Myocardial Perfusion Imaging: Current Nuclear Medicine Methods

被引:0
作者
Shariat, Arya [1 ]
Azam, Saif [2 ]
Koo, Sonya J. [3 ]
Wassef, Heidi [4 ]
Colletti, Patrick M. [5 ]
机构
[1] St Vincent Hosp, Dept Radiol, Worcester, MA USA
[2] Keck Sch Med USC, Dept Radiol, Los Angeles, CA 90033 USA
[3] Vet Adm Greater Los Angeles Healthcare Med Ctr, Dept Radiol, Los Angeles, CA USA
[4] Gen Med Ctr, Radiol, Los Angeles, CA USA
[5] Keck Sch Med USC, USC PET Ctr, Dept Radiol, Radiol & Pharmacol & Pharmaceut Sci, 1510 San Pablo St, Los Angeles, CA 90033 USA
关键词
Myocardial Perfusion; Stress Testing; PET/CT; SPECT; POSITRON-EMISSION-TOMOGRAPHY; FRACTIONAL FLOW RESERVE; CORONARY-ARTERY-DISEASE; BLOOD-PRESSURE RESPONSE; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; SPECT; PET; REGADENOSON; ASSOCIATION;
D O I
10.1097/01.CDR.0001111740.29899.3d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Myocardial perfusion imaging (MPI) plays a crucial role in assessing myocardial perfusion and determining the presence and severity of coronary artery disease. Stress evaluation in MPI can be achieved through exercise or pharmaceutical methods, with exercise stress testing increasing blood flow in normal coronary arteries and pharmaceutical stress testing achieving a similar, although more reliable, effect. PET/CT and cadmium-zinc-telluride SPECT/CT offer improved accuracy compared with SPECT MPI. Different radiotracers used in imaging have their own advantages and disadvantages, which should be considered in specific clinical scenarios.
引用
收藏
页数:8
相关论文
共 59 条
[11]  
Burrell S, 2006, J NUCL MED TECHNOL, V34, P193
[12]   Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans [J].
Chareonthaitawee, P ;
Kaufmann, PA ;
Rimoldi, O ;
Camici, PG .
CARDIOVASCULAR RESEARCH, 2001, 50 (01) :151-161
[13]   Comparison of Coronary CT Angiography, SPECT, PET, and Hybrid Imaging for Diagnosis of Ischemic Heart Disease Determined by Fractional Flow Reserve [J].
Danad, Ibrahim ;
Raijmakers, Pieter G. ;
Driessen, Roel S. ;
Leipsic, Jonathon ;
Raju, Rekha ;
Naoum, Chris ;
Knuuti, Juhani ;
Maki, Maija ;
Underwood, Richard S. ;
Min, James K. ;
Elmore, Kimberly ;
Stuijfzand, Wynand J. ;
van Royen, Niels ;
Tulevski, Igor I. ;
Somsen, Aernout G. ;
Huisman, Marc C. ;
van Lingen, Arthur A. ;
Heymans, Martijn W. ;
van de Ven, Peter M. ;
van Kuijk, Cornelis ;
Lammertsma, Adriaan A. ;
van Rossum, Albert C. ;
Knaapen, Paul .
JAMA CARDIOLOGY, 2017, 2 (10) :1100-1107
[14]   Evaluation of a new multipurpose whole-body CzT-based camera: comparison with a dual-head Anger camera and first clinical images [J].
Desmonts, Cedric ;
Bouthiba, Mohammed Abdeldjalil ;
Enilorac, Blandine ;
Nganoa, Catherine ;
Agostini, Denis ;
Aide, Nicolas .
EJNMMI PHYSICS, 2020, 7 (01)
[15]   Cardiac PET/CT for the Evaluation of Known or Suspected Coronary Artery Disease [J].
Di Carli, Marcelo F. ;
Murthy, Venkatesh L. .
RADIOGRAPHICS, 2011, 31 (05) :1239-1254
[16]   Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation [J].
Dorbala, Sharmila ;
Ananthasubramaniam, Karthik ;
Armstrong, Ian S. ;
Chareonthaitawee, Panithaya ;
DePuey, E. Gordon ;
Einstein, Andrew J. ;
Gropler, Robert J. ;
Holly, Thomas A. ;
Mahmarian, John J. ;
Park, Mi-Ae ;
Polk, Donna M. ;
Russell, Raymond, III ;
Slomka, Piotr J. ;
Thompson, Randall C. ;
Wells, R. Glenn .
JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (05) :1784-1846
[17]   Myocardial perfusion imaging with PET [J].
Driessen, Roel S. ;
Raijmakers, Pieter G. ;
Stuijfzand, Wijnand J. ;
Knaapen, Paul .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (07) :1021-1031
[18]   Comparison of Image Quality, Myocardial Perfusion, and Left Ventricular Function Between Standard Imaging and Single-Injection Ultra-Low-Dose Imaging Using a High-Efficiency SPECT Camera: The MILLISIEVERT Study [J].
Einstein, Andrew J. ;
Blankstein, Ron ;
Andrews, Howard ;
Fish, Mathews ;
Padgett, Richard ;
Hayes, Sean W. ;
Friedman, John D. ;
Qureshi, Mehreen ;
Rakotoarivelo, Harivony ;
Slomka, Piotr ;
Nakazato, Ryo ;
Bokhari, Sabahat ;
Di Carli, Marcello ;
Berman, Daniel S. .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (09) :1430-1437
[19]   Regadenoson Stress Testing: A Comprehensive Review With a Focused Update [J].
Elkholy, Karim O. ;
Hegazy, Omar ;
Okunade, Adeniyi ;
Aktas, Suat ;
Ajibawo, Temitope .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (01)
[20]   Strategies for radiation dose reduction in nuclear cardiology and cardiac computed tomography imaging: a report from the European Association of Cardiovascular Imaging (EACVI), the Cardiovascular Committee of European Association of Nuclear Medicine (EANM), and the European Society of Cardiovascular Radiology (ESCR) [J].
Gimelli, Alessia ;
Achenbach, Stephan ;
Buechel, Ronny R. ;
Edvardsen, Thor ;
Francone, Marco ;
Gaemperli, Oliver ;
Hacker, Marcus ;
Hyafil, Fabien ;
Kaufmann, Philipp A. ;
Lancellotti, Patrizio ;
Nieman, Koen ;
Pontone, Gianluca ;
Pugliese, Francesca ;
Verberne, Hein J. ;
Gutberlet, Matthias ;
Bax, Jeroen J. ;
Neglia, Danilo .