Application of a damping switch controller in semiactive electromagnetic seismic isolation systems

被引:0
作者
Lin, Ging-Long [1 ]
Lin, Chi-Chang [2 ,3 ]
Lin, Jian-Zuo [1 ]
机构
[1] Natl Kaohsiung Univ Sci & Technol, Dept Construct Engn, 1 Univ Rd, Kaohsiung, Taiwan
[2] Natl Chung Hsing Univ, Dept Civil Engn, Taichung, Taiwan
[3] Chaoyang Univ Technol, Dept Construct Engn, Taichung, Taiwan
关键词
electromagnetic damping; variable damping; semiactive control; switching control; seismic isolation; near-fault ground motion; shaking table test; VIBRATION CONTROL; ANALYTICAL-MODEL; DESIGN; BEARINGS; DEVICES; PULSES;
D O I
10.1177/10775463251339230
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this study, a practical damping switch control strategy for semiactive electromagnetic seismic isolation systems (SA-EMSIS) was introduced and evaluated. Two configurations were proposed: SA-EMSIS with linear stiffness and SA-EMSIS-NL with nonlinear stiffness. These systems can address the challenges posed by near-fault and far-field ground motions by dynamically activating a high-damping mode when isolation displacement exceeds a predefined threshold. Numerical simulations show that both SA-EMSIS and SA-EMSIS-NL effectively reduce isolation displacement, with SA-EMSIS-NL demonstrating superior performance by achieving significantly lower isolation acceleration. Shaking table experiments validated the feasibility of this control strategy, with close alignment between the experimental and theoretical results. The findings of this study highlight the potential of the proposed systems to improve seismic protection by balancing displacement suppression and acceleration control. This study contributes to the advancement of adaptive seismic isolation technologies and has practical implications for earthquake engineering.
引用
收藏
页数:16
相关论文
共 50 条
[1]   Development of a novel semiactive electromagnetic seismic isolation system [J].
Lin, Ging-Long ;
Chang, Ming-Bin ;
Lin, Jian-Zuo .
ENGINEERING STRUCTURES, 2025, 333
[2]   Theoretical and experimental analysis of an electromagnetic seismic isolation system [J].
Lin, Ging-Long ;
Lin, Chi-Chang ;
Li, Yi-Huan ;
Lin, Tzu-Ting .
ENGINEERING STRUCTURES, 2022, 250
[3]   Fault tolerance of semiactive seismic isolation [J].
Gavin, H ;
Alhan, C ;
Oka, N .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (07) :922-932
[4]   A STFT semiactive controller for base isolated buildings with variable stiffness isolation systems [J].
Narasimhan, S ;
Nagarajaiah, S .
ENGINEERING STRUCTURES, 2005, 27 (04) :514-523
[5]   Experimental investigation of an electromagnetic seismic isolation system with different configurations of inertance [J].
Lin, Ging-Long ;
Chang, Chang-Ching ;
Lin, Chih-Shiuan ;
Lin, Chi-Chang ;
Lin, Tzu-Ting ;
Li, Yi-Huan .
JOURNAL OF SOUND AND VIBRATION, 2025, 595
[6]   Determination of optimal damping parameters for seismic isolation systems [J].
Kovaleva, N. V. ;
Rutman, Yu. L. ;
Davydova, G. V. .
MAGAZINE OF CIVIL ENGINEERING, 2013, 40 (05) :107-115
[7]   Electromagnetic Synchronized Switch Damping for Vibration Control of Flexible Beams [J].
Jung, Jae-Hong ;
Cheng, Tai-Hong ;
Oh, Il-Kwon .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2012, 17 (06) :1031-1038
[8]   A review of adverse effects of damping in seismic isolation [J].
Politopoulos, Ioannis .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2008, 37 (03) :447-465
[9]   Effect of Using High Damping Rubber Bearings for Seismic Isolation of the Buildings [J].
Deringol, Ahmet Hilmi ;
Guneyisi, Esra Mete .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2021, 21 (05) :1698-1722
[10]   Constrained optimal control: an application to semiactive suspension systems [J].
Paschedag, Tina ;
Giua, Alessandro ;
Seatzu, Carla .
INTERNATIONAL JOURNAL OF SYSTEMS SCIENCE, 2010, 41 (07) :797-811