摘要
The combination of technical advances and the emergence of artificial intelligence in the medical field has given rise to new oxygen saturation (SpO2) measurement processes. In recent years, camera-based estimation of SpO2 has attracted increasing interest. This technique offers an optical way to acquire SpO2 in a very practical way. This review provides an overview of the imaging photoplethysmography-based techniques developed achieve SpO2 prediction from video. A total of 81 articles have been assessed and are included in this review. The results obtained using artificial intelligence-based methods in particular are very promising in view of traditional methods. This suggests that AI-based methods will have an important future role to play medical devices. The prospects are now focused on efforts to improve the robustness and performance of the models, and in fine, to stamp these medical devices in accordance with current standards (CE or FDA) to meet the demands of the medical profession and patient safety.
引用
收藏
页数:14
相关论文
共 99 条
[81]   Wearable Photoplethysmographic Sensors-Past and Present [J].
Tamura, Toshiyo ;
Maeda, Yuka ;
Sekine, Masaki ;
Yoshida, Masaki .
ELECTRONICS, 2014, 3 (02) :282-302
[82]   Non-contact video-based vital sign monitoring using ambient light and auto-regressive models [J].
Tarassenko, L. ;
Villarroel, M. ;
Guazzi, A. ;
Jorge, J. ;
Clifton, D. A. ;
Pugh, C. .
PHYSIOLOGICAL MEASUREMENT, 2014, 35 (05) :807-831
[83]   A Multi-Channel Ratio-of-Ratios Method for Noncontact Hand Video Based SpO2 Monitoring Using Smartphone Cameras [J].
Tian, Xin ;
Wong, Chau-Wai ;
Ranadive, Sushant M. ;
Wu, Min .
IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2022, 16 (02) :197-207
[84]  
Trumpp A., 2016, Curr. Dir. Biomed. Eng., V2, P199
[85]   Contactless SpO2 with an RGB camera: experimental proof of calibrated SpO2 [J].
Van Gastel, Mark ;
Verkruysse, Wim .
BIOMEDICAL OPTICS EXPRESS, 2022, 13 (12) :6791-6802
[86]   Data-Driven Calibration Estimation for Robust Remote Pulse-Oximetry [J].
van Gastel, Mark ;
Verkruysse, Wim ;
de Haan, Gerard .
APPLIED SCIENCES-BASEL, 2019, 9 (18)
[87]   New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring [J].
van Gastel, Mark ;
Stuijk, Sander ;
de Haan, Gerard .
SCIENTIFIC REPORTS, 2016, 6
[88]   Calibration of Contactless Pulse Oximetry [J].
Verkruysse, Wim ;
Bartula, Marek ;
Bresch, Erik ;
Rocque, Mukul ;
Meftah, Mohammed ;
Kirenko, Ihor .
ANESTHESIA AND ANALGESIA, 2017, 124 (01) :136-145
[89]   Fully-automatic camera-based pulse-oximetry during sleep [J].
Vogels, Tom ;
van Gastel, Mark ;
Wang, Wenjin ;
de Haan, Gerard .
PROCEEDINGS 2018 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS (CVPRW), 2018, :1430-1438
[90]   Photoplethysmographic Imaging of Hemodynamics and Two-Dimensional Oximetry [J].
Volkov, I. Yu. ;
Sagaidachnyi, A. A. ;
Fomin, A. V. .
OPTICS AND SPECTROSCOPY, 2022, 130 (07) :452-469