A Monte Carlo simulation surveying direct DNA damage using different biologically relevant electron energy, absorbed dose, electron tracking and base pair cutoff

被引:0
作者
Ahmed, Mariam M. [2 ]
Ali, M. [1 ]
Moustafa, Mona [1 ]
Khalil, Magdy M. [3 ,4 ]
机构
[1] Helwan Univ, Fac Sci, Dept Phys, Helwan, Cairo, Egypt
[2] Badr Univ Cairo BUC, Sch Biotechnol, Dept Phys, Cairo, Egypt
[3] Badr Univ Cairo BUC, Sch Appl Hlth Sci, Cairo, Egypt
[4] Helwan Univ, Fac Sci, Dept Phys, Med Biophys, Cairo, Egypt
关键词
Monte Carlo simulation; DNA geometry; Geant4-DNA; SSB; DSB; BREAKS; GEOMETRY; MODELS; NUMBER;
D O I
10.1016/j.radphyschem.2025.112940
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
X-ray or heavy ion beams are used in radiotherapy to target cancers and damage DNA. The primary cause of this damage is secondary low energy electrons. This work presents the analysis of DNA molecular damage including single (SSB) and double breaks (DSB) using an atomistic DNA model and track structure physics models. Considerations have been made on the influence of electron energy, electron dose, tracking cutoff as well as base pair cutoff. We simulated a model of atomistic DNA in vacuum, simulating 3 base pairs for each energy which is ranging from 0.04 to 5 keV. The current work showed a significant energy range in the direct interaction between low energy electrons and DNA. By incorporating information about indirect effects, the combination of data allows for the creation of a comprehensive global understanding of the impact of electrons on the biological target. The electron energy range of 100-600 eV has various advantages when used to irradiate cancer cells. This is because energy deposition occurs in dimensions that are like those of DNA strands and nucleosomes, showing that the highest yields of SSB and DSB occurred within the 300-600 eV range, peaking at 400 eV and 500 eV. The most common energy range for SSBs and DSBs was found between 300 and 600 eV. Lower energy and base pair cut-offs lead to greater damage but raising the energy cut-off from 10 to 20 eV greatly lowers the quantity of SSBs and DSBs per electron.
引用
收藏
页数:10
相关论文
共 44 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Comparison of Geant4 electromagnetic physics models against the NIST reference data [J].
Amako, K ;
Guatelli, S ;
Ivanchenko, VN ;
Maire, M ;
Mascialino, B ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Pia, MG ;
Piergentili, M ;
Sasaki, T ;
Urban, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) :910-918
[3]   Impact of DNA Geometry and Scoring on Monte Carlo Track-Structure Simulations of Initial Radiation-Induced Damage [J].
Bertolet, Alejandro ;
Ramos-Mendez, Jose ;
McNamara, Aimee ;
Yoo, Dohyeon ;
Ingram, Samuel ;
Henthorn, Nicholas ;
Warmenhoven, John-William ;
Faddegon, Bruce ;
Merchant, Michael ;
McMahon, Stephen J. ;
Paganetti, Harald ;
Schuemann, Jan .
RADIATION RESEARCH, 2022, 198 (03) :207-220
[4]   Genome Engineering With Zinc-Finger Nucleases [J].
Carroll, Dana .
GENETICS, 2011, 188 (04) :773-782
[5]   The diagnosis and management of nonalcoholic fatty liver disease: Practice guidance from the American Association for the Study of Liver Diseases [J].
Chalasani, Naga ;
Younossi, Zobair ;
Lavine, Joel E. ;
Charlton, Michael ;
Cusi, Kenneth ;
Rinella, Mary ;
Harrison, Stephen A. ;
Brunt, Elizabeth M. ;
Sanyal, Arun J. .
HEPATOLOGY, 2018, 67 (01) :328-357
[6]   Quantification of DNA double-strand breaks using Geant4-DNA [J].
Chatzipapas, Konstantinos P. ;
Papadimitroulas, Panagiotis ;
Obeidat, Mohammad ;
McConnell, Kristen A. ;
Kirby, Neil ;
Loudos, George ;
Papanikolaou, Niko ;
Kagadis, George C. .
MEDICAL PHYSICS, 2019, 46 (01) :405-413
[7]  
Chatzisavvas N., 2021, Annals of Emerging Technologies in Computing (AETiC), V5, P36, DOI [10.33166/AETiC.2021.03.004, DOI 10.33166/AETIC.2021.03.004]
[8]  
Chauvie S., 2004, IEEE S C NUCL SCI 20
[9]  
Cole D.P., 1968, The Demand for Denominations of US Currency, V1914-65
[10]   PDB4DNA: Implementation of DNA geometry from the Protein Data Bank (PDB) description for Geant4-DNA Monte-Carlo simulations [J].
Delage, E. ;
Pham, Q. T. ;
Karamitros, M. ;
Payno, H. ;
Stepan, V. ;
Incerti, S. ;
Maigne, L. ;
Perrot, Y. .
COMPUTER PHYSICS COMMUNICATIONS, 2015, 192 :282-288