Does organized atrial tachycardia after a pulmonary vein isolation-only procedure portend better outcome of repeat ablation compared to recurrent atrial fibrillation?

被引:0
|
作者
Riesz, Tamas Janos [1 ]
Bencsik, Gabor [1 ]
Saghy, Laszlo [1 ]
Pap, Robert [1 ]
机构
[1] Univ Szeged, Cardiol Ctr, Dept Internal Med, Cardiac Electrophysiol Div, Szeged, Hungary
关键词
atrial fibrillation; organized atrial tachycardia; pulmonary vein isolation; recurrence; CATHETER ABLATION;
D O I
10.1002/joa3.70049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundBetter outcome has been suggested for repeat procedures after atrial fibrillation (AF) ablation, when recurrence presented as organized atrial tachycardia (OAT) compared to recurrent AF. However, this contradicts the finding of more advanced atrial remodeling in patients with OAT recurrence and may be related to iatrogenesis by substrate modification during the index procedure. Therefore, we examined the prognostic significance of the type of recurrent arrhythmia after pulmonary vein isolation (PVI) without additional substrate modification.MethodsWe included 185 patients (88 female, 64 +/- 9 years) undergoing repeat ablation after index PVI for recurrent OAT (24%) or AF (76%). The recurrence rate, arrhythmia-free survival time, and the type of further recurrences were recorded.ResultsThere was no difference in the rate and mean time of arrhythmia-free survival between patients with OAT versus AF recurrence after the first (49% vs. 52%, p = .72 and 51.08 +/- 6.66 vs. 53.37 +/- 4.75 months, p = .54, respectively) and last (60% vs. 58%, p = .80 and 63.2 +/- 7.04 vs. 61.2 +/- 5.32 months, p = .23, respectively) redo procedure. AF occurred in the majority of subsequently recurring patients in both groups. No significant difference was found in the outcome of redo procedures between patients with typical flutter and atypical OAT, but a higher rate of successful rhythm control was observed in those with paroxysmal, as compared to persistent AF recurrence.ConclusionAfter a PVI-only index procedure, recurrent OAT is not associated with a better outcome of redo procedures compared to recurrent AF. After repeat ablations, both groups experience AF as the dominant further recurrence.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Electrophysiological Characteristics of Atrial Tachycardia After Pulmonary Vein Isolation of Atrial Fibrillation
    Satomi, Kazuhiro
    CIRCULATION JOURNAL, 2010, 74 (06) : 1051 - 1058
  • [2] Left Atrial Tachycardia After Pulmonary Vein Isolation for Atrial Fibrillation
    Hashimoto, Kenichi
    Watanabe, Ichiro
    Kofune, Masayoshi
    Ashino, Sonoko
    Okumura, Yasuo
    Ohkubo, Kimie
    Shindo, Atsushi
    Sugimura, Hidezou
    Nakai, Toshiko
    Saito, Satoshi
    JOURNAL OF ARRHYTHMIA, 2005, 21 (05) : 536 - 541
  • [3] Pulmonary vein isolation for atrial fibrillation: Does ablation technique influence outcome?
    Reddy, S. A.
    Nethercott, S. L.
    Khialani, B., V
    Virdee, M. S.
    INDIAN HEART JOURNAL, 2021, 73 (06) : 718 - 724
  • [4] Recurrent Atrial Fibrillation Ablation after Initial Successful Pulmonary Vein Isolation
    Mueller, Julian
    Nentwich, Karin
    Berkovitz, Artur
    Sonne, Kai
    Kozlova, Olena
    Barth, Sebastian
    Deacanu, Alexandru
    Waechter, Christian
    Halbfass, Philipp
    Lehrmann, Heiko
    Deneke, Thomas
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (22)
  • [5] Very Late Relapse of Atrial Fibrillation after Pulmonary Vein Isolation: Incidence and Results of Repeat Ablation
    Fichtner, Stephanie
    Czudnochowsky, Ulrich
    Hessling, Gabriele
    Reents, Tilko
    Estner, Heidi
    Wu, Jinjin
    Jilek, Clemens
    Ammar, Sonia
    Karch, Martin R.
    Deisenhofer, Isabel
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (10): : 1258 - 1263
  • [6] Pulmonary vein tachycardia after pulmonary vein isolation in patients with atrial fibrillation
    Ma, CS
    Dong, JZ
    Liu, XP
    Long, DY
    Fang, DP
    Hu, FL
    Yu, RH
    Tang, RB
    Hao, P
    Lu, CS
    CHINESE MEDICAL JOURNAL, 2006, 119 (07) : 551 - 556
  • [8] Repeat catheter ablation after very late recurrence of atrial fibrillation after pulmonary vein isolation
    Stauffer, Niklas
    Knecht, Sven
    Badertscher, Patrick
    Krisai, Philipp
    Hennings, Elisa
    Serban, Teodor
    Voellmin, Gian
    Osswald, Stefan
    Sticherling, Christian
    Kuhne, Michael
    EUROPACE, 2024, 26 (05):
  • [9] Efficacy of repeat pulmonary vein isolation procedures in patients with recurrent atrial fibrillation
    Callans, DJ
    Gerstenfeld, EP
    Dixit, S
    Zado, E
    Vanderhoff, M
    Ren, JF
    Marchlinski, FE
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (09) : 1050 - 1055
  • [10] Repeat pulmonary vein isolation in patients with atrial fibrillation: low ablation index is associated with increased risk of recurrent arrhythmia
    Kristiansen, Steen B.
    Shafaq, Ajmal
    Tofig, Bawer J.
    Gerdes, Christian
    Jensen, Henrik K.
    Kristensen, Jens
    Parner, Erik T.
    Lukac, Peter
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2021, 55 (01) : 29 - 34