Validity and reliability of inertial measurement units for measuring gait kinematics in older adults across varying fall risk levels and walking speeds

被引:0
作者
Yin, Lulu [1 ]
Chen, Peng [1 ]
Xu, Junkai [2 ]
Gong, Yixue [1 ]
Zhuang, Yifang [1 ]
Chen, Yiming [1 ]
Wang, Lin [3 ,4 ]
机构
[1] Shanghai Univ Sport, Key Lab Exercise & Hlth Sci, Shanghai, Peoples R China
[2] IMU Master Technol Co Ltd, Shanghai, Peoples R China
[3] Shanghai Univ Sport, Sports Med & Rehabil Ctr, 188 Hengren Rd, Shanghai, Peoples R China
[4] Shanghai Shangti Orthopaed Hosp, Shanghai, Peoples R China
关键词
Validity; Reliability; Inertial measurement units; Older adults; TREADMILL WALKING; BALANCE; VALIDATION; BACKWARD; MOBILITY; SYSTEM;
D O I
10.1186/s12877-025-05993-8
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
BackgroundThis study aimed to determine whether the validity and reliability of inertial measurement units (IMUs) in measuring lower extremity joint kinematics differed among different walking velocities and varying fall risk older adults.MethodsForty-five older adults were categorized into low and high fall risk. Lower extremity joint angles during walking were simultaneously measured using inertial measurement units (IMUs) and an optical motion capture (OMC) system across slow, preferred, and fast walking speeds. The Coefficient of Multiple Correlation (CMC) was employed to assess waveform consistency, while systematic error (SE) was calculated to quantify deviations. For discrete kinematic parameters, Pearson's correlation coefficient (r), intra-class correlation coefficients (ICCs), and root mean square error (RMSE) were computed. A two-way analysis of variance utilizing statistical parametric mapping methods was conducted to compare differences in lower extremity joint angles across fall risk categories and varying walking speeds.ResultsFor lower extremity joint waveforms, IMUs demonstrated very good to excellent validity (low fall risk: CMC = 0.872-0.957, SE = 4.8 degrees-9.6 degrees; high fall risk: CMC = 0.894-0.974,SE = 4.5 degrees-6.9 degrees) and reliability (within-raters: low fall risk: CMC = 0.924-0.982, SE = 3.9 degrees-6.5 degrees; high fall risk: CMC = 0.914-0.974, SE = 1.0 degrees-2.5 degrees; between-raters: low fall risk: CMC = 0.953-0.981, SE = 2.2 degrees-5.9 degrees; high fall risk: CMC = 0.903-0.985, SE = 1.7 degrees-2.2 degrees) for joint kinematics in the sagittal plane across various walking velocities in both low and high fall risk individuals. For discrete parameters, r values of peak joint angles and ROM measured by IMUs and OMC system were generally higher in the sagittal plane compared to the frontal and transverse planes. ICC values between within-raters and between-raters comparisons ranged from moderate to excellent, with RMSE values between 2.1 degrees- 8.4 degrees for both within-rater and between-rater comparisons in the sagittal plane. There are significant differences in the joint angles of lower limbs between different fall risk groups and different walking speeds in specific gait cycle intervals.ConclusionIMUs are valid and reliable for measuring joint kinematics both low- and high-fall risk older adults across different walking speeds. However, caution is warranted when interpreting data from the frontal and transverse planes. Additionally, high fall risk individuals had smaller joint angles, while faster walking speeds increased joint angles during specific gait cycles.
引用
收藏
页数:17
相关论文
共 38 条
[1]   Validation of IMU against optical reference and development of open-source pipeline: proof of concept case report in a participant with transfemoral amputation fitted with a Percutaneous Osseointegrated Implant [J].
Ahmed, Kirstin ;
Taheri, Shayan ;
Weygers, Ive ;
Ortiz-Catalan, Max .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2024, 21 (01)
[2]   Assessing falls in the elderly population using G-STRIDE foot-mounted inertial sensor [J].
Alvarez, Marta Neira ;
Ruiz, Antonio R. Jimenez ;
Neira, Guillermo Garcia-Villamil ;
Huertas-Hoyas, Elisabet ;
Cerda, Maria Teresa Espinoza ;
Delgado, Laura Perez ;
Robles, Elena Reina ;
del-Ama, Antonio J. ;
Ruiz-Ruiz, Luisa ;
Garcia-de-Villa, Sara ;
Rodriguez-Sanchez, Cristina .
SCIENTIFIC REPORTS, 2023, 13 (01)
[3]  
[Anonymous], 2023, Leaving no one behind in an ageing world: World social report 2023
[4]  
BERG KO, 1992, CAN J PUBLIC HEALTH, V83, pS7
[5]   Concurrent validity and within-session reliability of gait kinematics measured using an inertial motion capture system with repeated calibration [J].
Berner, Karina ;
Cockcroft, John ;
Morris, Linzette D. ;
Louw, Quinette .
JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2020, 24 (04) :251-260
[6]   Validation of inertial measurement units based on waveform similarity assessment against a photogrammetry system for gait kinematic analysis [J].
Blanco-Coloma, Laura ;
Garcia-Gonzalez, Lucia ;
Sinovas-Alonso, Isabel ;
Torio-alvarez, Silvia ;
Martos-Hernandez, Paula ;
Gonzalez-Exposito, Sara ;
Gil-Agudo, Angel ;
Herrera-Valenzuela, Diana .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
[7]   Risk Assessment and Prevention of Falls in Older Community-Dwelling Adults A Review [J].
Colon-Emeric, Cathleen S. ;
Mcdermott, Cara L. ;
Lee, Deborah S. ;
Berry, Sarah D. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2024, 331 (16) :1397-1406
[8]   Trunk inclination and hip extension mobility, but not thoracic kyphosis angle, are related to 3D-accelerometry based gait alterations and increased fall-risk in older persons [J].
Demarteau, Jeroen ;
Jansen, Bart ;
Van Keymolen, Bart ;
Mets, Tony ;
Bautmans, Ivan .
GAIT & POSTURE, 2019, 72 :89-95
[9]   Comparison of IMU set-ups for the estimation of gait spatio-temporal parameters in an elderly population [J].
Digo, Elisa ;
Panero, Elisa ;
Agostini, Valentina ;
Gastaldi, Laura .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2023, 237 (01) :61-73
[10]   Spatial and temporal gait characteristics of elderly individuals during backward and forward walking with shoes and barefoot [J].
Elboim-Gabyzon, Michal ;
Rotchild, Shira .
GAIT & POSTURE, 2017, 52 :363-366