Barrier effect of adjacent deep-buried metro station and its influence on ground settlement induced by foundation pit dewatering

被引:0
作者
Xue, Xiu-li [1 ,2 ]
Xie, Wei-rui [1 ,2 ]
Liao, Huan [1 ,2 ]
Zeng, Chao-feng [1 ,2 ]
Chen, Hong-bo [1 ,2 ]
Xu, Chang-jie [3 ]
Han, Lei [4 ]
机构
[1] Hunan Univ Sci & Technol, Hunan Prov Key Lab Struct Wind Resistance & Vibra, Xiangtan 411201, Hunan, Peoples R China
[2] Hunan Univ Sci & Technol, Sch Civil Engn, Xiangtan 411201, Hunan, Peoples R China
[3] East China Jiaotong Univ, State Key Lab Performance Monitoring Protecting Ra, Nanchang 330013, Jiangxi, Peoples R China
[4] China Construct Eighth Engn Div Corp Ltd, Shanghai 200122, Peoples R China
基金
中国国家自然科学基金;
关键词
foundation pit dewatering; barrier effect; underground structure; foundation pit deformation; pumping test; numerical simulation; DEFORMATION; EXCAVATION; SOIL;
D O I
10.16285/j.rsm.2023.1635
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The existing underground structure blocks groundwater seepage (i.e., water-blocking (WB) effect) and restricts surrounding soil movement (i.e., soil-blocking (SB) effect). This leads to differences in the dewatering-induced behaviors of groundwater and strata compared to scenarios without nearby structures. In this study, a typical metro station was chosen as the nearby underground structure that impedes groundwater and soil flow. Three-dimensional hydro-mechanical numerical models were developed based on an actual foundation pit pumping test to analyze the dewatering-induced responses of groundwater and strata under different WB and SB effects. Factors such as the relative location of the metro station to the excavation, the buried depth of the station structure, and the dewatering depth in the model were considered. The results indicate that the presence of a metro station near the excavation site can either aggravate or restrict dewatering-induced ground settlement, depending on the strength of the SB and WB effects. The distance D between the excavation and the metro station determines the relatively strength of the SB and WB effects, thereby influencing whether the ground settlement is aggravated or restricted. On the other hand, the buried depth H of the station only singularly affects the intensity of the WB or SB effect and could not determine which barrier effect plays the dominant role. In practical engineering applications, it is essential to consider both WB and SB effects based on the proximity and buried depth of the adjacent station structure to effectively assess the dewatering-induced behaviors of groundwater and strata.
引用
收藏
页码:2786 / 2796
页数:11
相关论文
共 21 条
[1]  
Bear J., 1979, Hydraulics of Groundwater
[2]  
[陈仁朋 Chen Renpeng], 2023, [岩土工程学报, Chinese Journal of Geotechnical Engineering], V45, P24
[3]  
[冯国辉 Feng Guohui], 2022, [铁道学报, Journal of the China Railway Society], V44, P132
[4]  
Guan LX, 2023, ROCK SOIL MECH, V44, P3241, DOI 10.16285/j.rsm.2022.1961
[5]  
Lan W, 2022, ROCK SOIL MECH, V43, P2898, DOI 10.16285/j.rsm.2021.1374
[6]   Statistical and hydro-mechanical coupling analyses on groundwater drawdown and soil deformation caused by dewatering in a multi-aquifer-aquitard system [J].
Li, Ming-Guang ;
Chen, Jin-Jian ;
Xia, Xiao-He ;
Zhang, Yang-Qing ;
Wang, Da-Fa .
JOURNAL OF HYDROLOGY, 2020, 589
[7]  
Liu NW, 2019, ROCK SOIL MECH, V40, P1515, DOI 10.16285/j.rsm.2018.0116
[8]  
[刘祥勇 Liu Xiangyong], 2020, [岩土工程学报, Chinese Journal of Geotechnical Engineering], V42, P1331
[9]   Barrier effect of underground structures on aquifers [J].
Pujades, Estanislao ;
Lopez, Ander ;
Carrera, Jesus ;
Vazquez-Sune, Enric ;
Jurado, Anna .
ENGINEERING GEOLOGY, 2012, 145 :41-49
[10]  
[王洪新 Wang Hongxin], 2020, [岩土工程学报, Chinese Journal of Geotechnical Engineering], V42, P1032