共 33 条
Early fault detection method for nuclear power plants based on sparse denoising autoencoder and kernel principal component analysis
被引:0
作者:
Yin, Wenzhe
[1
]
Xia, Hong
[1
]
Huang, Xueying
[1
]
Shan, Longfei
[1
]
Ran, Wenhao
[1
]
Jia, Zhujun
[1
]
机构:
[1] Harbin Engn Univ, Fundamental Sci Nucl Safety & Simulat Technol Lab, Harbin 150001, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Nuclear power plant;
Fault detection;
Kernel principal component analysis;
Sparse denoising autoencoder;
Early fault;
DIAGNOSIS;
CLASSIFICATION;
D O I:
10.1016/j.anucene.2025.111460
中图分类号:
TL [原子能技术];
O571 [原子核物理学];
学科分类号:
0827 ;
082701 ;
摘要:
Effective fault detection technology is of great significance to the safety and economy of nuclear power plants (NPPs). To accurately identify early faults in NPPs, this study proposes a novel fault detection method based on sparse denoising autoencoder (SDAE) and kernel principal component analysis (KPCA). First, the operating data of NPPs is collected by numerous sensors, and the operating parameters are grouped according to physical properties. Then, the corresponding fault detection model is established according to each parameter group, and each detection model consists of the SDAE and KPCA. The case study evaluated four accident scenarios (LOCA, SLBIC, FHAIC, FHAIAB) across two development degrees (0-1 % and 0-0.1 %). The proposed method achieved fault detection rates of 99.07 %, 95.20 %, 99.73 %, and 99.60 % for the 0-1 % degree with zero false alarms. Even for the subtler 0-0.1 % degree, it maintained a 94.84 % average detection rate and no false alarms. Compared to traditional methods, its average fault detection rate was higher than that of PCA and KPCA by 62.9 % and 32.4 % (0-1 % degree), and by 89.5 % and 88 % (0-0.1% degree), demonstrating its potential application value in NPPs.
引用
收藏
页数:14
相关论文