Enzyme-free amplification-enhanced ratiometric fluorescence method for highly sensitive detection of acute myocardial infarction biomarkers

被引:0
作者
Chen, Jingjing [1 ,2 ]
Jia, Xuexia [1 ]
Chen, Ruipeng [1 ]
Zhou, Huanying [1 ]
Wang, Yu [1 ]
Gao, Zhixian [1 ]
机构
[1] Acad Mil Sci, Mil Med Sci Acad, Tianjin Key Lab Risk Assessment & Control Technol, Tianjin 300050, Peoples R China
[2] Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai 200093, Peoples R China
基金
中国国家自然科学基金;
关键词
Acute myocardial infarction; Military medicine; Ratiometric fluorescence; Strand replacement reaction; Triple sensitization; DNA; NANOPARTICLES; PROBES; ABRIN;
D O I
10.1016/j.bios.2025.117527
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A wide range of proteins, including enzymes, hormones, immune factors and regulatory proteins, are essential for a variety of physiological processes. Dysregulation of the levels of specific proteins in organisms is known to adversely affects the human body. Given the pathophysiological significance of cardiac troponin I (cTnI), simple methods for detecting the sensitivity and selectivity of cTnI in biological systems are in high demand and have therefore been extensively explored. Nonetheless, the early detection of low concentrations of cTnI in the human body continues to be a focal point and area of interest in bioassays, due to the low levels and intricate composition of biomarkers in bodily fluids (e.g., blood, sweat, urine, and saliva), which impose rigorous demands on the sensitivity and stability of detection methods. The assay platform is isothermal, homogeneous and has simple experimental conditions without proteases. Using ratiometric fluorescence with built-in self-correction, we achieved low background values and improved the accuracy of the assay results. Our method enhances detection sensitivity by utilizing the cycling of probe X during strand replacement. Triple sensitization was achieved by combining ratiometric fluorescence on the basis of normal strand displacement reaction. In the experiment, the dual sensitization was reflected by the high sensitivity (0.001 ng/mL) and wide linear detection range (0.001 ng/mL similar to 1000 ng/mL) of cTnI in real serum samples. In particular, the snapshots of the simulation process were recorded through accurate simulation calculations and multidimensional characterization analysis, which revealed the changes in the system energy during the simulation process. The sensing platform combines multiple technological advantages, and we are optimistic that the versatility of this research has great potential for application in the fields of early screening and diagnosis and military medical applications.
引用
收藏
页数:13
相关论文
共 52 条
[1]   Visible-Range Multiple-Channel Metal-Shell Rod-Shaped Narrowband Plasmonic Metamaterial Absorber for Refractive Index and Temperature Sensing [J].
Chao, Chung-Ting Chou ;
Kooh, Muhammad Raziq Rahimi ;
Lim, Chee Ming ;
Thotagamuge, Roshan ;
Mahadi, Abdul Hanif ;
Chau, Yuan-Fong Chou .
MICROMACHINES, 2023, 14 (02)
[2]   Susceptible Plasmonic Photonic Crystal Fiber Sensor with Elliptical Air Holes and External-Flat Gold-Coated Surface [J].
Chao, Chung-Ting Chou ;
Kooh, Muhammad Raziq Rahimi ;
Chau, Yuan-Fong Chou ;
Thotagamuge, Roshan .
PHOTONICS, 2022, 9 (12)
[3]   Plasmonics Effects of Nanometal Embedded in a Dielectric Substrate [J].
Chau, Yuan-Fong ;
Jiang, Zheng-Hong .
PLASMONICS, 2011, 6 (03) :581-589
[4]   A comparative study of solid-silver and silver-shell nanodimers on surface plasmon resonances [J].
Chau, Yuan-Fong ;
Yeh, Han-Hsuan .
JOURNAL OF NANOPARTICLE RESEARCH, 2011, 13 (02) :637-644
[5]   Three-dimensional analysis of surface plasmon resonance modes on a gold nanorod [J].
Chau, Yuan-Fong ;
Chen, Min Wei ;
Tsai, Din Ping .
APPLIED OPTICS, 2009, 48 (03) :617-622
[6]   Design of crossing metallic metasurface arrays based on high sensitivity of gap enhancement and transmittance shift for plasmonic sensing applications [J].
Chau, Yuan-Fong Chou ;
Syu, Jhih-Yu ;
Chao, Chung-Ting Chou ;
Chiang, Hai-Pang ;
Lim, Chee Ming .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2017, 50 (04)
[7]   Association between ACEI/D gene polymorphism and coronary artery lesion characteristics in patients with acute myocardial infarction [J].
Cong, D. Tran ;
Hoang, L. Le Gia ;
Duc, M. Do ;
Thanh, T. Thai ;
Van, S. Hoang ;
Quang, B. Truong .
EUROPEAN HEART JOURNAL, 2023, 44 :68-68
[8]   Point-of-care testing of cardiac autonomic function for risk assessment in patients with suspected acute coronary syndromes [J].
Eick, C. ;
Duckheim, M. ;
Groga-Bada, P. ;
Klumpp, N. ;
Mannes, S. ;
Zuern, C. S. ;
Gawaz, M. ;
Rizas, K. D. ;
Bauer, Axel .
CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (09) :686-694
[9]  
FORSTER T, 1949, Z NATURFORSCH A, V4, P321
[10]   Novel polymeric bionanocomposites with catalytic Pt nanoparticles label immobilized for high performance amperometric immunoassay [J].
Fu, Yingchun ;
Li, Penghao ;
Wang, Ting ;
Bu, Lijuan ;
Xie, Qingji ;
Xu, Xiahong ;
Lei, Lihong ;
Zou, Can ;
Chen, Jinhua ;
Yao, Shouzhuo .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (07) :1699-1704