Effects of preparation design on the marginal and internal fit of CAD-CAM overlay restorations: A μCT evaluation

被引:0
作者
Mancuso, Edoardo [1 ]
Forte, Annamaria [1 ]
Maravic, Tatjana [1 ]
Mazzitelli, Claudia [1 ]
Comba, Allegra [2 ]
Baldi, Andrea [2 ]
Fehmer, Vincent [3 ]
Sailer, Irena [3 ]
Scotti, Nicola [2 ]
Mazzoni, Annalisa [1 ]
Breschi, Lorenzo [1 ]
机构
[1] Univ Bologna, Dept Biomed & Neuromotor Sci, Bologna, Italy
[2] Univ Turin, Dept Surg Sci, Turin, Italy
[3] Univ Geneva, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
关键词
IN-VITRO EVALUATION; PARTIAL COVERAGE RESTORATIONS; CERAMIC PARTIAL CROWNS; COMPOSITE RESIN; FRACTURE-RESISTANCE; ADAPTATION; DISCREPANCY; THICKNESS; ACCURACY; STRENGTH;
D O I
10.1016/j.prosdent.2024.12.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem The effects of different finish line designs on the seating accuracy of partial indirect restorations are unclear. Purpose The purpose of this in vitro study was to evaluate the influence of different preparation designs on the marginal and internal discrepancy of lithium disilicate computer-aided design and computer-aided manufacture (CAD-CAM) partial indirect restorations before and after thermomechanical aging by using 3-dimensional (3D) microcomputed tomography (mu CT). Material and methods Forty human molars were divided according to the preparation design and their location relative to the tooth survey line: SO: rounded shoulder occlusal to the survey line; CO: chamfer occlusal to the survey line; SA: rounded shoulder apical to the survey line; CA: chamfer apical to the survey line (n=10). Ceramic onlays were luted using a universal resin cement (RelyX Universal + Scotchbond Universal Plus). The specimens underwent thermomechanical loading in a mastication simulator (1 200 000 mechanical and 5000 thermal cycles). The marginal and internal discrepancy was evaluated with mu CT before and after aging. The volume of cement and internal voids was evaluated with 3-dimensional imaging. The marginal discrepancy (MD), absolute marginal discrepancy (AMD), axial gap (AG), and occlusal gap (OG) were quantified using 2-dimensional analyses. Data were statistically analyzed using a 2-way ANOVA and the Tukey post hoc test (alpha=.05). Results Preparation designs apical to the survey line resulted in a larger volume of cement compared with those occlusal to the survey line (P<.05). No differences were observed in the internal voids among the groups immediately or after aging (P>.05). Both preparation designs and aging had a significant influence on the MD, AMD, AG, and OG (P<.05). Specifically, CB exhibited significantly greater values for AMD, MD, AG, and OG compared with all other preparations (P<.05). CA and SA performed significantly worse than CO and SO in terms of AMD and MD (P<.005). Conclusions Preparations located occlusal to the survey line, particularly CO, demonstrated superior results with respect to both marginal and internal adaptations. CA exhibited the least favorable adaptation among the preparations investigated. Aging had a detrimental impact on the marginal adaptation of the restorations, regardless of the specific preparation design used.
引用
收藏
页码:1055.e1 / 1055.e10
页数:10
相关论文
共 50 条
[41]   Marginal and internal fit of CAD/CAM frameworks in multiple implant-supported restorations: Scanning and milling error analysis [J].
Uribarri, Agurne ;
Bilbao-Uriarte, Eneritz ;
Segurola, Aiora ;
Ugarte, Done ;
Verdugo, Fernando .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) :1062-1072
[42]   Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings [J].
Beuer, Florian ;
Aggstaller, Hans ;
Richter, Juliane ;
Edelhoff, Daniel ;
Gernet, Wolfgang .
QUINTESSENCE INTERNATIONAL, 2009, 40 (03) :243-250
[43]   Marginal fit of CAD-CAM monolithic zirconia crowns fabricated by using cone beam computed tomography scans [J].
Kale, Ediz ;
Cilli, Mesutcan ;
Ozcelik, Tuncer Burak ;
Yilmaz, Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (05) :731-737
[44]   In vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings [J].
Lins, Leonardo ;
Bemfica, Vinicius ;
Queiroz, Celso ;
Canabarro, Antonio .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (03) :205-211
[45]   Comparison of marginal fit between CAD-CAM and hot-press lithium disilicate crowns [J].
Dolev, Eran ;
Bitterman, Yoli ;
Meirowitz, Avi .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (01) :124-128
[46]   Evaluation of the marginal and internal gaps of partially crystallized versus fully crystallized lithium disilicate CAD-CAM crowns [J].
Gumus, Hilal Siriner ;
Aygun, Esma Basak Gul ;
Tuzlali, Mesut ;
Dogan, Nazli Totik .
ODONTOLOGY, 2025,
[47]   In vitro evaluation of marginal and internal adaptation of class II CAD/CAM ceramic restorations with different resinous bases and interface treatments [J].
Sandoval, Maria Jose ;
Rocca, Giovanni Tommaso ;
Krejci, Ivo ;
Mandikos, Michael ;
Dietschi, Didier .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (09) :2167-2177
[48]   Effect of manufacturing trinomial and preparation design on the fabrication and fit accuracy of additively and subtractively manufactured resin-based overlay restorations [J].
Dede, Dogu Omur ;
Zeller, Daniela Karolina ;
Demirel, Munir ;
Al-Johani, Hanan ;
Schimmel, Martin ;
Cakmak, Gulce ;
Yilmaz, Burak ;
Donmez, Mustafa Borga .
JOURNAL OF DENTISTRY, 2025, 157
[49]   Evaluation of the Marginal Fit of a CAD/CAM Zirconia-Based Ceramic Crown System [J].
Baig, Mirza Rustum ;
Al-Tarakemah, Yacoub ;
Abu Kasim, Noor Hayaty ;
Omar, Ridwaan .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (03) :319-329
[50]   Marginal and Internal Discrepancies Related to Margin Design of Ceramic Crowns Fabricated by a CAD/CAM System [J].
Assuncao Souza, Rodrigo Othavio ;
Ozcan, Mutlu ;
Pavanelli, Carlos Augusto ;
Buso, Leonardo ;
Leao Lombardo, Geraldo Henrique ;
Araujo Michida, Silvia Masae ;
Melo Mesquita, Alfredo Mikail ;
Bottino, Marco Antonio .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (02) :94-100