Jialin ;
Liu, Lili ;
Liu, Guozhen ;
Wang, Jinxi ;
Zhan, Siyan ;
Song, Chunli .
PLOS MEDICINE, 2020, 17 (08)
[38]   Biomechanical effects of FNS on femoral neck fractures based on different reduction quality: finite element analysis [J].
Zhang, Xu ;
Zhang, Yazhong ;
Huang, Shaolong ;
Qi, Xiangyu ;
Li, Wenbo ;
Lv, Yongxiang ;
Zhu, Ziqiang .
BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
[39]   Reoperation rate and implants' position variation features of displaced femoral neck fractures with sliding compression or length-stable fixation in young and middle-aged population [J].
Zhu, Xiao-Zhong ;
Wang, Wei ;
Wu, Sheng-Hui ;
Mei, Jiong .
BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
[40]   Femoral Neck Shortening After Internal Fixation of a Femoral Neck Fracture [J].
Zielinski, Stephanie M. ;
Keijsers, Noel L. ;
Praet, Stephan F. E. ;
Heetveld, Martin J. ;
Bhandari, Mohit ;
Wilssens, Jean Pierre ;
Patka, Peter ;
Van Lieshout, Esther M. M. .
ORTHOPEDICS, 2013, 36 (07) :E849-E858