Application of a damping switch controller in semiactive electromagnetic seismic isolation systems

被引:0
作者
Lin, Ging-Long [1 ]
Lin, Chi-Chang [2 ,3 ]
Lin, Jian-Zuo [1 ]
机构
[1] Natl Kaohsiung Univ Sci & Technol, Dept Construct Engn, 1 Univ Rd, Kaohsiung, Taiwan
[2] Natl Chung Hsing Univ, Dept Civil Engn, Taichung, Taiwan
[3] Chaoyang Univ Technol, Dept Construct Engn, Taichung, Taiwan
关键词
electromagnetic damping; variable damping; semiactive control; switching control; seismic isolation; near-fault ground motion; shaking table test; VIBRATION CONTROL; ANALYTICAL-MODEL; DESIGN; BEARINGS; DEVICES; PULSES;
D O I
10.1177/10775463251339230
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this study, a practical damping switch control strategy for semiactive electromagnetic seismic isolation systems (SA-EMSIS) was introduced and evaluated. Two configurations were proposed: SA-EMSIS with linear stiffness and SA-EMSIS-NL with nonlinear stiffness. These systems can address the challenges posed by near-fault and far-field ground motions by dynamically activating a high-damping mode when isolation displacement exceeds a predefined threshold. Numerical simulations show that both SA-EMSIS and SA-EMSIS-NL effectively reduce isolation displacement, with SA-EMSIS-NL demonstrating superior performance by achieving significantly lower isolation acceleration. Shaking table experiments validated the feasibility of this control strategy, with close alignment between the experimental and theoretical results. The findings of this study highlight the potential of the proposed systems to improve seismic protection by balancing displacement suppression and acceleration control. This study contributes to the advancement of adaptive seismic isolation technologies and has practical implications for earthquake engineering.
引用
收藏
页数:16
相关论文
共 50 条
[21]   Review of Magnetorheological Damping Systems on a Seismic Building [J].
Lenggana, Bhre Wangsa ;
Ubaidillah, Ubaidillah ;
Imaduddin, Fitrian ;
Choi, Seung-Bok ;
Purwana, Yusep Muslih ;
Harjana, Harjana .
APPLIED SCIENCES-BASEL, 2021, 11 (19)
[22]   Electromagnetic shunt damping for shock isolation of nonlinear vibration isolators [J].
Yan, Bo ;
Ma, Hongye ;
Zhang, Lu ;
Wu, Chuanyu ;
Zhang, Xinong .
JOURNAL OF SOUND AND VIBRATION, 2020, 479
[23]   Application of Subsynchronous Damping Controller to Static Var Compensator [J].
Ghorbani, Hamidreza ;
Moghadam, Davoud Esmail ;
Luna, Alvaro ;
Candela, Jose Ignacio ;
Rodriguez, Pedro .
2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
[24]   Research and application on different types of seismic isolation structures in china [J].
Zhou, FL ;
Yang, Z ;
Huang, XY ;
Tan, P .
PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, :53-59
[25]   An adaptive neural damping controller for HVDC transmission systems [J].
Banaei, M. R. ;
Taheri, N. .
EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2011, 21 (01) :910-923
[26]   STABILITY OF ELASTOMERIC SEISMIC ISOLATION SYSTEMS [J].
Buckle, Ian ;
Monzon, Eric ;
Itani, Ahmad .
Fundamental Research in Structural Engineering: Retrospective and Prospective, Vols 1 and 2, 2016, :23-35
[27]   Definition and Validation of Fast Design Procedures for Seismic Isolation Systems [J].
Furinghetti, Marco .
VIBRATION, 2022, 5 (02) :290-305
[28]   Research on the Performances of Seismic Isolation and Damping in High-rise Buildings [J].
Chen Ron ;
Shiau Yan-Chyuan ;
Tsai Chen-, I .
DISASTER ADVANCES, 2012, 5 (04) :514-519
[29]   Application of isolation systems in the seismic control of cablestayed bridges: a state-of-the-art review [J].
Asgari, B. ;
Osman, S. A. .
LATEST TRENDS ON ENGINEERING MECHANICS, STRUCTURES, ENGINEERING GEOLOGY, 2010, :354-+
[30]   State of the art of the application of seismic isolation and energy dissipation systems to civil structures in Cyprus [J].
Komodromos, P. ;
Phocas, M. C. .
EARTHQUAKE RESISTANT ENGINEERING STRUCTURES VII, 2009, 104 :305-314