A non-contact metal temperature measurement system based on magnetic field coupling

被引:0
作者
Yang, Hongyan [1 ]
Weng, Wanying [1 ]
Wang, Yunfeng [2 ]
Wu, Jiande [1 ]
He, Xiangning [1 ]
机构
[1] College of Electrical Engineering, Zhejiang University, Hangzhou
[2] Foshan Shunde Midea Electric Heating Appliances Manufacturing Co., Ltd, Foshan
来源
Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument | 2025年 / 46卷 / 01期
关键词
eddy current; magnetic field coupling; non-contact temperature measurement; system modeling;
D O I
10.19650/j.cnki.cjsi.J2413341
中图分类号
学科分类号
摘要
With the continuous advancement of modern science and engineering technology, the importance of metal temperature measurement has become increasingly prominent for ensuring product quality, optimizing production processes, and ensuring safety. However, traditional metal temperature measurement methods often face challenges such as difficulty in online measurement and low measurement accuracy. To address these issues, this study proposes a non-contact metal temperature measurement method based on magnetic field coupling. First, the study analyzes an approximate linear relationship between the real part of the system′s equivalent impedance and temperature, thereby transforming the unmeasurable temperature changes into measurable system impedance. It provides a theoretical foundation for non-contact metal temperature measurement based on magnetic field coupling. Next, an equivalent model of the non-contact metal temperature measurement system is formulated. Its feasibility is evaluated through a three-dimensional finite element simulation using Ansys Maxwell software. Furthermore, the study proposes and compares two different types of eddy current sensors for temperature measurement, highlighting the multi-coil coupled structure for its compact size, high accuracy, and great stability. Based on this, a non-contact metal temperature measurement system using multi-coil coupling is proposed. The system modeling analysis and physical testing are conducted. The experimental results show that the absolute temperature deviation of the non-contact metal temperature measurement system based on the multi-coil coupling model is less than 2℃, confirming the reliability and stability of the system. The system can operate stably without a direct visual path, overcoming the reliance on line-of-sight in traditional non-contact temperature measurement techniques. This advancement significantly improves the system′s performance and applicability, enabling precise, real-time measurement of metal temperature even in complex and obstructed environments. © 2025 Science Press. All rights reserved.
引用
收藏
页码:193 / 202
页数:9
相关论文
共 21 条
[1]  
CUI G, XIONG B, LI ZH G, Et al., Research on local demagnetization characteristics of permanent magnet motor induced by spatial distribution difference of rotor temperature, Proceedings of the CSEE, 44, 6, pp. 2437-2448, (2024)
[2]  
ZHOU J X, ZHENG R CH, HOU H Y., Improved pelican algorithm for optimizing LSTM based temperature prediction of reheating furnace billets, Foreign Electronic Measurement Technology, 42, 5, pp. 174-179, (2023)
[3]  
YAN G J, ZHANG X Y, MEI X Y, Et al., Effect of quenching and tempering on the microstructure and hardness of QTNi4MoV ductile iron prepared by continuous-casting, Transactions of Materials and Heat Treatment, 45, 4, pp. 140-151, (2024)
[4]  
LIU ZH Y, WANG Y H, LIU CH CH, Et al., Optimization design of parameters for transverse flux induction heating device based on multi-island genetic algorithm and response surface method, Transactions of China Electrotechnical Society, 39, 10, pp. 3180-3191, (2024)
[5]  
YAN Y N, LIU ZH K, XU J W, Et al., Temperature decoupled mass sensing based on CBAM-CNN and piezoelectric cantilever beam, Chinese Journal of Scientific Instrument, 45, 4, pp. 113-126, (2024)
[6]  
CHEN M L, XIANG S T, YANG J G., Thermal error modeling method for a direct-drive feed axis under electromagnetic-thermal-flow coupling, Chinese Journal of Scientific Instrument, 44, 12, pp. 34-43, (2023)
[7]  
LI R Y, YANG W Y, XIAO B, Et al., Numerical algorithm for temperature field of coils in high-voltage DC relays, Transactions of China Electrotechnical Society, 33, pp. 444-452, (2018)
[8]  
SONG CH, LI W ZH, LU Y, Et al., Study on the non-contact dense bus temperature measuring system, Electrotechnics Electric, 3, pp. 42-45, (2022)
[9]  
JIA J C, ZHONG Y K, ZHANG Z ZH, Et al., Wafer temperature monitoring technology in integrated circuit manufacturing process, Chinese Journal of Scientific Instrument, 42, 1, pp. 15-29, (2021)
[10]  
YU Y T, DU P AN, LI D SH., Computational methods of coil impedance of eddy current sensor, Chinese Journal of Mechanical Engineering, 2, pp. 210-214, (2007)