Glass half full: Non-invasive bladder biosensors for urinary volume monitoring in the neurogenic pediatric population

被引:0
作者
Ly, Serena [1 ]
Kurzrock, Eric A. [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif Sacramento, Davis Sch Med, Sacramento, CA USA
[2] Univ Calif Davis, Dept Urol Surg, Sacramento, CA USA
[3] Univ Calif Sacramento, Davis Childrens Hosp, Sacramento, CA USA
[4] Shriners Hosp Children Northern Calif, Sacramento, CA USA
关键词
neurogenic bladder; biosensor; spina bifida; urine; volume; PRINCIPLES; DESIGN;
D O I
10.1177/18758894241304358
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Purpose The goal was to elucidate and present the current landscape of bladder biosensor technology for urinary volume monitoring in the management of neurogenic bladder. The need for such technology in managing neurogenic bladder in the pediatric population is discussed, as well as the challenges researchers currently face in advancing individual technologies.Methods A literature review including 43 articles discussing bladder biosensor and related technology for continuous urinary volume monitoring was conducted. Articles ranged from original research studies to systematic reviews.Results Various continuous bladder urine volume monitoring devices have been proposed and evaluated. These devices utilize principles of ultrasound, electrical impedance tomography, near infrared spectroscopy, pressure biosensor implantation, microwave radar, and frequency modulated continuous wave radar. While several studies have shown promise in correlating device measurements to bladder urinary volume changes, ultimately researchers have not been able to surmount the challenges of optimizing configuration of device components and the impacts of dynamic position, posture, body habitus, bladder location, and urine biochemical properties that demonstrate high interpersonal variability.Conclusion The need for developing bladder biosensor technology to provide continuous urine volume monitoring in patients with neurogenic bladder remains great. Transitioning from a time-based clean intermittent catheterization approach to a volume-based approach would possibly improve neurogenic bladder patients' quality of life. While technologies face limitations that have stalled translation to clinical practice, there is potential to build upon past work to address current challenges and meet this ever-pressing need.
引用
收藏
页码:420 / 425
页数:6
相关论文
共 40 条
  • [1] CLINICAL USE OF BIOCOMPATIBLE ULTRASONIC BLADDER VOLUME SENSOR
    BRADLEY, WE
    RISE, MT
    FROHRIB, DL
    [J]. UROLOGY, 1979, 14 (03) : 300 - 302
  • [2] Design and Evaluation of Potentiometric Principles for Bladder Volume Monitoring: A Preliminary Study
    Chen, Shih-Ching
    Hsieh, Tsung-Hsun
    Fan, Wen-Jia
    Lai, Chien-Hung
    Chen, Chun-Lung
    Wei, Wei-Feng
    Peng, Chih-Wei
    [J]. SENSORS, 2015, 15 (06) : 12802 - 12815
  • [3] Implantable Bladder Sensors: A Methodological Review
    Dakurah, Mathias Naangmenkpeong
    Koo, Chiwan
    Choi, Wonseok
    Joung, Yeun-Ho
    [J]. INTERNATIONAL NEUROUROLOGY JOURNAL, 2015, 19 (03) : 133 - 141
  • [4] Renal cortical deterioration in children with spinal dysraphism: Analysis of risk factors
    DeLair, Sean M.
    Eandi, Jonathan
    White, Marina J.
    Nguyen, Thuan
    Stone, Anthony R.
    Kurzrock, Eric A.
    [J]. JOURNAL OF SPINAL CORD MEDICINE, 2007, 30 : S30 - S34
  • [5] Neurogenic Bladder
    Dorsher, Peter T.
    McIntosh, Peter M.
    [J]. ADVANCES IN UROLOGY, 2012, 2012
  • [6] BLADDER VOLUME SENSING BY LOCAL DISTENSION MEASUREMENT
    DREHER, RD
    BRADLEY, WE
    TIMM, GW
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1972, BM19 (03) : 247 - &
  • [7] Principles, techniques, and limitations of near infrared spectroscopy
    Ferrari, M
    Mottola, L
    Quaresima, V
    [J]. CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2004, 29 (04): : 463 - 487
  • [8] Fong D.D., 2018, Smart Health, V9-10, P12, DOI [DOI 10.1016/J.SMHL.2018.07, 10.1016/j.smhl.2018.07.014, DOI 10.1016/J.SMHL.2018.07.014]
  • [9] Portable Ultrasound Research System for Use in Automated Bladder Monitoring with Machine-Learning-Based Segmentation
    Fournelle, Marc
    Gruen, Tobias
    Speicher, Daniel
    Weber, Steffen
    Yilmaz, Mehmet
    Schoeb, Dominik
    Miernik, Arkadiusz
    Reis, Gerd
    Tretbar, Steffen
    Hewener, Holger
    [J]. SENSORS, 2021, 21 (19)
  • [10] Fluid volume conductance for determination of bladder volume
    Gill, Bradley C.
    Fletter, Paul C.
    Zaszczurynski, Paul J.
    Perlin, Alfred
    Yachia, Daniel
    Damaser, Margot S.
    [J]. 2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, : 115 - +