Establishment of diagnostic reference levels for dental cone beam computed tomography in Tabriz, Iran

被引:0
作者
Mardfar, Sina [1 ,2 ]
Ghaziyani, Mona Fazel [3 ]
Vahdat, Arman Saeedi [4 ]
Khezerloo, Davood [3 ]
机构
[1] Tabriz Univ Med Sci, Student Res Comm, Golgasht St, Tabriz 5166616471, East Azerbaijan, Iran
[2] Tabriz Univ Med Sci, Dept Med Phys, Golgasht St, Tabriz 5166616471, East Azerbaijan, Iran
[3] Tabriz Univ Med Sci, Fac Allied Med Sci, Dept Radiol, Golgasht St, Tabriz 5166616471, East Azerbaijan, Iran
[4] Tabriz Univ Med Sci, Dent Fac, Dept Oral & Maxillofacial Radiol, Golgasht St, Tabriz 5166616471, East Azerbaijan, Iran
关键词
CT; SOFTWARE;
D O I
10.1093/rpd/ncaf063
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Objectives Cone beam computed tomography (CBCT) scans, essential for medical imaging, expose patients to radiation. To ensure safety, this study aimed to establish typical diagnostic reference levels (DRLs) and estimate median organ doses and cancer risks associated with CBCT scans in the Tabriz region, Iran.Results Patient data from 196 individuals undergoing common CBCT procedures were collected. Effective and organ doses were estimated using VirtualDoseCT software. Lifetime attributable risk of cancer incidence was estimated using BEIR VII report. DRL values were established based on gender and indication. Indication based values were 341 mGy.cm2 for implants, 387 mGy.cm2 for lesions, and 342 mGy.cm2 for sinus scans. Effective doses (EDs) were analyzed, yielding values of 30 mu Sv for males and 20 mu Sv for females. Organ doses analysis revealed that salivary glands received the highest dose, while thymus had the lowest in both genders. Lifetime attributable risk of cancer incidence was evaluated and found to be 0.0027 in 100 000 for male patients and 0.0084 in 100 000 for female patients.Conclusions The study highlights the importance of minimizing radiation exposure in CBCT examinations to reduce the risk of cancer and heritable effects. Tailored scan protocols and optimization measures can enhance patient safety by lowering doses. The results offer valuable guidance for dental and maxillofacial imaging practices on radiation doses and DRLs in CBCT examinations.
引用
收藏
页码:641 / 647
页数:7
相关论文
共 20 条
[1]   Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates [J].
Abuzaid, Mohamed M. ;
Elshami, Wiam ;
Jayachandran, Deepa ;
Korappil, Noushad ;
Tekin, Huseyin O. .
TOMOGRAPHY, 2022, 8 (06) :2939-2945
[2]  
[Anonymous], 2012, Annals of the ICRP, V41, DOI [10.1016/j.icrp.2012.02.001, DOI 10.1016/J.ICRP.2012.02.001]
[3]  
AT HDLHG., 2017, COSTAS ZERVIDES QUAL, V39, P67, DOI [10.1016/j.ejmp.2017.05.069, DOI 10.1016/J.EJMP.2017.05.069]
[4]   IAEA survey of dental cone beam computed tomography practice and related patient exposure in nine Central and Eastern European countries [J].
Beganovic, Adnan ;
Ciraj-Bjelac, Olivera ;
Dyakov, Iliya ;
Gershan, Vesna ;
Kralik, Ivana ;
Milatovic, Aleksandra ;
Salat, Dusan ;
Stepanyan, Karapet ;
Vladimirov, Anatoli ;
Vassileva, Jenia .
DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (01)
[5]  
brief TNAri: BEIR VII, 2005, HLTH RISKS EXPOSURE
[6]   Measuring absorbed dose for i-CAT CBCT examinations in child, adolescent and adult phantoms [J].
Choi, E. ;
Ford, N. L. .
DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (06)
[7]   Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland [J].
Deleu, Marine ;
Dagassan, Dorothea ;
Berg, Isabelle ;
Bize, Julie ;
Dula, Karl ;
Lenoir, Vincent ;
Ott, Barbara ;
Ott, Julien G. ;
Verdun, Francis R. ;
Weber, Robert ;
Ziglinas, Panagiotis ;
Zingariello, Cesare ;
Merce, Marta Sans .
DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (06)
[8]   VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients [J].
Ding, Aiping ;
Gao, Yiming ;
Liu, Haikuan ;
Caracappa, Peter F. ;
Long, Daniel J. ;
Bolch, Wesley E. ;
Liu, Bob ;
Xu, X. George .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (14) :5601-5625
[9]   Comparative analysis of traditional radiographs and cone-beam computed tomography volumetric images in the diagnosis and treatment planning of maxillary impacted canines [J].
Haney, Eric ;
Gansky, Stuart A. ;
Lee, Janice S. ;
Johnson, Earl ;
Maki, Koutaro ;
Miller, Arthur J. ;
Huang, John C. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (05) :590-597
[10]   ALARA AND AN INTEGRATED APPROACH TO RADIATION PROTECTION [J].
HENDEE, WR ;
EDWARDS, FM .
SEMINARS IN NUCLEAR MEDICINE, 1986, 16 (02) :142-150