perfDSA: Automatic Perfusion Imaging in Cerebral Digital Subtraction Angiography

被引:0
|
作者
Su, Ruisheng [1 ,2 ]
van der Sluijs, P. Matthijs [2 ]
Marc, Flavius-Gabriel [1 ]
te Nijenhuis, Frank [2 ]
Cornelissen, Sandra A. P. [2 ]
Roozenbeek, Bob [2 ]
van Zwam, Wim H. [3 ]
van der Lugt, Aad [2 ]
Ruijters, Danny [4 ]
Pluim, Josien [1 ]
van Walsum, Theo [2 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Eindhoven, Netherlands
[2] Univ Med Ctr Rotterdam, Dept Radiol & Nucl Med, Erasmus MC, Rotterdam, Netherlands
[3] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, Maastricht, Netherlands
[4] Philips Healthcare, Intervent Xray IXR, Best, Netherlands
关键词
Digital subtraction angiography; Deep learning; Vessel segmentation; Cerebral blood flow; Perfusion; Cerebrovascular disease; ACUTE ISCHEMIC-STROKE; CT;
D O I
10.1007/s11548-025-03359-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeCerebral digital subtraction angiography (DSA) is a standard imaging technique in image-guided interventions for visualizing cerebral blood flow and therapeutic guidance thanks to its high spatio-temporal resolution. To date, cerebral perfusion characteristics in DSA are primarily assessed visually by interventionists, which is time-consuming, error-prone, and subjective. To facilitate fast and reproducible assessment of cerebral perfusion, this work aims to develop and validate a fully automatic and quantitative framework for perfusion DSA.MethodsWe put forward a framework, perfDSA, that automatically generates deconvolution-based perfusion parametric images from cerebral DSA. It automatically extracts the arterial input function from the supraclinoid internal carotid artery (ICA) and computes deconvolution-based perfusion parametric images including cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and Tmax.ResultsOn a DSA dataset with 1006 patients from the multicenter MR CLEAN registry, the proposed perfDSA achieves a Dice of 0.73(+/- 0.21) in segmenting the supraclinoid ICA, resulting in high accuracy of arterial input function (AIF) curves similar to manual extraction. Moreover, some extracted perfusion images show statistically significant associations (P=2.62e-\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$-$$\end{document}5) with favorable functional outcomes in stroke patients.ConclusionThe proposed perfDSA framework promises to aid therapeutic decision-making in cerebrovascular interventions and facilitate discoveries of novel quantitative biomarkers in clinical practice. The code is available at https://github.com/RuishengSu/perfDSA.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Cerebral Perfusion Imaging
    Hochberg, Aaron R.
    Young, Geoffrey S.
    SEMINARS IN NEUROLOGY, 2012, 32 (04) : 454 - 465
  • [22] Comparison of computed tomographic angiography with digital subtraction angiography in the diagnosis of cerebral aneurysms: A meta-analysis
    Chappell, ET
    Moure, FC
    Good, MC
    NEUROSURGERY, 2003, 52 (03) : 624 - 630
  • [23] Usefulness of CT angiography for characterizing cerebral arteriovenous malformations presenting as hemorrhage: comparison with digital subtraction angiography
    Zwanzger, C.
    Lopez-Rueda, A.
    Campodonico, D.
    Rosati, S.
    Blasco, J.
    San Roman, L.
    Macho, J.
    RADIOLOGIA, 2020, 62 (05): : 392 - 399
  • [24] Collateral Status in Ischemic Stroke: A Comparison of Computed Tomography Angiography, Computed Tomography Perfusion, and Digital Subtraction Angiography
    Kauw, Frans
    Dankbaar, Jan W.
    Martin, Blake W.
    Ding, Victoria Y.
    Boothroyd, Derek B.
    van Ommen, Fasco
    de Jong, Hugo W. A. M.
    Kappelle, L. Jaap
    Velthuis, Birgitta K.
    Heit, Jeremy J.
    Wintermark, Max
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (06) : 984 - 992
  • [25] Image registration for digital subtraction angiography
    Meijering, EHW
    Zuiderveld, KJ
    Viergever, MA
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 1999, 31 (2-3) : 227 - 246
  • [26] Carbon dioxide digital subtraction angiography
    Barbey, MM
    Farber, A
    Marienhoff, N
    Gmelin, E
    VASA-JOURNAL OF VASCULAR DISEASES, 1999, 28 (04): : 243 - 249
  • [27] Motion compensated digital subtraction angiography
    Hemmendorff, M
    Knutsson, H
    Andersson, MT
    Kronander, T
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 1396 - 1405
  • [28] Image Registration for Digital Subtraction Angiography
    Erik H.W. Meijering
    Karel J. Zuiderveld
    Max A. Viergever
    International Journal of Computer Vision, 1999, 31 : 227 - 246
  • [29] Design of a high-resolution segmentation network for digital subtraction angiography of cerebral vessels
    Cui Y.
    Fu R.
    Zhu J.
    Gao S.
    Chen L.
    Zhang G.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2024, 45 (04): : 786 - 793
  • [30] ERNet: Edge Regularization Network for Cerebral Vessel Segmentation in Digital Subtraction Angiography Images
    Xu, Weijin
    Yang, Huihua
    Shi, Yinghuan
    Tan, Tao
    Liu, Wentao
    Pan, Xipeng
    Deng, Yiming
    Gao, Feng
    Su, Ruisheng
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (03) : 1472 - 1483