Numerical Investigation of Solar Air Heater for Space Heating Application

被引:0
作者
Sutar, S. [1 ]
Rout, S.K. [2 ]
Senapati, J.R. [3 ]
Muduli, K.K. [4 ]
机构
[1] Department of Mechanical Engineering, Bhadrak institute of Engineering and Technology, Orissa, Bhadrak
[2] Department of Mechanical Engineering, C.V. Raman Global University, Bhubaneswar
[3] Department of Mechanical Engineering, National Institute of Technology, Rourkela
[4] School of Mechanical Engineering, Papua New Guinea University of Technology, Lae, Morobe Province
来源
Applied Solar Energy (English translation of Geliotekhnika) | 2024年 / 60卷 / 05期
关键词
air heater; roughened absorber plate; solar energy; thermal enhancement ratio; triangular rib;
D O I
10.3103/S0003701X24602151
中图分类号
学科分类号
摘要
Abstract: Solar power represents a clean and sustainable energy option that boasts widespread accessibility and the potential to drive the establishment of more sustainable systems in the times ahead. The use of solar energy for the use of draying of food, crops, space heating and air ventilation can be consented by a unique device is known as Solar Air Heater (SAH). The utilization of solar energy for activities such as food drying, crop cultivation, space heating, and air ventilation can be facilitated by a unique device known as a SAH. In the present investigation, a compressive investigation of a SAH with right triangular ribs attached to the absorber plate of various orientation with transverse pattern to the flow, investigated numerically. The orientations of the right triangle-shaped ribs are presented individually. Commercially available CFD simulation software, Ansys Fluent, is utilized to solve the equations governing mass, momentum, and energy. The absorber plate is upheld at a heat flux level of 1000 W/m2. The effects of various factors on the performance of SAH, such as the inlet velocity of airflow and rib parameters (pitch and height), are examined. The research investigation includes a diverse set of Reynolds numbers, ranging from 3400 to 19 000. Additionally, the rib pitch ratio varies within the range of 7.33 to 20.66. The discussion has covered the pressure drop attributed to the existence of ribs. To elucidate the fluid flow’s physics, temperature, pressure, and velocity contours are presented. Significant improvement is observed, with an optimized case featuring a rib roughness pitch of 7.33 found for the SAH with triangular ribs, resulting in a Thermal Enhancement Ratio (TER) of 1.89. Non-linear regression analysis has been employed to derive the connections between the Nu and friction factor, demonstrating an accuracy within a 6% error margin. © Allerton Press, Inc. 2024.
引用
收藏
页码:708 / 726
页数:18
相关论文
共 37 条
[1]  
Duffie J.A., Beckman W.A., Solar Engineering of Thermal Processes, (2013)
[2]  
Foster R., Ghassemi M., Cota A., Solar Energy: Renewable Energy and the Environment, (2009)
[3]  
Vliet G.C., Principles of Solar Engineering, (2000)
[4]  
Twidell J., Renewable Energy Resources, (2021)
[5]  
Sawhney J.S., Maithani R., Chamoli S., Experimental investigation of heat transfer and friction factor characteristics of solar air heater using wavy delta winglets, Appl. Therm. Eng, 117, pp. 740-751, (2017)
[6]  
Bopche S.B., Tandale M.S., Experimental investigations on heat transfer and frictional characteristics of a turbulator roughened solar air heater duct, Int. J. Heat Mass Transfer, 52, pp. 2834-2848, (2009)
[7]  
Karmare S.V., Tikekar A.N., Experimental investigation of optimum thermohydraulic performance of solar air heaters with metal rib grits roughness, Sol. Energy, 83, pp. 6-13, (2009)
[8]  
Pandey N., Bajpai V., Experimental investigation of heat transfer augmentation using multiple arcs with gap on absorber plate of solar air heater, Sol. Energy, 134, pp. 314-326, (2016)
[9]  
Lanjewar A., Bhagoria J.L., Sarviya R.M., Experimental study of augmented heat transfer and friction in solar air heater with different orientations of W-Rib roughness, Exp. Therm. Fluid Sci, 35, pp. 986-995, (2011)
[10]  
Alam T., Saini R.P., Saini J.S., Experimental investigation on heat transfer enhancement due to V-shaped perforated blocks in a rectangular duct of solar air heater, Energy Convers. Manage, 81, pp. 374-383, (2014)