Comparative Evaluation of Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and X-Ray Fluorescence (XRF) Analysis Techniques for Screening Potentially Toxic Elements in Soil

被引:0
|
作者
Guagliardi, Ilaria [1 ]
Ricca, Nicola [1 ]
Cicchella, Domenico [2 ]
机构
[1] Natl Res Council Italy, Inst Agr & Forest Syst Mediterranean CNR ISAFOM, I-87036 Arcavacata Di Rende, Italy
[2] Univ Sannio, Dept Sci & Technol, I-82100 Benevento, Italy
关键词
inductively coupled plasma mass spectrometry (ICP-MS); X-ray fluorescence (XRF); soil; analytical difference; TRACE-ELEMENTS; TOOL;
D O I
10.3390/toxics13040314
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Soil contamination by potentially toxic elements (PTEs) poses a major environmental concern. The distribution and concentration of these elements can vary significantly in polluted areas, making detailed assessments crucial. A comprehensive analysis is essential to accurately characterise contamination patterns, as a foundation for effective site evaluation and remediation efforts. This study evaluates the effectiveness and reliability of X-ray fluorescence (XRF) and inductively coupled plasma mass spectrometry (ICP-MS) for determining PTEs in soil samples. Statistical analyses reveal significant differences between the two techniques for Sr, Ni, Cr, V, As, and Zn, likely due to variations in detection sensitivity, calibration methods, or matrix effects. Pb exhibits a weaker difference, suggesting a potential, yet statistically insignificant, difference between methods. Correlation analyses indicate a strong linear relationship for Ni and Cr, while Zn and Sr display high variability, limiting direct comparability. Bland-Altman plots highlight systematic biases, particularly for V, where XRF consistently underestimates concentrations compared to ICP-MS. These findings underscore the importance of selecting the appropriate analytical technique based on detection limits, sample characteristics, and measurement reliability. While both methods provide valuable insights for environmental monitoring, carefully considering their limitations is crucial for accurate contamination assessment.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] An overview of recent applications of inductively coupled plasma-mass spectrometry (ICP-MS) in determination of inorganic impurities in drugs and pharmaceuticals
    Rao, R. Nageswara
    Talluri, M. V. N. Kumar
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (01) : 1 - 13
  • [42] Determination of Boron in Coal Using Closed-Vessel Microwave Digestion and Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
    Dai, Shifeng
    Song, Weijiao
    Zhao, Lei
    Li, Xiao
    Hower, James C.
    Ward, Colin R.
    Wang, Peipei
    Li, Tian
    Zheng, Xin
    Seredin, Vladimir V.
    Xie, Panpan
    Li, Qingqian
    ENERGY & FUELS, 2014, 28 (07) : 4517 - 4522
  • [43] Estimation of honey authenticity by multielements characteristics using inductively coupled plasma-mass spectrometry (ICP-MS) combined with chemometrics
    Chudzinska, M.
    Baralkiewicz, D.
    FOOD AND CHEMICAL TOXICOLOGY, 2010, 48 (01) : 284 - 290
  • [44] Guideline of inductively coupled plasma mass spectrometry "ICP-MS": fundamentals, practices, determination of the limits, quality control, and method validation parameters
    Al-Hakkani, Mostafa F.
    SN APPLIED SCIENCES, 2019, 1 (07):
  • [45] Developing a new method for analyzing carbonate-associated phosphate through inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS)
    Liu, Wei
    Zhou, Limin
    Hu, Jundong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (04) : 967 - 974
  • [46] Towards a Standardized Approach for the Geographical Traceability of Plant Foods Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and Principal Component Analysis (PCA)
    Nguyen, Quang Trung
    Nguyen, Thanh Thao
    Le, Van Nhan
    Nguyen, Ngoc Tung
    Truong, Ngoc Minh
    Hoang, Minh Tao
    Pham, Thi Phuong Thao
    Bui, Quang Minh
    FOODS, 2023, 12 (09)
  • [47] Triethylamine-assisted Mg(OH)2 coprecipitation/preconcentration for determination of trace metals and rare earth elements in seawater by inductively coupled plasma mass spectrometry (ICP-MS)
    Arslan, Zikri
    Oymak, Tulay
    White, Jeremy
    ANALYTICA CHIMICA ACTA, 2018, 1008 : 18 - 28
  • [48] Review of the applications of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) to the analysis of biological samples
    Pozebon, Dirce
    Scheffler, Guilherme L.
    Dressler, Valderi L.
    Nunes, Matheus A. G.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (12) : 2204 - 2228
  • [49] Determination of Scandium (Sc), Yttrium (Y), and RareEarth Elements (REEs) in Mafic and Ultramafic Rock Powder by a Modified and Validated Digestion Protocol and Inductively Coupled Plasma - Mass Spectrometry (ICP-MS)
    Tupaz, Carmela Alen J.
    Gregorio, Cynthia Grace C.
    Arcilla, Carlo
    ANALYTICAL LETTERS, 2023, 56 (06) : 932 - 943
  • [50] Determination of total and inorganic mercury in whole blood by cold vapor inductively coupled plasma mass spectrometry (CV ICP-MS) with alkaline sample preparation
    Rodrigues, Jairo L.
    Torres, Daiane P.
    de Oliveira Souza, Vanessa C.
    Batista, Bruno L.
    de Souza, Samuel S.
    Curtius, Adilson J.
    Barbosa, Fernando, Jr.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) : 1414 - 1420