perfDSA: Automatic Perfusion Imaging in Cerebral Digital Subtraction Angiography

被引:0
作者
Su, Ruisheng [1 ,2 ]
van der Sluijs, P. Matthijs [2 ]
Marc, Flavius-Gabriel [1 ]
te Nijenhuis, Frank [2 ]
Cornelissen, Sandra A. P. [2 ]
Roozenbeek, Bob [2 ]
van Zwam, Wim H. [3 ]
van der Lugt, Aad [2 ]
Ruijters, Danny [4 ]
Pluim, Josien [1 ]
van Walsum, Theo [2 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Eindhoven, Netherlands
[2] Univ Med Ctr Rotterdam, Dept Radiol & Nucl Med, Erasmus MC, Rotterdam, Netherlands
[3] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, Maastricht, Netherlands
[4] Philips Healthcare, Intervent Xray IXR, Best, Netherlands
关键词
Digital subtraction angiography; Deep learning; Vessel segmentation; Cerebral blood flow; Perfusion; Cerebrovascular disease; ACUTE ISCHEMIC-STROKE; CT;
D O I
10.1007/s11548-025-03359-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeCerebral digital subtraction angiography (DSA) is a standard imaging technique in image-guided interventions for visualizing cerebral blood flow and therapeutic guidance thanks to its high spatio-temporal resolution. To date, cerebral perfusion characteristics in DSA are primarily assessed visually by interventionists, which is time-consuming, error-prone, and subjective. To facilitate fast and reproducible assessment of cerebral perfusion, this work aims to develop and validate a fully automatic and quantitative framework for perfusion DSA.MethodsWe put forward a framework, perfDSA, that automatically generates deconvolution-based perfusion parametric images from cerebral DSA. It automatically extracts the arterial input function from the supraclinoid internal carotid artery (ICA) and computes deconvolution-based perfusion parametric images including cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and Tmax.ResultsOn a DSA dataset with 1006 patients from the multicenter MR CLEAN registry, the proposed perfDSA achieves a Dice of 0.73(+/- 0.21) in segmenting the supraclinoid ICA, resulting in high accuracy of arterial input function (AIF) curves similar to manual extraction. Moreover, some extracted perfusion images show statistically significant associations (P=2.62e-\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$-$$\end{document}5) with favorable functional outcomes in stroke patients.ConclusionThe proposed perfDSA framework promises to aid therapeutic decision-making in cerebrovascular interventions and facilitate discoveries of novel quantitative biomarkers in clinical practice. The code is available at https://github.com/RuishengSu/perfDSA.
引用
收藏
页码:1195 / 1203
页数:9
相关论文
共 50 条
  • [41] Reduction of patient motion artifacts in digital subtraction angiography: Evaluation of a fast and fully automatic technique
    Meijering, EHW
    Niessen, WJ
    Bakker, J
    van der Molen, AJ
    de Kort, GAP
    Lo, RTH
    Mali, WPTM
    Viergever, MA
    RADIOLOGY, 2001, 219 (01) : 288 - 293
  • [42] Automatic detection on intracranial aneurysm from digital subtraction angiography with cascade convolutional neural networks
    Duan, Haihan
    Huang, Yunzhi
    Liu, Lunxin
    Dai, Huming
    Chen, Liangyin
    Zhou, Liangxue
    BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (01)
  • [43] Automatic detection on intracranial aneurysm from digital subtraction angiography with cascade convolutional neural networks
    Haihan Duan
    Yunzhi Huang
    Lunxin Liu
    Huming Dai
    Liangyin Chen
    Liangxue Zhou
    BioMedical Engineering OnLine, 18
  • [44] Digital subtraction cerebral angiography after negative computed tomography angiography findings in non-traumatic subarachnoid hemorrhage
    Catapano, Joshua S.
    Lang, Michael J.
    Koester, Stefan W.
    Wang, Derrick J.
    DiDomenico, Joseph D.
    Fredrickson, Vance L.
    Cole, Tyler S.
    Lee, Jonathan
    Lawton, Michael T.
    Ducruet, Andrew F.
    Albuquerque, Felipe C.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (05) : 526 - 530
  • [45] Role of image fusion combining three-dimensional digital subtraction angiography with magnetic resonance imaging in evaluation of unruptured cerebral aneurysms
    Suzuki, Hidenori
    Shimizu, Shigetoshi
    Maki, Hiroaki
    Maeda, Masayuki
    Sakaida, Hiroshi
    Trousset, Yves
    Taki, Waro
    NEUROLOGICAL RESEARCH, 2007, 29 (01) : 58 - 63
  • [46] Magnetic Resonance Imaging (MRI) and Digital Subtraction Angiography Investigation of Childhood Moyamoya Disease
    Song, Peiji
    Qin, Jing
    Lun, Han
    Qiao, Penggang
    Xie, Anming
    Li, Gongjie
    JOURNAL OF CHILD NEUROLOGY, 2017, 32 (13) : 1027 - 1034
  • [47] Reference Values of Cerebral Artery Diameters of the Anterior Circulation by Digital Subtraction Angiography: A Retrospective Study
    Halama, Dirk
    Merkel, Helena
    Werdehausen, Robert
    Gaber, Khaled
    Schob, Stefan
    Quaschling, Ulf
    Ziganshyna, Svitlana
    Hoffmann, Karl-Titus
    Lindner, Dirk
    Richter, Cindy
    DIAGNOSTICS, 2022, 12 (10)
  • [48] MR digital subtraction angiography in the diagnosis of meningiomas
    Tsuchiya, K
    Katase, S
    Yoshino, A
    Hachiya, J
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 46 (02) : 130 - 138
  • [49] Role of Digital Subtraction Angiography in Diagnosis of Fibromusculardysplasia
    Wang, Christine
    Singla, Animesh
    Kotecha, Krishna
    Nguyen, Daniel
    INDIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 8 : 80 - 82
  • [50] Parametric Color Coding of Digital Subtraction Angiography
    Strother, C. M.
    Bender, F.
    Deuerling-Zheng, Y.
    Royalty, K.
    Pulfer, K. A.
    Baumgart, J.
    Zellerhoff, M.
    Aagaard-Kienitz, B.
    Niemann, D. B.
    Lindstrom, M. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (05) : 919 - 924