Quantification of residual DTT by high-performance anion-exchange chromatography coupled with pulsed amperometric detection

被引:0
作者
Rajendar, Burki [1 ]
Reddy, M. V. N. Janardhan [1 ]
Adusumilli, Madhavi [1 ]
Matur, Ramesh, V [1 ]
机构
[1] Biol E Ltd, Res & Dev, Plot 1,Phase 2,SP Biotech Pk, Hyderabad 500078, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2025年 / 1259卷
关键词
Vaccines; Viral vaccines; VLPs; Disassembly and reassembly; DTT; HPAEC-PAD; VIRUS-LIKE PARTICLES; DITHIOTHREITOL;
D O I
10.1016/j.jchromb.2025.124609
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
VLP (virus-like particle) have proven to be safer vaccine candidates compared to live-attenuated or inactivated viral vaccines. As part of the manufacturing process of VLP-based vaccines, dithiothreitol (DTT) and other reducing agents are commonly used in the disassembly of VLPs, followed by a subsequent reassembly process for the removal of the added reducing agents. This disassembly and reassembly processes improve VLP integrity, stability and immunoreactivity. In the manufacture of VLPs, it is essential that DTT removal is ensured since it is a highly toxic substance. Residual DTT content has to be monitored throughout the manufacturing process flow of the final pharmaceutical product. The available method for DTT estimation involves chemical derivatization which is complex and may require 100 % derivatization of low levels of DTT. In this study, we report a simple, novel and sensitive method for DTT quantification based on the combination of HPAEC-PAD and an electrochemical detector. The developed method has a linear range from 1 to 10 ng/mL with a limit of quantification of 100 pg. It is cost-effective and more sensitive than current available fluorescent and HPLC-MS-based methods for detecting residual DTT in viral and VLP-based vaccines. This method can be implemented to monitor residual DTT levels in any vaccine or product where DTT is used as a process reagent.
引用
收藏
页数:5
相关论文
共 22 条
[1]  
[Anonymous], 1995, ICH Q2(R1) Guidelines on validation of analytical procedures, ICH Q2(R1) Guidelines on validation of analytical procedures
[2]   Recent Advances in the Use of Plant Virus-Like Particles as Vaccines [J].
Balke, Ina ;
Zeltins, Andris .
VIRUSES-BASEL, 2020, 12 (03)
[3]  
Buonaguro F, 2013, EXPERT REV VACCINES, V12, P99, DOI [10.1586/erv.12.154, 10.1586/ERV.12.154]
[4]   Determination of dithiothreitol in complex protein mixtures by HPLC-MS [J].
Cindric, Mario ;
Cepo, Tina ;
Marinc, Sabina ;
Paskvan, Ivan ;
Mijic, Ivana ;
Bindila, Laura ;
Peter-Katalinic, Jasna .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (20) :3489-3496
[5]   SIMPLIFIED MONITORING OF REDUCED AND OXIDIZED DITHIOTHREITOL USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CLAYCAMP, HG ;
LUDWIG, B .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 422 :239-245
[6]  
Deng F., 2018, J. Immunological Sci, V2, P36, DOI [DOI 10.29245/2578-3009/2018/2.1118, 10.29245/2578-3009/2018/2.1118]
[7]   Monitoring of dithiothreitol clearance by means of micellar electrokinetic chromatography [J].
Glatz, Z ;
Sevcíková, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 770 (1-2) :237-241
[8]   Characterization of an Escherichia coil-derived human papillomavirus type 16 and 18 bivalent vaccine [J].
Gu, Ying ;
Wei, Minxi ;
Wang, Daning ;
Li, Zhihai ;
Xie, Minghui ;
Pan, Huirong ;
Wu, Ting ;
Zhang, Jun ;
Li, Shaowei ;
Xia, Ningshao .
VACCINE, 2017, 35 (35) :4637-4645
[9]   Size-selective downstream processing of virus particles and non-enveloped virus-like particles [J].
Hillebrandt, Nils ;
Hubbuch, Juergen .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
[10]   SEPARATION OF THE OXIDIZED AND REDUCED FORMS OF DITHIOTHREITOL AND 2-MERCAPTOETHANOL BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - APPLICATION OF THE METHOD TO BIOLOGICAL EXTRACTS AND TO THE DETERMINATION OF DISULFIDES [J].
INGEBRETSEN, OC ;
FARSTAD, M .
JOURNAL OF CHROMATOGRAPHY, 1981, 210 (03) :522-526