Comparative analysis of the safety and efficacy of fenestrated pedicle screw with cement and conventional pedicle screw with cement in the treatment of osteoporotic vertebral fractures: A meta-analysis

被引:0
作者
Cao, Li [1 ]
Xu, Hong-Jie [1 ]
Yu, Yi-Kang [2 ]
Tang, Huan-Huan [3 ]
Fang, Bo-Hao [1 ]
Chen, Ke [4 ]
机构
[1] Linping Dist Integrated Tradit & Western Med Hosp, Dept Orthoped & Traumatol, Hangzhou 377799, Peoples R China
[2] Zhejiang Chinese Med Univ, Sch Pharmaceut Sci, Hangzhou 377403, Peoples R China
[3] Bison Xiamen Med Technol Co Ltd, Hangzhou 370072, Peoples R China
[4] Zhejiang Chinese Med Univ, Xinhua Hosp Zhejiang Prov, Affiliated Hosp 2, Dept Orthopaed, Hangzhou 370003, Peoples R China
关键词
Pedicle screw; Internal fixation; Bone cement strengthening; Bone cement leakage; Osteoporosis; Complication; Meta-analysis; INSTRUMENTATION; VERTEBROPLASTY; AUGMENTATION;
D O I
10.1016/j.cjtee.2024.07.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Bone cement-reinforced fenestrated pedicle screws (FPSs) have been widely used in the internal fixation and repair of the spine with osteoporosis in recent years and show significant improvement in fixation strength and stability. However, compared with conventional reinforcement methods, the advantages of bone cement-reinforced FPSs remain undetermined. This article compares the effects of fenestrated and conventional pedicle screws (CPSs) combined with bone cement in the treatment of osteoporosis. Methods: A clinical control study of FPSs and CPSs combined with bone cement reinforcement in osteoporotic vertebral internal fixation was performed using the database PubMed, Embase, Cochrane Library, CNKI, the Wanfang, and the China Biomedical Literature Service System. Two evaluators screened the relevant literature in strict accordance with the inclusion criteria (diagnosis of participants, type of clinical study, treatment with FPS and CPS, and outcome indicators) and exclusion criteria (duplicate literature and missing or incorrect data) and independently conducted data extraction and quality evaluation. Clinical control studies of direct comparison between FPS and CPS combined with bone cement reinforcement in patients who were definitively diagnosed with thoracolumbar fractures or spinal degenerative diseases were included. Quality evaluation was conducted using the Cochrane risk bias evaluation tool for randomized controlled studies and using the Newcastle-Ottawa scale for retrospective case-control studies. RevMan software (version 5.3) was used for the meta-analysis to compare the clinical efficacy, radiological results, and related complications of the 2 methods. Results: A total of 13 articles were included, including 7 randomized controlled studies and 6 retrospective case-control studies. There were 909 patients in these studies, 451 in the FPS and polymethyl methacrylate (FPS & PMMA) group and 458 in the CPS and polymethyl methacrylate (CPS & PMMA) group. The results of the meta-analysis showed that there was no significant difference between the 2 groups in operation time, hospital stay, visual analogue score, Japanese orthopaedic association score, Oswestry disability index score, Cobb angle, vertebral body deformation index and fusion rate (p > 0.05). The mean difference of intraoperative bleeding volume was-10.45, (95% confidence intervals (CI) (-16.92,-3.98), p = 0.002), the mean difference of loss height of the anterior edge of the vertebral body after surgery was-0.69 (95% CI (-0.93,-0.4 4), p < 0.001), and the relative risk (RR) of overall complication rate was 0.43 (95% CI (0.27, 0.68), p < 0.001), including the RR of bone cement leakage rate was 0.57 (95% CI (0.39, 0.85), p = 0.005). The screw loosening rate (RR = 0.26, 95% CI (0.13, 0.54), p < 0.001) of the FPS group was significantly lower than that of the CPS group. Conclusion: The existing clinical evidence shows that compared with the CPS combined with bone cement, the use of FPS repair in the internal fixation of an osteoporotic vertebral body can reduce the amount of intraoperative bleeding, be more conducive to maintaining the height of the vertebral body, and significantly reduce the incidence of postoperative complications such as bone cement leakage and screw loosening. (c) 2024 Chinese Medical Association. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:101 / 112
页数:12
相关论文
共 40 条
[1]   Assessment of different screw augmentation techniques and screw designs in osteoporotic spines [J].
Becker, S. ;
Chavanne, A. ;
Spitaler, R. ;
Kropik, K. ;
Aigner, N. ;
Ogon, M. ;
Redl, H. .
EUROPEAN SPINE JOURNAL, 2008, 17 (11) :1462-1469
[2]  
Bo L, 2019, China Modern Med, V26, P119
[3]   Bone cement cardiac and pulmonary embolism [J].
Cianciulli, Tomas F. ;
Mc Loughlin, Diego E. ;
Morita, Luis A. ;
Saccheri, Maria C. ;
Lax, Jorge A. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (08) :1239-1241
[4]   Safety and efficacy of vertebroplasty for acute painful osteoporotic fractures (VAPOUR): a multicentre, randomised, double-blind, placebo-controlled trial [J].
Clark, William ;
Bird, Paul ;
Gonski, Peter ;
Diamond, Terrence H. ;
Smerdely, Peter ;
McNeil, H. Patrick ;
Schlaphoff, Glen ;
Bryant, Carl ;
Barnes, Elizabeth ;
Gebski, Val .
LANCET, 2016, 388 (10052) :1408-1416
[5]   Surgical treatment of the osteoporotic spine with bone cement-injectable cannulated pedicle screw fixation: technical description and preliminary application in 43 patients [J].
Dai, Fei ;
Liu, Yaoyao ;
Zhang, Fei ;
Sun, Dong ;
Luo, Fei ;
Zhang, Zehua ;
Xu, Jianzhong .
CLINICS, 2015, 70 (02) :114-119
[6]  
Delgado-Fernandez J, 2017, ASIAN SPINE J, V11, P817, DOI 10.4184/asj.2017.11.5.817
[7]   Clinical and Radiological Results of Microsurgical Posterior Lumbar Interbody Fusion and Decompression without Posterior Instrumentation for Lateral Recess Stenosis [J].
Demirayak, Mehmet ;
Sisman, Lokman ;
Turkmen, Faik ;
Efe, Duran ;
Pekince, Oguzhan ;
Goncu, Recep Gani ;
Sever, Cem .
ASIAN SPINE JOURNAL, 2015, 9 (05) :713-720
[8]  
Dhama K, 2020, CLIN MICROBIOL REV, V33, DOI [10.1038/s41432-020-0088-4, 10.1128/CMR.00028-20]
[9]   Computational model predicts risk of spinal screw loosening in patients [J].
Fasser, Marie-Rosa ;
Gerber, Gabriela ;
Passaplan, Caroline ;
Cornaz, Frederic ;
Snedeker, Jess G. ;
Farshad, Mazda ;
Widmer, Jonas .
EUROPEAN SPINE JOURNAL, 2022, 31 (10) :2639-2649
[10]   Comparing the efficacy and safety of cement-augmented fenestrated pedicle screws and conventional pedicle screw in surgery for spinal metastases: a retrospective comparative cohort study [J].
Feng, Qi ;
Zhang, Zibo ;
Wang, Donglai ;
Feng, Jiangang .
TRANSLATIONAL CANCER RESEARCH, 2022, 11 (12) :4397-4408