Utilizing Pix2Pix conditional generative adversarial networks to recover missing data in preclinical PET scanner sinogram gaps

被引:0
作者
Karimi, Zahra [1 ]
Saraee, Khadijeh Rezaee Ebrahim [1 ]
Ay, Mohammad Reza [2 ,3 ]
Sheikhzadeh, Peyman [2 ,4 ]
机构
[1] Univ Isfahan, Fac Phys, Esfahan, Iran
[2] Univ Tehran Med Sci, Sch Med, Dept Med Phys & Biomed Engn, Tehran, Iran
[3] Univ Tehran Med Sci TUMS, Adv Med Technol & Equipment Inst AMTEI, Res Ctr Mol & Cellular Imaging RCMCI, Tehran, Iran
[4] Univ Tehran Med Sci, Fac Med, Dept Nucl Med, IKHC, Tehran, Iran
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2025年 / 133卷
关键词
Deep learning; PET scanner; Sinogram; Quantification; IMAGE-RECONSTRUCTION; SPATIAL-RESOLUTION; FILLING METHOD; COMPENSATION; PERFORMANCE; FILTERS; DESIGN;
D O I
10.1016/j.ejmp.2025.104971
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The presence of a gap between adjacent detector blocks in Positron Emission Tomography (PET) scanners introduces a partial loss of projection data, which can degrade the image quality and quantitative accuracy of reconstructed PET images. This study suggests a novel approach for filling missing data from sinograms generated from preclinical PET scanners using a combination of an inpainting method and the Pix2Pix conditional generative adversarial network (cGAN). Materials and methods: Twenty mice and Image Quality (IQ) phantom were scanned by a small animal Xtrim PET scanner, resulting in 7500 raw sinograms used for network training and test datasets. The absence of gap-free sinograms as the target for neural network training was a challenge. This issue was solved by artificially generating gap-free sinograms from the original sinogram. To assess the performance of the proposed approach, the sinograms were reconstructed using the ordered subset expectation maximization (OSEM) algorithm. The overall performance of the proposed network and the quality of the resulting images were quantitatively compared using various metrics, including the root mean squared error (RMSE), structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR). Results: The Pix2Pix cGAN approach achieved an RMSE of 9.34 x 10-4 +/- 5.7 x 10-5 and an SSIM of 99.984 x 10-2 +/- 1.8 x 10-5, considering the corresponding inpainted sinograms as the target. Conclusion: The proposed approach can retrieve missing sinogram data by learning a map derived from the whole sinogram compared to the adjacent pixels, which leads to better quantitative accuracy and improved reconstructed images.
引用
收藏
页数:10
相关论文
共 55 条
  • [11] On the assessment of spatial resolution of PET systems with iterative image reconstruction
    Gong, Kuang
    Cherry, Simon R.
    Qi, Jinyi
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (05) : N193 - N202
  • [12] Image Inpainting
    Guillemot, Christine
    Le Meur, Olivier
    [J]. IEEE SIGNAL PROCESSING MAGAZINE, 2014, 31 (01) : 127 - 144
  • [13] Herraiz JL, 2008, IEEE NUCL SCI S C RE, P4299, DOI [10.1109/NSSMIC.2008.4774234, DOI 10.1109/NSSMIC.2008.4774234]
  • [14] Artificial intelligence guided enhancement of digital PET: scans as fast as CT?
    Hosch, Rene
    Weber, Manuel
    Sraieb, Miriam
    Flaschel, Nils
    Haubold, Johannes
    Kim, Moon-Sung
    Umutlu, Lale
    Kleesiek, Jens
    Herrmann, Ken
    Nensa, Felix
    Rischpler, Christoph
    Koitka, Sven
    Seifert, Robert
    Kersting, David
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (13) : 4503 - 4515
  • [15] GapFill-Recon Net: A Cascade Network for simultaneously PET Gap Filling and Image Reconstruction
    Huang, Yanchao
    Zhu, Huobiao
    Duan, Xiaoman
    Hong, Xiaotong
    Sun, Hao
    Lv, Wenbing
    Lu, Lijun
    Feng, Qianjin
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 208
  • [16] Image-to-Image Translation with Conditional Adversarial Networks
    Isola, Phillip
    Zhu, Jun-Yan
    Zhou, Tinghui
    Efros, Alexei A.
    [J]. 30TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2017), 2017, : 5967 - 5976
  • [17] Jonsson E, 1998, CAM Report, P9848
  • [18] Jung MM, 2018, BEN C ART INT, V9
  • [19] CONSTRAINED FOURIER SPACE METHOD FOR COMPENSATION OF MISSING DATA IN EMISSION COMPUTED-TOMOGRAPHY
    KARP, JS
    MUEHLLEHNER, G
    LEWITT, RM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (01) : 21 - 25
  • [20] An iterative sinogram gap-filling method with object- and scanner-dedicated discrete cosine transform (DCT)-domain filters for high resolution PET scanners
    Kim, Kwangdon
    Lee, Kisung
    Lee, Hakjae
    Joo, Sungkwan
    Kang, Jungwon
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (01) : 59 - 67