Longitudinal shear behavior of composite slabs with recycled coarse and fine aggregate concrete

被引:0
作者
Bai, Jiongzhuo [1 ]
Geng, Yue [1 ,2 ,3 ,4 ,5 ]
Wang, Yu-Yin [2 ,3 ]
Moy, Charles K. S. [6 ]
Zhang, Huan [2 ,3 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[3] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disaste, Harbin 150090, Peoples R China
[4] Guangdong Prov Key Lab Modern Civil Engn Technol, Guangzhou 510641, Peoples R China
[5] State Key Lab Featured Met Mat & Life Cycle Safety, Nanning 530004, Guangxi, Peoples R China
[6] Xian Jiaotong Liverpool Univ, Dept Civil Engn, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel-concrete composite slab; Recycled aggregate; Loading history; Longitudinal shear; Bearing capacity; STRENGTH; CAPACITY; PERFORMANCE; PREDICTION; RESISTANCE; COLUMNS; BEAMS;
D O I
10.1016/j.cscm.2025.e04842
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-concrete composite slabs, as efficient modern structural components, can incorporate coarse recycled aggregates (CRA) and fine recycled aggregates (FRA) as green alternatives to sand and gravel. However, existing studies have not sufficiently investigated the effects of recycled coarse and fine aggregates as well as loading history on the longitudinal shear capacity of composite slabs, and the applicability of current design methods specified in existing codes for recycled aggregate concrete (RAC) composite slabs has yet to be systematically validated. Therefore, this study systematically investigates recycled aggregates (RAs) composite slabs through experimental testing and numerical modeling. Three full-scale specimens with closed steel decking were tested under varying RAs replacement ratios (coarse/fine aggregates) and sustained load durations (0-500 days). A validated finite element (FE) model incorporating interfacial bond-slip behavior was developed, enabling 136 parametric simulations to assess m-k and partial shear connection (PSC) approaches following Eurocode 4. The results show: (1) RAs incorporation reduces initial stiffness and cracking load by 14.3 % and 27.1 %, respectively, but negligibly affects ultimate shear capacity; (2) 500-day sustained loading enhances shear capacity, stiffness, and cracking load by 9.3 %, 26.3 %, and 16.1 % through concrete aging; (3) Both Eurocode 4 methods demonstrate satisfactory applicability for RAs composite slab design. These results provide critical validation for sustainable composite slab engineering using recycled materials.
引用
收藏
页数:19
相关论文
共 74 条
[1]   Strength and serviceability of continuous composite slabs with deep trapezoidal steel decking and steel fibre reinforced concrete [J].
Abas, F. M. ;
Gilbert, R. I. ;
Foster, S. J. ;
Bradford, M. A. .
ENGINEERING STRUCTURES, 2013, 49 :866-875
[2]   Proposed method for determining the residual mortar content of recycled concrete aggregates [J].
Abbas, Abdelgadir ;
Fathifazl, Gholamreza ;
Burkan Isgor, O. ;
Razaqpur, A.G. ;
Fournier, Benoit ;
Foo, Simon .
Journal of ASTM International, 2008, 5 (01)
[3]   New evaluation and modeling procedure for horizontal shear bond in composite slabs [J].
Abdullah, Redzuan ;
Easterling, W. Samuel .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (04) :891-899
[4]   Prediction of longitudinal shear resistance of steel-concrete composite slabs [J].
Ahmed, Saddam M. ;
Avudaiappan, Siva ;
Sheet, Ikhlas S. ;
Saavedra Flores, Erick I. ;
Pina, Juan C. ;
Yanez, Sergio J. ;
Guzman, Carlos F. .
ENGINEERING STRUCTURES, 2019, 193 :295-300
[5]  
[Anonymous], 2016, JGJ 138-2016
[6]  
[Anonymous], 2008, BS EN 12620:2002+A1:2008
[7]  
[Anonymous], 2017, ANSI/SDI C-2017
[8]  
[Anonymous], 2024, ASTM C33/C33M-24
[9]  
[Anonymous], 2022, GB/T 14685-2022
[10]  
[Anonymous], 2010, Code for design of concrete structures