共 50 条
Crushing Analysis of Novel Bionic Multi-cell Double Corrugated Tube Under Axial Loading
被引:0
|作者:
Liang, Rui
[1
,2
,3
]
Shi, Qinghang
[4
]
Liu, Longdeng
[1
]
Tuo, Wangjie
[5
]
Qin, Chipeng
[1
]
Bastien, Christophe
[6
]
Mo, Deyun
[1
]
机构:
[1] Guilin Univ Aerosp Technol, Sch Automobile Engn, Guilin 541004, Peoples R China
[2] Wuhan Univ Technol, Hubei Key Lab Adv Technol Automot Components, Wuhan 430070, Peoples R China
[3] Wuhan Univ Technol, Hubei Collaborat Innovat Ctr Automot Components Te, Wuhan 430070, Peoples R China
[4] Shanghai Launch Automot Technol Co Ltd, Shanghai 201600, Peoples R China
[5] Chongqing Ind & Trade Polytech, Sch Automot & Transportat, Chongqing 408000, Peoples R China
[6] Coventry Univ, Ctr Future Transport & Cities, Coventry CV1 2TE, England
来源:
ACTA MECHANICA SOLIDA SINICA
|
2025年
关键词:
Bionic;
Multi-cell;
Corrugated tubes;
Crashworthiness;
Parametric analysis;
FINITE-ELEMENT-ANALYSIS;
ENERGY-ABSORPTION;
CRASHWORTHINESS OPTIMIZATION;
THEORETICAL PREDICTION;
CIRCULAR TUBES;
SQUARE TUBES;
BEHAVIOR;
DESIGN;
PERFORMANCE;
COLLAPSE;
D O I:
10.1007/s10338-025-00609-5
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
Multi-cell structures and corrugated tubes illustrate excellent energy absorption capacities. Besides, bamboo with continuously changing contours demonstrates superior impact-resisting capacities. As a result, a bionic multi-cell double corrugated (BMDC) tube, inspired by Buddha bamboo, is investigated to assess whether it is an ideal energy absorber candidate. Compared to a corrugated tube, a BMDC contains an outer structure, an inner structure, and diaphragms, which are like webs bridging the inner and outer structures. A basic numerical model is correlated using a physical experiment, followed by an investigation of BMDC tubes' energy absorption performance under axial loading, considering thickness and mass effects. Results indicate that the EA, MCF, and SEA of a BMDC containing 5 diaphragms (BMDC-5) with a 1.5 mm thickness can improve their respective responses by 112.89, 112.89, and 83.32% higher compared to a BMDC with no diaphragm (BMDC-0). In addition, the BMDC-5 with 0.156 kg mass generates the highest EA, MCF, and SEA, which is 79.78% higher than a BMDC-0 with the same mass. The parametric analysis illustrates that diaphragms' amplitude and diameter have a decisive influence on energy absorption characteristics. This study emphasizes that BMDC tubes are innovative and practical, possessing excellent energy absorption performance.
引用
收藏
页数:25
相关论文