Dynamic response of the aortic hemodynamic status to endovascular occlusion: A computational fluid dynamics study

被引:0
作者
Li, Zhongyou [1 ,2 ,3 ]
Hou, Anyu [4 ]
Zhang, Jiyang [1 ]
Gao, Fei [5 ]
Yan, Feng [5 ]
Liu, Lingjun [6 ]
Bai, Taoping [1 ]
Zhang, Ming [2 ,3 ]
Jiang, Wentao [1 ,7 ]
机构
[1] Sichuan Univ, Coll Architecture & Environm, Dept Mech Sci & Engn, Chengdu, Peoples R China
[2] Hong Kong Polytech Univ, Fac Engn, Dept Biomed Engn, Hong Kong 999077, Peoples R China
[3] Hong Kong Polytech Univ, Res Inst Sports Sci & Technol, Hong Kong 999077, Peoples R China
[4] Beihang Univ, Beijing Adv Innovat Ctr Biomed Engn, Beijing 100191, Peoples R China
[5] Chengdu Neurotrans Med Technol Co Ltd, Chengdu, Peoples R China
[6] Sichuan Univ, West China Univ Hosp 2, Key Lab Obstet & Gynecol & Pediat Dis & Birth Defe, Minist Educ, Chengdu, Peoples R China
[7] Sichuan Normal Univ, Coll Comp Sci, Chengdu 610101, Peoples R China
关键词
Blood loss; Resuscitative; Occlusion; Pressure; Deformation; BALLOON OCCLUSION; BLOOD-FLOW; HEMORRHAGE; REBOA; TRAUMA;
D O I
10.1016/j.jbiomech.2025.112680
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The hemodynamic status following occlusion is crucial to the efficacy of resuscitative endovascular balloon occlusion of the aorta (REBOA), but existing information on this topic remains limited. This study clarifies the remodeling effects of REBOA on aortic hemodynamics. A geometric model of the aorta, derived from human imaging, is used to simulate various hemorrhagic scenarios (blood loss = 10 %, 25 %, 35 %, and 40 %) through reductions in cardiac output and increases in heart rate. Fluid-structure interaction simulations are performed to explore the relationship between blood pressure, cerebral perfusion, arterial deformation, and blood loss following thoracic aortic occlusion. The results indicated that, when the cerebral blood flow tolerance is reduced by 50 %, the recommended blood loss range for REBOA use is approximately 23.9-30.8 %, corresponding to an initial blood pressure range of 53-71 mmHg. Blood loss < 16.8 % (>90 mmHg) does not necessitate occlusion, whereas blood loss between 16.8 % and 23.9 % (71-90 mmHg) may lead to supraphysiological blood pressure and excessive arterial wall deformation. Blood loss > 30.8 % (<53 mmHg) impedes the achievement of reasonable pressure levels. These findings suggest that REBOA is effective only within a specific range of blood loss. Exceeding or falling below these thresholds can lead to adverse effects, such as hypertension or hemodynamic instability. These findings hold significant clinical relevance for emergency care.
引用
收藏
页数:9
相关论文
共 38 条
[1]   CRIMSON: An open-source software framework for cardiovascular integrated modelling and simulation [J].
Arthurs, Christopher J. ;
Khlebnikov, Rostislav ;
Melville, Alex ;
Marcan, Marija ;
Gomez, Alberto ;
Dillon-Murphy, Desmond ;
Cuomo, Federica ;
Silva Vieira, Miguel ;
Schollenberger, Jonas ;
Lynch, Sabrina R. ;
Tossas-Betancourt, Christopher ;
Iyer, Kritika ;
Hopper, Sara ;
Livingston, Elizabeth ;
Youssefi, Pouya ;
Noorani, Alia ;
Ben Ahmed, Sabrina ;
Nauta, Foeke J. H. ;
van Bakel, Theodorus M. J. ;
Ahmed, Yunus ;
van Bakel, Petrus A. J. ;
Mynard, Jonathan ;
Di Achille, Paolo ;
Gharahi, Hamid ;
Lau, Kevin D. ;
Filonova, Vasilina ;
Aguirre, Miquel ;
Nama, Nitesh ;
Xiao, Nan ;
Baek, Seungik ;
Garikipati, Krishna ;
Sahni, Onkar ;
Nordsletten, David ;
Figueroa, C. Alberto .
PLOS COMPUTATIONAL BIOLOGY, 2021, 17 (05)
[2]   Resuscitative endovascular balloon occlusion of the aorta: the postpartum haemorrhage perspective COMMENT [J].
Brede, Jostein Rodseth ;
Sovik, Edmund ;
Rehn, Marius .
CRITICAL CARE, 2022, 26 (01)
[3]   Use of Resuscitative Endovascular Balloon Occlusion of the Aorta for Proximal Aortic Control in Patients With Severe Hemorrhage and Arrest [J].
Brenner, Megan ;
Teeter, William ;
Hoehn, Melanie ;
Pasley, Jason ;
Hu, Peter ;
Yang, Shiming ;
Romagnoli, Anna ;
Diaz, Jose ;
Stein, Deborah ;
Scalea, Thomas .
JAMA SURGERY, 2018, 153 (02) :130-135
[4]   Clinical use of resuscitative endovascular balloon occlusion of the aorta (REBOA) in civilian trauma systems in the USA, 2019: a joint statement from the American College of Surgeons Committee on Trauma, the American College of Emergency Physicians, the National Association of Emergency Medical Services Physicians and the National Association of Emergency Medical Technicians [J].
Bulger, Eileen M. ;
Perina, Debra G. ;
Qasim, Zaffer ;
Beldowicz, Brian ;
Brenner, Megan ;
Guyette, Frances ;
Rowe, Dennis ;
Kang, Christopher Scott ;
Gurney, Jennifer ;
DuBose, Joseph ;
Joseph, Bellal ;
Lyon, Regan ;
Kaups, Krista ;
Friedman, Vidor E. ;
Eastridge, Brian ;
Stewart, Ronald .
TRAUMA SURGERY & ACUTE CARE OPEN, 2019, 4 (01)
[5]   Hemorrhagic Shock [J].
Cannon, Jeremy W. .
NEW ENGLAND JOURNAL OF MEDICINE, 2018, 378 (04) :370-379
[6]   EFFECT OF HEMORRHAGE ON CARDIAC OUTPUT OF SYMPATHECTOMIZED DOGS [J].
CHIEN, S ;
BILLIG, S .
AMERICAN JOURNAL OF PHYSIOLOGY, 1961, 201 (03) :475-&
[7]   Zone 1 REBOA in a combat DCBI swine model does not worsen brain injury [J].
Cralley, Alexis L. ;
Moore, Ernest E. ;
Fox, Charles J. ;
Kissau, Daniel ;
DeBot, Margot ;
Schaid, Terry R. ;
Mitra, Sanchayita ;
Hom, Patrick ;
Fragoso, Miguel ;
Ghasabyan, Arsen ;
Erickson, Christopher ;
D'Alessandro, Angelo ;
Hansen, Kirk C. ;
Cohen, Mitchell J. ;
Silliman, Christopher C. ;
Sauaia, Angela .
SURGERY, 2022, 172 (02) :751-758
[8]   Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) Zone I Balloon Occlusion Time Affects Spinal Cord Injury in the Nonhuman Primate Model [J].
Eliason, Jonathan L. ;
Myers, Daniel D. ;
Ghosh, Abhijit ;
Morrison, Jonathan J. ;
Mathues, Angela R. ;
Durham, Laura ;
Dunivant, Veronica ;
Gonzalez, Andrew A. ;
Rasmussen, Todd E. .
ANNALS OF SURGERY, 2021, 274 (01) :E54-E61
[9]   A coupled momentum method for modeling blood flow in three-dimensional deformable arteries [J].
Figueroa, C. Alberto ;
Vignon-Clementel, Irene E. ;
Jansen, Kenneth E. ;
Hughes, Thomas J. R. ;
Taylor, Charles A. .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2006, 195 (41-43) :5685-5706
[10]   EFFECTS OF DECREASING ARTERIAL BLOOD-PRESSURE ON CEREBRAL BLOOD-FLOW IN BABOON - INFLUENCE OF SYMPATHETIC NERVOUS-SYSTEM [J].
FITCH, W ;
MACKENZIE, ET ;
HARPER, AM .
CIRCULATION RESEARCH, 1975, 37 (05) :550-557